Measurement of 2-D dose distributions by large-area thermolumine scent detectors

被引:19
作者
Marczewska, B
Bilski, P
Olko, P
Waligórski, MPR
机构
[1] Inst Nucl Phys, Hlth Phys Lab, PL-31342 Krakow, Poland
[2] Ctr Oncol, Krakow, Poland
关键词
thermoluminescent detectors; dose distribution; planar reader;
D O I
10.1016/j.radmeas.2004.03.014
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A novel method of determining two-dimensional (2-D) dose distributions was developed using in-house produced large-area thermoluminescent (TL) detectors based on LiF, read with a newly developed planar large-area TL reader equipped with a CCD camera. The detectors were developed by attaching, pressing and sintering thermoluminescent LiF:Mg,Ti or LiF:Mg,Cu,P powder on Al foil of 0.3 mm thickness. The detectors, of active area of a few square centimeters, read out using the large-area TL reader, were successfully used to map the 2-D dose distribution around an alpha source Am-241, a Ra-226 needle source and a Ru-106 ophthalmic applicator. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:833 / 837
页数:5
相关论文
共 9 条
[1]   Miniature thermoluminescent detectors for dosimetry in radiotherapy [J].
Bilski, P ;
Waligórski, MPR ;
Budzanowski, M ;
Ochab, E ;
Olko, P .
RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) :473-476
[2]   Use of BANG® polymer gel for dose measurements in a 68 MeV proton beam [J].
Heufelder, J ;
Stiefel, S ;
Pfaender, M ;
Lüdemann, L ;
Grebe, G ;
Heese, J .
MEDICAL PHYSICS, 2003, 30 (06) :1235-1240
[3]   CVD diamond wafers as large-area thermoluminescence detectors for measuring the spatial distribution of dose [J].
Marczewska, B ;
Bilski, P ;
Olko, P ;
Nesládek, M ;
Bergonzo, P ;
Rebisz, M ;
Waligórski, MPR .
PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 2003, 199 (01) :119-124
[4]  
Marczewska B, 2002, PHYS STATUS SOLIDI A, V193, P470, DOI 10.1002/1521-396X(200210)193:3<470::AID-PSSA470>3.0.CO
[5]  
2-P
[6]   Dosimetry characterization of a 32P source wire used for intravascular brachytherapy with automated stepping [J].
Mourtada, F ;
Soares, CG ;
Seltzer, SM ;
Bergstrom, PM ;
Fernández-Verea, JM ;
Asenjo, J ;
Lott, SH .
MEDICAL PHYSICS, 2003, 30 (05) :959-971
[7]   The use of radiographic firm for linear accelerator stereotactic radiosurgical dosimetry [J].
Robar, JL ;
Clark, BG .
MEDICAL PHYSICS, 1999, 26 (10) :2144-2150
[8]   Laser heating of thermoluminescent films: Dose mapping applied to beta dosimetry [J].
Setzkorn, R ;
Prevost, H ;
Gasiot, J ;
Christensen, P .
RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) :419-422
[9]   Characteristics of sensitometric curves of radiographic films [J].
Zhu, XR ;
Yoo, S ;
Jursinic, PA ;
Grimm, DF ;
Lopez, F ;
Rownd, JJ ;
Gillin, MT .
MEDICAL PHYSICS, 2003, 30 (05) :912-919