Continuous Real Time Breath Gas Monitoring in the Clinical Environment by Proton-Transfer-Reaction-Time-of-Flight-Mass Spectrometry

被引:122
作者
Trefz, Phillip [1 ]
Schmidt, Markus [1 ]
Oertel, Peter [1 ]
Obermeier, Juliane [1 ]
Brock, Beate [1 ]
Kamysek, Svend [1 ]
Dunkl, Juergen [2 ]
Zimmermann, Ralf [3 ,4 ]
Schubert, Jochen K. [1 ]
Miekisch, Wolfram [1 ]
机构
[1] Univ Med Ctr Rostock, Dept Anaesthesia & Intens Care, D-18057 Rostock, Germany
[2] Ionicon Analyt GmbH, A-6020 Innsbruck, Austria
[3] Univ Rostock, Joint Mass Spectrometry Ctr, Chair Analyt Chem, D-18059 Rostock, Germany
[4] Helmholtz Zentrum Munchen, Cooperat Grp Comprehens Mol Analyt, Joint Mass Spectrometry Ctr, D-85764 Neuherberg, Germany
关键词
VOLATILE ORGANIC-COMPOUNDS; MECHANICALLY VENTILATED PATIENTS; SOLID-PHASE MICROEXTRACTION; CRITICALLY-ILL PATIENTS; MULTIBED SORPTION TRAP; ELECTROSPRAY-IONIZATION; EXHALED BREATH; MS; SEVOFLURANE; CHROMATOGRAPHY;
D O I
10.1021/ac402298v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Analysis of volatile organic compounds (VOCs) in breath holds great promise for noninvasive diagnostic applications. However, concentrations of VOCs in breath may change quickly, and actual and previous uptakes of exogenous substances, especially in the clinical environment, represent crucial issues. We therefore adapted proton-transfer-reaction-time-of-flight-mass spectrometry for real time breath analysis in the clinical environment. For reasons of medical safety, a 6 m long heated silcosteel transfer line connected to a sterile mouth piece was used for breath sampling from spontaneously breathing volunteers and mechanically ventilated patients. A time resolution of 200 ms was applied. Breath from mechanically ventilated patients was analyzed immediately after cardiac surgery. Breath from 32 members of staff was analyzed in the post anesthetic care unit (PACU). In parallel, room air was measured continuously over 7 days. Detection limits for breath-resolved real time measurements were in the high pptV/low ppbV range. Assignment of signals to alveolar or inspiratory phases was done automatically by a matlab-based algorithm. Quickly and abruptly occurring changes of patients' clinical status could be monitored in terms of breath-to-breath variations of VOC (e.g. isoprene) concentrations. In the PACU, room air concentrations mirrored occupancy. Exhaled concentrations of sevoflurane strongly depended on background concentrations in all participants. In combination with an optimized inlet system, the high time and mass resolution of PTR-ToF-MS provides optimal conditions to trace quick changes of breath VOC profiles and to assess effects from the clinical environment.
引用
收藏
页码:10321 / 10329
页数:9
相关论文
共 50 条
  • [21] First observation of a potential non-invasive breath gas biomarker for kidney function
    Kohl, Ingrid
    Beauchamp, Jonathan
    Cakar-Beck, Ferguel
    Herbig, Jens
    Dunkl, J.
    Tietje, Olaf
    Tiefenthaler, Martin
    Boesmueller, Claudia
    Wisthaler, Armin
    Breitenlechner, Martin
    Langebner, Stephan
    Zabernigg, August
    Reinstaller, Florian
    Winkler, Klaus
    Gutmann, Rene
    Hansel, Armin
    [J]. JOURNAL OF BREATH RESEARCH, 2013, 7 (01)
  • [22] Lindstrom AB, 1997, ENVIRON HEALTH PERSP, V105, P636
  • [23] Direct Analysis of Fatty Acid Vapors in Breath by Electrospray Ionization and Atmospheric Pressure Ionization-Mass Spectrometry
    Martinez-Lozano, Pablo
    de la Mora, Juan Fernandez
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (21) : 8210 - 8215
  • [24] Diagnostic potential of breath analysis - focus on volatile organic compounds
    Miekisch, W
    Schubert, JK
    Noeldge-Schomburg, GFE
    [J]. CLINICA CHIMICA ACTA, 2004, 347 (1-2) : 25 - 39
  • [25] Assessment of propofol concentrations in human breath and blood by means of HS-SPME-GC-MS
    Miekisch, Wolfram
    Fuchs, Patricia
    Kamysek, Svend
    Neumann, Christine
    Schubert, Jochen K.
    [J]. CLINICA CHIMICA ACTA, 2008, 395 (1-2) : 32 - 37
  • [26] Automated Needle Trap Heart-Cut GC/MS and Needle Trap Comprehensive Two-Dimensional GC/TOF-MS for Breath Gas Analysis in the Clinical Environment
    Mieth, Maren
    Schubert, Jochen K.
    Groeger, Thomas
    Sabel, Bastian
    Kischkel, Sabine
    Fuchs, Patricia
    Hein, Dietmar
    Zimmermann, Ralf
    Miekisch, Wolfram
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (06) : 2541 - 2551
  • [27] Rapid "Breath-Print" of Liver Cirrhosis by Proton Transfer Reaction Time-of-Flight Mass Spectrometry. A Pilot Study
    Morisco, Filomena
    Aprea, Eugenio
    Lembo, Vincenzo
    Fogliano, Vincenzo
    Vitaglione, Paola
    Mazzone, Giovanna
    Cappellin, Luca
    Gasperi, Flavia
    Masone, Stefania
    De Palma, Giovanni Domenico
    Marmo, Riccardo
    Caporaso, Nicola
    Biasioli, Franco
    [J]. PLOS ONE, 2013, 8 (04):
  • [28] Single photon ionization time-of-flight mass spectrometry with a pulsed electron beam pumped excimer VUV lamp for on-line gas analysis:: Setup and first results on cigarette smoke and human breath
    Mühlberger, F
    Streibel, T
    Wieser, J
    Ulrich, A
    Zimmermann, R
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (22) : 7408 - 7414
  • [29] Dont waste your breath
    Mukhopadhyay, R
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (15) : 273A - 276A
  • [30] Mukhopadhyay Rajendrani, 2007, Anal Chem, V79, P2610, DOI 10.1021/ac071898e