Performance of a picosecond x-ray delay line unit at 8.39 keV

被引:70
|
作者
Roseker, Wojciech [1 ]
Franz, Hermann [1 ]
Schulte-Schrepping, Horst [1 ]
Ehnes, Anita [1 ]
Leupold, Olaf [1 ]
Zontone, Federico [2 ]
Robert, Aymeric [3 ]
Gruebel, Gerhard [1 ]
机构
[1] DESY, Hamburger Synchrontronstschlungslab, D-22603 Hamburg, Germany
[2] European Synchrotron Radiat Facil, F-38043 Grenoble 09, France
[3] SLAC Natl Accelerator Lab, Menlo Pk, CA 94025 USA
关键词
SYNCHROTRON-RADIATION;
D O I
10.1364/OL.34.001768
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A prototype device capable of splitting an x-ray pulse into two adjustable fractions, delaying one of them with the aim to perform x-ray photon correlation spectroscopy and pump-probe type studies, was designed, manufactured, and tested. The device utilizes eight perfect silicon crystals in vertical 90 degrees scattering geometry. Its performance has been verified with 8.39 keV synchrotron radiation. The measured throughput of the device with a Si(333) premonachromator at 8.39 keV under ambient conditions is 0.6%. Time delays up to 2.62 ns have been achieved, detected with a time resolution of 16.7 ps. (C) 2009 Optical Society of America
引用
收藏
页码:1768 / 1770
页数:3
相关论文
共 50 条
  • [1] Single shot diffraction of picosecond 8.7-keV x-ray pulses
    O'Shea, F. H.
    Williams, O.
    Andonian, G.
    Barber, S.
    Sakai, Y.
    Rosenzweig, J. B.
    Pogorelsky, I.
    Fedurin, M.
    Kusche, K.
    Yakimenko, V.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2012, 15 (02):
  • [2] Magnetic dark matter for the X-ray line at 3.55 keV
    Lee, Hyun Min
    PHYSICS LETTERS B, 2014, 738 : 118 - 122
  • [3] Progresses of a Hard X-Ray Split and Delay Line Unit for the MID Station at the European XFEL
    Lu, W.
    Friedrich, B.
    Noll, T.
    Zhou, K.
    Hallmann, J.
    Ansaldi, G.
    Roth, T.
    Serkez, S.
    Geloni, G.
    Madsen, A.
    Eisebitt, S.
    X-RAY LASERS 2018, 2020, 241 : 131 - 137
  • [4] PICOSECOND X-RAY DIFFRACTION
    Wark, Justin
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 8 - 8
  • [5] PICOSECOND X-RAY CHRONOSCOPY
    BRADLEY, DJ
    RODDIE, AG
    SIBBETT, W
    KEY, MH
    LAMB, MJ
    LEWIS, CLS
    SACHSENMAIER, P
    OPTICS COMMUNICATIONS, 1975, 15 (02) : 231 - 236
  • [6] Picosecond X-ray Sensor
    Durbin, Stephen M.
    Mahmood, Aamer
    2012 IEEE SENSORS PROCEEDINGS, 2012, : 2216 - 2218
  • [7] PICOSECOND X-RAY PULSES
    OLSEN, JN
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1974, QE10 (09) : 780 - 780
  • [8] THE X-RAY LINE FEATURE AT 3.5 KeV IN GALAXY CLUSTER SPECTRA
    Phillips, K. J. H.
    Sylwester, B.
    Sylwester, J.
    ASTROPHYSICAL JOURNAL, 2015, 809 (01):
  • [9] PERFORMANCE OF AN X-RAY OPTICAL-TIME DELAY-LINE WITH SYNCHROTRON RADIATION
    JOKSCH, S
    GRAEFF, W
    HASTINGS, JB
    SIDDONS, DP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 1114 - 1118
  • [10] The 7 keV axion dark matter and the X-ray line signal
    Higaki, Tetsutaro
    Jeong, Kwang Sik
    Takahashi, Fuminobu
    PHYSICS LETTERS B, 2014, 733 : 25 - 31