Evaluation of the Performance Characteristics of an In-House One Step TaqMan Real Time-Polymerase Chain Reaction Assay for Detection and Quantification of Hepatitis C Virus

被引:2
|
作者
Kermani, Fahimeh Ranjbar [1 ]
Kafi-Abad, Sedigheh Amini [1 ]
Hosseini, Kamran Mousavi [1 ]
Maghsoudlu, Mahtab [1 ]
Sharifi, Zohre [1 ]
Samiee, Shahram [1 ]
机构
[1] High Inst Res & Educ Transfus Med, Blood Transfus Res Ctr, Tehran, Iran
关键词
Hepatitis C Virus; Real Time RT-PCR; Probe; Quantification PCR; COBAS AMPLIPREP/COBAS TAQMAN; HCV; PCR; RNA; MANAGEMENT; DIAGNOSIS; PEGINTERFERON-ALPHA-2A; QUANTITATION; INFECTION; SIGNAL;
D O I
10.5812/jjm.42884
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: With theimprovementof quantitative molecular hepatitisCvirus (HCV) RNAassays, the usefulness of these assays has been indicated for management of HCV infection. Recently, various real time assays with different methodology and performance characteristics have been introduced. Objectives: This study aimed at designing, developing, and evaluating an in-house 1 step TaqMan real time-polymerase chain reaction (RT-PCR) assay for detection and quantification of HCV-RNA. Methods: The primers and probe were selected from a highly conserved region of the HCV genome, which allowed the detection of 4 common HCV genotypes in Iran. Using 4 quantification standards from 101 IU/mu L to 104 IU/mu L and clinical specimens, the current study determined analytical sensitivity, linear range, precision, analytical and clinical specificity, and validity of the assay. Data was analyzed by the SPSS statistical software (version 16). Results: The sensitivity of the assay with 95% probability, determined by probit analysis, was 15 IU/mu L. The assay showed a linear range of 101 IU/mu L to 104 IU/mu L (R-2 = 0.989). The coefficient of variation for intra and inter assay precision of the assay, based on threshold cycle value, ranged from 0.24 to 0.4, and from 1.94 to 3.19, respectively. The analytical and clinical specificity was 100%. No bias in relation to concentration between the results of 29 HCV RNA positive clinical specimens, simultaneously tested by artus HCV LC RT-PCR reagents and in-house reagents, was observed in the method comparison. Conclusions: The in-house 1 step TaqMan Real Time RT-PCR assay showed acceptable performance characteristics. Our study presents the robustness and cost-effectiveness of the method for detection and quantification of HCV RNA.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Development and validation of an efficient in-house real-time reverse transcription polymerase chain reaction assay for the quantitative detection of serum hepatitis delta virus RNA in a diverse South London population
    Shang, Dazhuang
    Hughes, Sarah A.
    Horner, Mary
    Bruce, Matthew J.
    Dong, Yan
    Carey, Ivana
    Suddle, Abid R.
    Agarwal, Kosh
    Harrison, Phillip M.
    Atkins, Mark
    JOURNAL OF VIROLOGICAL METHODS, 2012, 184 (1-2) : 55 - 62
  • [2] An in-house real-time polymerase chain reaction: standardisation and comparison with the Cobas Amplicor HBV monitor and Cobas AmpliPrep/Cobas TaqMan HBV tests for the quantification of hepatitis B virus DNA
    de Torres Santos, Ana Paula
    Levi, Jose Eduardo
    Lemos, Marcilio Figueiredo
    Calux, Samira Julien
    Oba, Isabel Takano
    Moreira, Regina Celia
    MEMORIAS DO INSTITUTO OSWALDO CRUZ, 2016, 111 (02): : 134 - 140
  • [3] Novel single-step multiplex real-time polymerase chain reaction assay for simultaneous quantification of hepatitis virus A, B, C, and E in serum
    Irshad, Mohammad
    Ansari, Mohammad Ahmad
    Irshad, Khushboo
    Lingaiah, Raghavendra
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 (12) : 1869 - 1876
  • [4] Development of a TaqMan Real-Time Polymerase Chain Reaction Assay for Detection of Burkholderia mallei
    Pal, Vijai
    Saxena, Apoorva
    Singh, Sandeep
    Kumar, Subodh
    Goel, Ajay Kumar
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2017, 58 : 58 - 63
  • [5] Quantitation of hepatitis C virus using an in-house real-time reverse transcriptase polymerase chain reaction in plasma samples
    Daniel, Hubert Darius J.
    Chandy, George M.
    Abraham, Priya
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2008, 61 (04) : 415 - 420
  • [6] A simple real-time polymerase chain reaction assay using SYBR Green for hepatitis C virus genotyping
    Zaghloul, Hosam
    El Morsi, A. A.
    Soweha, H. E.
    Elsayed, Ashraf
    Seif, S.
    El-Sharawy, Hossam
    ARCHIVES OF VIROLOGY, 2017, 162 (01) : 57 - 61
  • [7] Development of a TaqMan-based real-time reverse transcription polymerase chain reaction assay for the detection of encephalomyocarditis virus
    Yuan, Wanzhe
    Zheng, Yingshuai
    Sun, Mingtan
    Zhang, Xiuyuan
    Qi, Yan
    Sun, Jiguo
    JOURNAL OF VIROLOGICAL METHODS, 2014, 207 : 60 - 65
  • [8] Development of an In-House TaqMan Real Time RT-PCR Assay to Quantify Hepatitis C Virus RNA in Serum and Peripheral Blood Mononuclear Cells in Patients With Chronic Hepatitis C Virus Infection
    Fahlyani, Bahman Khalvati
    Behzad-Behbahani, Abbas
    Taghavi, Seiied Alireza
    Farhadi, Ali
    Salehi, Saeede
    Adibzadeh, Setare
    Aboualizadeh, Farzaneh
    Alavi, Parniyan
    Nikouyan, Negin
    Okhovat, Mohammad Ali
    Ranjbaran, Reza
    Dehbidi, Gholam Reza Rafiei
    Shakibzadeh, Arash
    HEPATITIS MONTHLY, 2015, 15 (08)
  • [9] Real-time reverse transcription polymerase chain reaction assay using TaqMan probe for detection and quantification of Infectious myonecrosis virus (INMV)
    Andrade, Thales P. D.
    Srisuvan, Thinnarat
    Tang, Kathy F. J.
    Lightner, Donald V.
    AQUACULTURE, 2007, 264 (1-4) : 9 - 15
  • [10] Utility of normalized genome quantification of Helicobacter pylori in gastric mucosa using an in-house real-time polymerase chain reaction
    Morilla, Ana
    Melon, Santiago
    Alvarez-Arguelles, Marta E.
    Armesto, Edisa
    Villar, Henar
    de Ona, Maria
    PLOS ONE, 2017, 12 (06):