Continuous Real Time Breath Gas Monitoring in the Clinical Environment by Proton-Transfer-Reaction-Time-of-Flight-Mass Spectrometry

被引:121
|
作者
Trefz, Phillip [1 ]
Schmidt, Markus [1 ]
Oertel, Peter [1 ]
Obermeier, Juliane [1 ]
Brock, Beate [1 ]
Kamysek, Svend [1 ]
Dunkl, Juergen [2 ]
Zimmermann, Ralf [3 ,4 ]
Schubert, Jochen K. [1 ]
Miekisch, Wolfram [1 ]
机构
[1] Univ Med Ctr Rostock, Dept Anaesthesia & Intens Care, D-18057 Rostock, Germany
[2] Ionicon Analyt GmbH, A-6020 Innsbruck, Austria
[3] Univ Rostock, Joint Mass Spectrometry Ctr, Chair Analyt Chem, D-18059 Rostock, Germany
[4] Helmholtz Zentrum Munchen, Cooperat Grp Comprehens Mol Analyt, Joint Mass Spectrometry Ctr, D-85764 Neuherberg, Germany
关键词
VOLATILE ORGANIC-COMPOUNDS; MECHANICALLY VENTILATED PATIENTS; SOLID-PHASE MICROEXTRACTION; CRITICALLY-ILL PATIENTS; MULTIBED SORPTION TRAP; ELECTROSPRAY-IONIZATION; EXHALED BREATH; MS; SEVOFLURANE; CHROMATOGRAPHY;
D O I
10.1021/ac402298v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Analysis of volatile organic compounds (VOCs) in breath holds great promise for noninvasive diagnostic applications. However, concentrations of VOCs in breath may change quickly, and actual and previous uptakes of exogenous substances, especially in the clinical environment, represent crucial issues. We therefore adapted proton-transfer-reaction-time-of-flight-mass spectrometry for real time breath analysis in the clinical environment. For reasons of medical safety, a 6 m long heated silcosteel transfer line connected to a sterile mouth piece was used for breath sampling from spontaneously breathing volunteers and mechanically ventilated patients. A time resolution of 200 ms was applied. Breath from mechanically ventilated patients was analyzed immediately after cardiac surgery. Breath from 32 members of staff was analyzed in the post anesthetic care unit (PACU). In parallel, room air was measured continuously over 7 days. Detection limits for breath-resolved real time measurements were in the high pptV/low ppbV range. Assignment of signals to alveolar or inspiratory phases was done automatically by a matlab-based algorithm. Quickly and abruptly occurring changes of patients' clinical status could be monitored in terms of breath-to-breath variations of VOC (e.g. isoprene) concentrations. In the PACU, room air concentrations mirrored occupancy. Exhaled concentrations of sevoflurane strongly depended on background concentrations in all participants. In combination with an optimized inlet system, the high time and mass resolution of PTR-ToF-MS provides optimal conditions to trace quick changes of breath VOC profiles and to assess effects from the clinical environment.
引用
收藏
页码:10321 / 10329
页数:9
相关论文
共 50 条
  • [1] ONLINE ANALYSIS OF BREATH BY PROTON TRANSFER REACTION TIME OF FLIGHT MASS SPECTROMETRY IN CIRRHOTIC PATIENTS
    Lembo, V.
    Aprea, E.
    Fogliano, V.
    Vitaglione, P.
    Mazzone, G.
    Loperto, I.
    Cappellin, L.
    Gasperi, F.
    Biasioli, F.
    Morisco, F.
    Caporaso, N.
    JOURNAL OF HEPATOLOGY, 2013, 58 : S91 - S91
  • [2] Real-time metabolic monitoring with proton transfer reaction mass spectrometry
    Winkler, Klaus
    Herbig, Jens
    Kohl, Ingrid
    JOURNAL OF BREATH RESEARCH, 2013, 7 (03)
  • [3] Proton transfer reaction time-of-flight mass spectrometry: A good prospect for diagnostic breath analysis?
    Blake, RS
    Whyte, C
    Monks, PS
    Ellis, AM
    Breath Analysis: for Clinical Diagnosis and ATherapeutic Monitoring, 2005, : 45 - 51
  • [4] Investigating the reproducibility of real time breath measurements using proton transfer reaction - time of flight - mass spectrometry for breath of volatile organic compounds in COPD Patients.
    Bryant, Luke
    Carr, Liesl
    Yousuf, Ahmed
    Cordell, Rebecca
    Wilde, Michael
    Brightling, Christopher
    Monks, Paul
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [5] Proton-transfer reaction time-of-flight mass spectrometry.
    Bradshaw, JA
    Whetten, RL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U311 - U311
  • [6] A new method for real-time monitoring of volatiles in frying fumes using proton transfer reaction mass spectrometry with time-of-flight analyser
    Tomasz Majchrzak
    Wojciech Wojnowski
    Tomasz Dymerski
    Jacek Gębicki
    Jacek Namieśnik
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1549 - 1554
  • [7] A new method for real-time monitoring of volatiles in frying fumes using proton transfer reaction mass spectrometry with time-of-flight analyser
    Majchrzak, Tomasz
    Wojnowski, Wojciech
    Dymerski, Tomasz
    Gebicki, Jacek
    Namiesnik, Jacek
    MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1549 - 1554
  • [8] Proton Transfer Reaction Time. of. Flight Mass Spectrometry for Detection of Trace Volatile Organic Compounds in Breath
    Han Ming-Cong
    Dong Jun-Guo
    Peng, Zhen
    Xu Li
    Cheng Ping
    Zhou Zhen
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (07) : 1109 - 1115
  • [9] Real-time monitoring of respiratory absorption factors of volatile organic compounds in ambient air by proton transfer reaction time-of-flight mass spectrometry
    Huang, Zhonghui
    Zhang, Yanli
    Yan, Qiong
    Zhang, Zhou
    Wang, Xinming
    JOURNAL OF HAZARDOUS MATERIALS, 2016, 320 : 547 - 555
  • [10] In cleanroom, sub-ppb real-time monitoring of Volatile Organic Compounds using Proton-Transfer Reaction/Time of Flight/Mass Spectrometry
    Hayeck, Nathalie
    Maillot, Philippe
    Vitrani, Thomas
    Pic, Nicolas
    Wortham, Henri
    Gligorovski, Sasho
    Temime-Roussel, Brice
    Mizzi, Aurelie
    Poulet, Irene
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XXVIII, 2014, 9050