Intimal hyperplasia and vascular remodeling after everolimus-eluting and sirolimus-eluting stent implantation in diabetic patients: The randomized diabetes and drug-eluting stent (DiabeDES) IV intravascular ultrasound trial

被引:6
作者
Antonsen, Lisbeth [1 ]
Maeng, Michael [2 ]
Thayssen, Per [1 ]
Christiansen, Evald Hoj [2 ]
Hansen, Knud Norregaard [1 ]
Kaltoft, Anne [2 ]
Hansen, Henrik Steen [1 ]
Thuesen, Leif [2 ]
Lassen, Jens Flensted [2 ]
Jensen, Lisette Okkels [1 ]
机构
[1] Odense Univ Hosp, Dept Cardiol, DK-5000 Odense C, Denmark
[2] Aarhus Univ Hosp, Dept Cardiol, Skejby, Denmark
关键词
PCI; percutaneous coronary intervention; STENT; DIAB; diabetes; AD; coronary artery disease; stent structure; IVUS; intravascular ultrasound; CORONARY-ARTERY LESIONS; NATIONAL HEART; MELLITUS; RESTENOSIS; REVASCULARIZATION; ANGIOPLASTY; ANGIOGRAPHY; OUTCOMES; REGISTRY; LUNG;
D O I
10.1002/ccd.25180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To evaluate the effects of the everolimus-eluting Xience (TM)/Promus (TM) stent (EES) and the sirolimus-eluting Cypher (TM) stent (SES) on intimal hyperplasia (IH) in diabetic patients. Background Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to intimal hyperplasia (IH). Methods In a sub study of the Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated with Percutaneous Coronary Intervention (SORT OUT IV trial), serial intravascular ultrasound (IVUS) 10-month follow-up data were available in 88 patients, including 48 EES and 40 SES treated patients. IVUS endpoints included IH volume, in-stent % volume obstruction and changes in external elastic membrane (EEM) volume. Results Compared with the SES group, IH volume was increased in the EES group [median (interquartile range): 2.8 mm(3) (0.0-12.6) vs. 0.0 mm(3) (0.0-1.1), P = 0.001]. In-stent % volume obstruction was increased in EES compared to SES [median (interquartile range): 1.6% (0.0-8.2) vs. 0.0% (0.0-1.0), P = 0.001]. Peri-stent external elastic membrane (EEM) volume: (post procedure vs. follow-up EES [300 mm(3) (219-491) vs. 307 mm(3) (223-482), P = 0.73] and SES [316 mm(3) (235-399) vs. 323 mm(3) (246-404), P = 0.05]) and peri-stent plaque volume: EES [163 mm(3) (103-273) vs. 184 mm(3) (115-291), P = 0.18] and SES [186 mm(3) (139-248) vs. 175 mm(3) (153-243), P = 0.26]) were unchanged in both groups. In the proximal reference segment a significant increase in plaque area was seen in the EES group only, without vascular remodeling. Conclusion In diabetic patients, EES stent implantation was associated with increased IH volume obstruction without involvement of vascular remodeling. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:864 / 872
页数:9
相关论文
共 50 条
  • [21] Long-term Clinical Outcomes After Everolimus-eluting Stent Implantation in Patients With Acute Myocardial Infarction in Comparison With Sirolimus-eluting Stent
    Hata, Reo
    Kadota, Kazushige
    Yusuke, Hyodo
    Otsuru, Suguru
    Habara, Seiji
    Tada, Takeshi
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    CIRCULATION, 2016, 134
  • [22] Long-Term Clinical Outcomes After Everolimus-and Sirolimus-Eluting Coronary Stent Implantation Final 3-Year Follow-Up of the Randomized Evaluation of Sirolimus-Eluting Versus Everolimus-Eluting Stent Trial
    Shiomi, Hiroki
    Kozuma, Ken
    Morimoto, Takeshi
    Igarashi, Keiichi
    Kadota, Kazushige
    Tanabe, Kengo
    Morino, Yoshihiro
    Akasaka, Takashi
    Abe, Mitsuru
    Suwa, Satoru
    Muramatsu, Toshiya
    Kobayashi, Masakazu
    Dai, Kazuoki
    Nakao, Koichi
    Uematsu, Masaaki
    Tarutani, Yasuhiro
    Fujii, Kenshi
    Simonton, Charles A.
    Kimura, Takeshi
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (03) : 343 - 354
  • [23] Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation
    Hong, Myeong-Ki
    Mintz, Gary S.
    Lee, Cheol Whan
    Park, Duk-Woo
    Choi, Bong-Ryong
    Park, Kyoung-Ha
    Kim, Young-Hak
    Cheong, Sang-Sig
    Song, Jae-Kwan
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    EUROPEAN HEART JOURNAL, 2006, 27 (11) : 1305 - 1310
  • [24] A Randomized Controlled Trial Comparing BioMime Sirolimus-Eluting Stent With Everolimus-Eluting Stent: Two-Year Outcomes of the meriT-V Trial
    Abizaid, Alexandre
    Costa, Ricardo
    Kedev, Sasko
    Kedhi, Elvin
    Talwar, Suneel
    Erglis, Andrejs
    Hlinomaz, Ota
    Masotti, Monica
    Fath-Ordoubadi, Farzin
    Milewski, Krzysztof
    Lemos, Pedro
    Botelho, Roberto
    Ijsselmuiden, Alexander
    Koolen, Jacques
    Kala, Petr
    Janssens, Luc
    Chandra, Udita
    CARDIOLOGY RESEARCH, 2023, 14 (04) : 291 - 301
  • [25] Long-term Clinical Outcomes After Everolimus-eluting Stent Implantation in Patients With Acute Myocardial Infarction in Comparison With Sirolimus-eluting Stent
    Hata, Reo
    Kadota, Kazushige
    Yusuke, Hyodo
    Otsuru, Suguru
    Habara, Seiji
    Tada, Takeshi
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    CIRCULATION, 2016, 134
  • [26] Predictors for very late stent thrombosis after drug-eluting stent implantation in diabetic patients
    Vouidris, Vassilis
    Kariofillis, Panagiotis
    Thomopoulou, Sophia
    Patsilinakos, Sotiris
    Manginas, Athanasios
    Spargias, Constantinos
    Pavlides, Gregory
    Cokkinos, Dennis V.
    EUROINTERVENTION, 2009, 4 (04) : 485 - 491
  • [27] Integrity of stent polymer layer after drug-eluting stent implantation: In vivo comparison of sirolimus-, paclitaxel-, zotarolimus- and everolimus-eluting stents
    Watanabe T.
    Fujita M.
    Awata M.
    Iida O.
    Okamoto S.
    Ishihara T.
    Uematsu M.
    Cardiovascular Intervention and Therapeutics, 2014, 29 (1) : 4 - 10
  • [28] Two-year Clinical Outcomes of Patients with Long Segments Drug-Eluting Stents: Comparison of Sirolimus-Eluting Stent with Paclitaxel-Eluting Stent
    Kim, Ung
    Lee, Sang-Hee
    Hong, Geu-Ru
    Park, Jong-Seon
    Shin, Dong-Gu
    Kim, Young-Jo
    Jang, Jae-Sik
    Yang, Tae-Hyun
    Kim, Dae-Kyeong
    Kim, Dong-Soo
    Kim, Dong-Kie
    Seol, Sang-Hoon
    Kim, Doo-Il
    Cho, Yoon-Kyung
    Kim, Hyung-Seop
    Nam, Chang-Wook
    Hur, Seung-Ho
    Kim, Kwon-Bae
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2011, 26 (10) : 1299 - 1304
  • [29] Neointimal hyperplasia persists at six months after sirolimus-eluting stent implantation in diabetic porcine
    Zhang, Qi
    Lu, Lin
    Pu, LiJin
    Zhang, RuiYan
    Shen, Jie
    Zhu, ZhengBing
    Hu, Jian
    Yang, ZhenKun
    Chen, QiuJin
    Shen, WeiFeng
    CARDIOVASCULAR DIABETOLOGY, 2007, 6
  • [30] Comparison of Efficacy and Safety between Sirolimus, Paclitaxel, Everolimus-Eluting Stent and SeQuent™ Please, a Drug-Eluting Balloon on the Outcome of Patients with Diffuse In-Stent Restenosis after Bare Metal Stent Implantation
    Nakamura, Sunao
    Ogawa, Hisao
    Bae, Jang-Ho
    Cahyadi, Yeo H.
    Udayachalerm, Wasan
    Tresukosol, Damras
    Tansuphaswadikul, Sudaratana
    CIRCULATION, 2010, 122 (21)