A biomechanical analysis of meniscal repair techniques

被引:71
作者
Rankin, CC [1 ]
Lintner, DM [1 ]
Noble, PC [1 ]
Paraciv, V [1 ]
Greer, E [1 ]
机构
[1] Baylor Coll Med, Barnhart Dept Orthoped Surg, Baylor Sports Med Inst, Houston, TX 77030 USA
关键词
D O I
10.1177/03635465020300040801
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Various methods are available for repair of meniscal tears: a biodegradable meniscal implant without sutures (Biofix meniscus arrow), a suture anchor device (T-fix), and horizontal and vertical mattress sutures. Hypothesis: There is no difference in repair strength or mode of failure among the techniques compared. Study Design: Controlled laboratory study. Methods: Reproducible tears were created in bovine menisci and repaired with each of the techniques. Residual displacement of the tear immediately after repair and the resistance to displacement under load applied perpendicular to the tear were measured and compared. Results: The residual displacement;after repair was highest in the Biofix arrow group (0.70 mm) and lowest in the vertical mattress suture group (0.21 mm). The ultimate strength of repair was strongest for the vertical sutures (202 +/- 7 N) and lowest for the arrow and T-fix (95.9 +/- 8 N and 99.4 +/- 8 N, respectively). The force required to generate 2 mm of tear displacement was greatest for the vertical sutures (143 N) and least for the arrow (43.6 N). Conclusions: Suture techniques were stronger at all levels of testing. Clinical Relevance: Knowledge of biomechanical characteristics aids the surgeon in choosing the appropriate technique for each situation. (C) 2002 American Orthopaedic Society for Sports Medicine.
引用
收藏
页码:492 / 497
页数:6
相关论文
共 28 条
[1]  
Albrecht-Olsen P, 1993, Knee Surg Sports Traumatol Arthrosc, V1, P104, DOI 10.1007/BF01565462
[2]   Failure strength of a new meniscus arrow repair technique: Biomechanical comparison with horizontal suture [J].
AlbrechtOlsen, P ;
Lind, T ;
Kristensen, G ;
Falkenberg, B .
ARTHROSCOPY, 1997, 13 (02) :183-187
[3]   LATE DEGENERATIVE CHANGES AFTER MENISCECTOMY - FACTORS AFFECTING THE KNEE AFTER OPERATION [J].
ALLEN, PR ;
DENHAM, RA ;
SWAN, AV .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (05) :666-671
[4]   Meniscal repair devices [J].
Barber, FA ;
Herbert, MA .
ARTHROSCOPY, 2000, 16 (06) :613-618
[5]  
Barraviera B., 1995, Journal of Venomous Animals and Toxins, V1, P11
[6]   Pull-out strength and stiffness of meniscal repair using absorbable arrows or Ti-Cron vertical and horizontal loop sutures [J].
Boenisch, UW ;
Faber, KJ ;
Ciarelli, M ;
Steadman, JR ;
Arnoczky, SP .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (05) :626-631
[7]   ARTHROSCOPIC EVALUATION OF MENISCAL REPAIRS AFTER ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION AND IMMEDIATE MOTION [J].
BUSECK, MS ;
NOYES, FR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1991, 19 (05) :489-494
[8]  
DEHAVEN KE, 1990, CLIN SPORT MED, V9, P577
[9]   Failure strengths of suture versus biodegradable arrow for meniscal repair: An in vitro study [J].
Dervin, GF ;
Downing, KJW ;
Keene, GCR ;
McBride, DG .
ARTHROSCOPY, 1997, 13 (03) :296-300
[10]  
ELLERMANN A, 1999, ARTHROSCOPY, V15, pS24