The Oval-like Cross-section of Femoral Neck Isthmus in Three-dimensional Morphological Analysis

被引:8
|
作者
Zhang, Ru-yi [1 ,2 ]
Zhao, Yan-peng [3 ]
Su, Xiu-yun [4 ]
Li, Jian-tao [3 ]
Zhao, Jing-xin [2 ]
Zhang, Li-cheng [3 ]
Tang, Pei-fu [2 ,3 ]
机构
[1] Capital Med Univ, Dept Orthopaed, Shijingshan Teaching Hosp, Beijing, Peoples R China
[2] Med Sch Chinese PLA, Beijing, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Dept Orthopaed, Natl Clin Res Ctr Orthoped Sports Med & Rehabil, Beijing, Peoples R China
[4] Southern Univ Sci & Technol Hosp, Dept Orthopaed, Shenzhen, Peoples R China
关键词
3D; Area; Cross-section; Femoral neck isthmus; Oval-like; INTERNAL SCREW FIXATION; HIP-FRACTURES; ARTHROPLASTY; FEMUR; SIZE;
D O I
10.1111/os.12914
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To investigate the cross-section shape of the femoral neck isthmus (FNI) in three-dimensional reconstruction model of the femoral neck. Methods: From December 2009 to December 2012, computed tomography (CT) data of bilateral hip joint from 200 consecutive patients (137 males and 63 females, 69.41 +/- 9.21 years old, ranged from 50-85 years old) who underwent surgical treatments for proximal femoral fracture were retrospectively reviewed. The 3D model of the proximal femur was reconstructed, and the "inertia axis" method, which was applied to measure the long and short axes of the cross-section of the FNI, was established. The cross-sectional area and perimeter were calculated by a formula using the length of the long and short axes and then compared with the actual measured values by the software. Correlation between the descriptive parameters of the FNI cross-section (area, perimeter, and eccentricity) and patients' demographics (age, height, and weight) was analyzed. Stepwise linear regression analysis was used to determine the main relevant factors. Results: The ICC results showed excellent data reproducibility ranged from 0.989 to 0.996. There was no significant difference in the cross-sectional area of the FNI between the actual measured values and the predicted values using the formula (732.83 +/- 126.74 mm(2) vs 731.62 +/- 128.15 mm(2), P = 0.322). The perimeter using the two methods showed narrow while significant difference (97.86 +/- 8.60 mm vs 92.84 +/- 8.65 mm, P < 0.001), the actual measured values were about 5 mm greater than the predicted values. The parameters (area, perimeter, and eccentricity) were significantly larger in male than female (P < 0.001). A positive correlation between the cross-sectional area, perimeter, height, and weight was observed. The stepwise linear regression analysis showed that the regression equation of the FNI area was as follows: Y = -1083.75 + 1033.86 x HEIGHT + 1.92 x WEIGHT, R-2 = 0.489. Conclusion: The cross-section shape of the FNI appears to be oval-like in the 3D model, which is separated according to the inertia axis, and the findings proposed an anatomical basis for the further study of the spatial configuration of cannulated screws in the treatment of femoral neck fractures.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 50 条
  • [1] Three-dimensional morphological analysis of the femoral neck torsion angle—an anatomical study
    Ru-Yi Zhang
    Xiu-Yun Su
    Jing-Xin Zhao
    Jian-Tao Li
    Li-Cheng Zhang
    Pei-Fu Tang
    Journal of Orthopaedic Surgery and Research, 15
  • [2] Three-dimensional vibration analysis of prisms with isosceles triangular cross-section
    Zhou, Ding
    Cheung, Y. K.
    Lo, S. H.
    Au, F. T. K.
    ARCHIVE OF APPLIED MECHANICS, 2010, 80 (06) : 699 - 710
  • [3] Three-dimensional vibration analysis of prisms with isosceles triangular cross-section
    Ding Zhou
    Y. K. Cheung
    S. H. Lo
    F. T. K. Au
    Archive of Applied Mechanics, 2010, 80 : 699 - 710
  • [4] Three-dimensional morphological analysis of the femoral neck torsion angle-an anatomical study
    Zhang, Ru-Yi
    Su, Xiu-Yun
    Zhao, Jing-Xin
    Li, Jian-Tao
    Zhang, Li-Cheng
    Tang, Pei-Fu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [5] Three-Dimensional Analysis of the Characteristics of the Femoral Canal Isthmus: An Anatomical Study
    Su, Xiu-yun
    Zhao, Jing-xin
    Zhao, Zhe
    Zhang, Li-cheng
    Li, Chen
    Li, Jian-tao
    Zhou, Jian-feng
    Zhang, Li-hai
    Tang, Pei-fu
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [6] On the three-dimensional vibrations of elastic prisms with skew cross-section
    Zhou, D.
    McGee, O. G., III
    MECCANICA, 2013, 48 (04) : 993 - 1016
  • [7] Three-dimensional numerical investigations on rectangular cross-section ejector
    Arun, K. M.
    Tiwari, Shaligram
    Mani, A.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 122 : 257 - 265
  • [8] On the three-dimensional vibrations of elastic prisms with skew cross-section
    D. Zhou
    O. G. McGee
    Meccanica, 2013, 48 : 993 - 1016
  • [9] Transport model based on three-dimensional cross-section generation for TRIGA core analysis
    Kriangchaiporn, N.
    Ivanov, K.
    Haghighat, A.
    Sears, C. F.
    ANNALS OF NUCLEAR ENERGY, 2010, 37 (09) : 1254 - 1260
  • [10] Three-dimensional vibration analysis of thick, tapered rods and beams with circular cross-section
    Kang, JH
    Leissa, AW
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2004, 46 (06) : 929 - 944