Evaluation of the Performance Characteristics of an In-House One Step TaqMan Real Time-Polymerase Chain Reaction Assay for Detection and Quantification of Hepatitis C Virus

被引:2
作者
Kermani, Fahimeh Ranjbar [1 ]
Kafi-Abad, Sedigheh Amini [1 ]
Hosseini, Kamran Mousavi [1 ]
Maghsoudlu, Mahtab [1 ]
Sharifi, Zohre [1 ]
Samiee, Shahram [1 ]
机构
[1] High Inst Res & Educ Transfus Med, Blood Transfus Res Ctr, Tehran, Iran
关键词
Hepatitis C Virus; Real Time RT-PCR; Probe; Quantification PCR; COBAS AMPLIPREP/COBAS TAQMAN; HCV; PCR; RNA; MANAGEMENT; DIAGNOSIS; PEGINTERFERON-ALPHA-2A; QUANTITATION; INFECTION; SIGNAL;
D O I
10.5812/jjm.42884
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: With theimprovementof quantitative molecular hepatitisCvirus (HCV) RNAassays, the usefulness of these assays has been indicated for management of HCV infection. Recently, various real time assays with different methodology and performance characteristics have been introduced. Objectives: This study aimed at designing, developing, and evaluating an in-house 1 step TaqMan real time-polymerase chain reaction (RT-PCR) assay for detection and quantification of HCV-RNA. Methods: The primers and probe were selected from a highly conserved region of the HCV genome, which allowed the detection of 4 common HCV genotypes in Iran. Using 4 quantification standards from 101 IU/mu L to 104 IU/mu L and clinical specimens, the current study determined analytical sensitivity, linear range, precision, analytical and clinical specificity, and validity of the assay. Data was analyzed by the SPSS statistical software (version 16). Results: The sensitivity of the assay with 95% probability, determined by probit analysis, was 15 IU/mu L. The assay showed a linear range of 101 IU/mu L to 104 IU/mu L (R-2 = 0.989). The coefficient of variation for intra and inter assay precision of the assay, based on threshold cycle value, ranged from 0.24 to 0.4, and from 1.94 to 3.19, respectively. The analytical and clinical specificity was 100%. No bias in relation to concentration between the results of 29 HCV RNA positive clinical specimens, simultaneously tested by artus HCV LC RT-PCR reagents and in-house reagents, was observed in the method comparison. Conclusions: The in-house 1 step TaqMan Real Time RT-PCR assay showed acceptable performance characteristics. Our study presents the robustness and cost-effectiveness of the method for detection and quantification of HCV RNA.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] SYBR green-based one step quantitative real-time polymerase chain reaction assay for the detection of Zika virus in field-caught mosquitoes
    Tien, Wei-Ping
    Lim, Gareth
    Yeo, Gladys
    Chiang, Suzanna Nicole
    Chong, Chee-Seng
    Ng, Lee-Ching
    Hapuarachchi, Hapuarachchige Chanditha
    PARASITES & VECTORS, 2017, 10
  • [32] In-house abbreviated qualification of a real-time polymerase chain reaction method and strategies to amplify mycoplasma detection in human mesenchymal stromal cells
    Mathews, Smitha
    Rabani, Razieh
    Rasti, Mozhgan
    Viswanathan, Sowmya
    CYTOTHERAPY, 2021, 23 (11) : 1036 - 1044
  • [33] Quantitative assessment of hepatitis C virus RNA by polymerase chain reaction and a digoxigenin detection system: Comparison with branched DNA assay
    Yeh, CT
    Shyu, WC
    Sheen, IS
    Chu, CM
    Liaw, YF
    JOURNAL OF VIROLOGICAL METHODS, 1997, 65 (02) : 219 - 226
  • [34] Single-step reverse transcription-polymerase chain reaction for the detection of hepatitis C virus RNA
    Mizutani, T
    Ikeda, M
    Saito, S
    Sugiyama, K
    Shimotohno, K
    Kato, N
    MICROBIOLOGY AND IMMUNOLOGY, 1998, 42 (08) : 549 - 553
  • [35] CLINICAL-EVALUATION OF A NEW POLYMERASE CHAIN-REACTION ASSAY (AMPLICOR(TM) HCV) FOR DETECTION OF HEPATITIS-C VIRUS
    ZEUZEM, S
    RUSTER, B
    ROTH, WK
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 1994, 32 (06): : 342 - 347
  • [36] DETECTION OF HEPATITIS-C VIRUS-RNA BY A RELIABLE, OPTIMIZED SINGLE-STEP REVERSE TRANSCRIPTION-POLYMERASE CHAIN-REACTION
    PAYAN, C
    DUPRE, T
    BELEC, L
    RESEARCH IN VIROLOGY, 1995, 146 (05): : 363 - 370
  • [37] TaqMan-based real-time polymerase chain reaction assay for specific detection of bocavirus-1 in domestic cats
    Wang, Yong
    Sun, Jianfei
    Guo, Xu
    Zhang, Da
    Cui, Yongqiu
    Li, Wei
    Liu, Guangqing
    Li, Yongdong
    Jiang, Shudong
    MOLECULAR AND CELLULAR PROBES, 2020, 53
  • [38] Two-step glutamate dehydrogenase antigen real-time polymerase chain reaction assay for detection of toxigenic Clostridium difficile
    Goldenberg, S. D.
    Cliff, P. R.
    Smith, S.
    Milner, M.
    French, G. L.
    JOURNAL OF HOSPITAL INFECTION, 2010, 74 (01) : 48 - 54
  • [39] Evaluation of real-time reverse transcription polymerase chain reaction assays for the detection of swine vesicular disease virus
    Reid, SM
    Ferris, NP
    Hutchings, GH
    King, DP
    Alexandersen, S
    JOURNAL OF VIROLOGICAL METHODS, 2004, 116 (02) : 169 - 176
  • [40] Short Report: Comprehensive Panel of Real-Time TaqMan™ Polymerase Chain Reaction Assays for Detection and Absolute Quantification of Filoviruses, Arenaviruses, and New World Hantaviruses
    Trombley, Adrienne R.
    Wachter, Leslie
    Garrison, Jeffrey
    Buckley-Beason, Valerie A.
    Jahrling, Jordan
    Hensley, Lisa E.
    Schoepp, Randal J.
    Norwood, David A.
    Goba, Augustine
    Fair, Joseph N.
    Kulesh, David A.