Performance of a picosecond x-ray delay line unit at 8.39 keV

被引:70
作者
Roseker, Wojciech [1 ]
Franz, Hermann [1 ]
Schulte-Schrepping, Horst [1 ]
Ehnes, Anita [1 ]
Leupold, Olaf [1 ]
Zontone, Federico [2 ]
Robert, Aymeric [3 ]
Gruebel, Gerhard [1 ]
机构
[1] DESY, Hamburger Synchrontronstschlungslab, D-22603 Hamburg, Germany
[2] European Synchrotron Radiat Facil, F-38043 Grenoble 09, France
[3] SLAC Natl Accelerator Lab, Menlo Pk, CA 94025 USA
关键词
SYNCHROTRON-RADIATION;
D O I
10.1364/OL.34.001768
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A prototype device capable of splitting an x-ray pulse into two adjustable fractions, delaying one of them with the aim to perform x-ray photon correlation spectroscopy and pump-probe type studies, was designed, manufactured, and tested. The device utilizes eight perfect silicon crystals in vertical 90 degrees scattering geometry. Its performance has been verified with 8.39 keV synchrotron radiation. The measured throughput of the device with a Si(333) premonachromator at 8.39 keV under ambient conditions is 0.6%. Time delays up to 2.62 ns have been achieved, detected with a time resolution of 16.7 ps. (C) 2009 Optical Society of America
引用
收藏
页码:1768 / 1770
页数:3