Fault detection in multi-sensor networks based on multivariate time-series models and orthogonal transformations

被引:78
作者
Serdio, Francisco [1 ]
Lughofer, Edwin [1 ]
Pichler, Kurt [2 ]
Buchegger, Thomas [2 ]
Pichler, Markus [2 ]
Efendic, Hajrudin [3 ]
机构
[1] Johannes Kepler Univ Linz, Dept Knowledge Based Math Syst, Linz, Austria
[2] Austrian Competence Ctr Mechatron, Linz, Austria
[3] Johannes Kepler Univ Linz, Inst Design & Control Mechatron Syst, Linz, Austria
关键词
Residual-based fault detection; System identification; Vectorized time-series models (types of); Multivariate orthogonal space transformations; On-line incremental residual analysis; PARTIAL LEAST-SQUARES; FUZZY-SYSTEMS; DIAGNOSIS; CLASSIFIER; ALGORITHMS; COMPONENTS;
D O I
10.1016/j.inffus.2014.03.006
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We introduce the usage of multivariate orthogonal space transformations and vectorized time-series models in combination with data-driven system identification models to achieve an enhanced performance of residual-based fault detection in condition monitoring systems equipped with multi-sensor networks. Neither time-consuming annotated samples nor fault patterns/models need to be available, as our approach is solely based on on-line recorded data streams. The system identification step acts as a fusion operation by searching for relations and dependencies between sensor channels measuring the state of system variables. We therefore apply three different vectorized time-series variants: (i) non-linear finite impulse response models (NFIR) relying only on the lagged input variables, (ii) non-linear output error models (NOE), also including the lags of the own predictions and (iii) non-linear Box-Jenkins models (NBJ) which include the lags of the predictions errors as well. The use of multivariate orthogonal space transformations allows to produce more compact and accurate models due to an integrated dimensionality (noise) reduction step. Fault detection is conducted based on finding anomalies (untypical occurrences) in the temporal residual signal in incremental manner. Our experimental results achieved on four real-world condition monitoring scenarios employing multi-sensor network systems demonstrate that the Receiver Operating Characteristic (ROC) curves are improved over those ones achieved with native static models (w/o lags, w/o transformations) by about 20-30%. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:272 / 291
页数:20
相关论文
共 56 条
[1]   Evolving fuzzy classifiers using different model architectures [J].
Angelov, P. ;
Lughofer, E. ;
Zhou, X. .
FUZZY SETS AND SYSTEMS, 2008, 159 (23) :3160-3182
[2]   An approach to model-based fault detection in industrial measurement systems with application to engine test benches [J].
Angelov, P. ;
Giglio, V. ;
Guardiola, C. ;
Lughofer, E. ;
Lujan, J. M. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (07) :1809-1818
[3]  
[Anonymous], 2003, Fuzzy Model Identification for Control
[4]  
[Anonymous], METALS MINING
[5]  
[Anonymous], 2002, Principal components analysis
[6]  
[Anonymous], INF SCI
[7]  
[Anonymous], 2006, PATTERN RECOGN
[8]  
[Anonymous], P ASME 2012 INT MECH
[9]  
[Anonymous], 2006, Statistics: Methods and Applications
[10]   Nonlinear PLS modeling with fuzzy inference system [J].
Bang, YH ;
Yoo, CK ;
Lee, IB .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2002, 64 (02) :137-155