Ultrasound-assisted emulsification microextraction followed by gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry for the analysis of UV filters in water

被引:42
|
作者
Vila, Marlene [1 ]
Pablo Lamas, J. [1 ]
Garcia-Jares, Carmen [1 ]
Dagnac, Thierry [2 ]
Llompart, Maria [1 ]
机构
[1] Univ Santiago de Compostela, Dept Analyt Chem Nutr & Food Sci, Fac Chem, E-15782 Santiago De Compostela, Spain
[2] Agr & Agron Res Ctr INGACAL CIAM, Unit Organ Contaminants, La Coruna 15080, Spain
关键词
Ultrasound-assisted emulsification microextraction; GC-MS/MS; Personal care products (PCPs); Emerging pollutants; Water samples; UV-filters; LIQUID-LIQUID MICROEXTRACTION; BAR SORPTIVE EXTRACTION; PERSONAL CARE PRODUCTS; ULTRAVIOLET FILTERS; IONIC LIQUID; 4-METHYLBENZYLIDENE CAMPHOR; MULTICLASS DETERMINATION; SENSITIVE DETERMINATION; PHASE MICROEXTRACTION; SAMPLES;
D O I
10.1016/j.microc.2015.09.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A methodology based on ultrasound-assisted emulsification microextraction (USAEME) has been developed for the simultaneous analysis of ten UV filters (2-ethylhexyl methoxycinnamate (2EHMC), 4- methylbencylidene camphor (4MBC), benzyl salicylate (BS), ethylhexyl dimethyl PABA (EHPABA), ethylhexyl salicylate (EHS), etocrylene (Eto), homosalate (HMS), isoamyl methoxycinnamate (IAMC), menthyl anthranilate (MA) and octocrylene (OCR)) in different water samples employing two detection modes, gas chromatography-mass spectrometry (GC-MS), and gas chromatography-tandem mass spectrometry (GC-MS/MS). The extraction parameters such as the extraction solvent, the temperature and the time of extraction, and the addition of salt were optimized by means of experimental design tools. Selected conditions were 100 mu L of chloroform, 10 mL of sample, 2 g of salt (NaCl) and 5 min of extraction. Good linearity (R-2>0.9910), quantitative recoveries (>90% for most of compounds) and satisfactory precision (RSD < 10% in most cases) were achieved under the optimal conditions. The methodology was successfully applied to the analysis of different types of water samples including seawater, spas, rivers, swimming pools, and aquaparks, in which most of the target compounds were found at concentrations sometimes over the part per million. Since no significant matrix effect has been found for any of the water types analyzed, quantification could be carried out by using conventional external calibration, thereby allowing a high analytical throughput and a valuable protocol simplification. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:530 / 539
页数:10
相关论文
共 50 条
  • [41] Simultaneous in-vial acetylation solid-phase microextraction followed by gas chromatography tandem mass spectrometry for the analysis of multiclass organic UV filters in water
    Vila, Marlene
    Celeiro, Maria
    Pablo Lamas, J.
    Garcia-Jares, Carmen
    Dagnac, Thierry
    Llompart, Maria
    JOURNAL OF HAZARDOUS MATERIALS, 2017, 323 : 45 - 55
  • [42] Tandem pyrolysis evolved gas-gas chromatography-mass spectrometry☆
    Dwyer, Derek B.
    Niedziela, J. L.
    Miskowiec, Andrew
    JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 2025, 186
  • [43] Ultrasound-Assisted Extraction, Followed by Gas Chromatography-Mass Spectrometry for the Simultaneous Quantification of Ethinyl Estradiol and Drospirenone in Contraceptive Formulations
    Pena, Javier
    Gonzalez-Marino, Iria
    Pavon, Jose L. Perez
    MOLECULES, 2023, 28 (13):
  • [44] Determination of ultraviolet filters in water samples by vortex-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry
    Zhang, Yufeng
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1249 : 25 - 31
  • [45] Analysis of acetamiprid in vegetables using gas chromatography-tandem mass spectrometry
    Mateu-Sánchez, M
    Moreno, M
    Arrebola, FJ
    Vidal, JLM
    ANALYTICAL SCIENCES, 2003, 19 (05) : 701 - 704
  • [46] Simultaneous determination of PCBs, OCPs and PAHs in mussel by ultrasound-assisted cloudy extraction and gas chromatography-tandem mass spectrometry
    Lee, Jangho
    Lee, Soo Yong
    Park, Ki-Wan
    Lim, Hyun-Hee
    Shin, Ho-Sang
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2020, 37 (10): : 1730 - 1743
  • [47] Immersed solvent microextraction of phenol and chlorophenols from water samples followed by gas chromatography-mass spectrometry
    Bagheri, H
    Saber, A
    Mousavi, SR
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1046 (1-2) : 27 - 33
  • [48] Urinary screening for methylphenidate (Ritalin) abuse: a comparison of liquid chromatography-tandem mass spectrometry, gas chromatography-mass spectrometry, and immunoassay methods
    Eichhorst, J
    Etter, M
    Lepage, J
    Lehotay, DC
    CLINICAL BIOCHEMISTRY, 2004, 37 (03) : 175 - 183
  • [49] Comparison of gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry methods to quantify α-tocopherol and α-tocopherolquinone levels in human plasma
    Mottier, P
    Gremaud, E
    Guy, PA
    Turesky, RJ
    ANALYTICAL BIOCHEMISTRY, 2002, 301 (01) : 128 - 135
  • [50] Enantiomeric analysis of polycyclic musks in water by chiral gas chromatography-tandem mass spectrometry
    Wang, Lili
    McDonald, James A.
    Khan, Stuart J.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1303 : 66 - 75