Fixation of medial malleolar fractures with magnesium bioabsorbable headless compression screws: short-term clinical and radiological outcomes in eleven patients

被引:64
作者
Kose, Ozkan [1 ]
Turan, Adil [1 ]
Unal, Melih [1 ]
Acar, Baver [1 ]
Guler, Ferhat [1 ]
机构
[1] Univ Hlth Sci, Antalya Training & Res Hosp, Antalya Egitim & Arastirma Hastanesi, Dept Orthoped & Traumatol, TR-07100 Antalya, Turkey
关键词
Biodegradable implants; Magnesium screws; Ankle fractures; Functional outcome; Bioabsorbable implants; INTERNAL-FIXATION; IMPLANTS; SURGERY; REMOVAL;
D O I
10.1007/s00402-018-2941-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this retrospective study was to evaluate the outcome of medial malleolar fractures treated with magnesium (MgYREZr) bioabsorbable compression screw fixation. Eleven patients with a medial malleolar fracture (either isolated or accompanied by bimalleolar or trimalleolar ankle fractures) who were treated with magnesium bioabsorbable compression screws between 2015 and 2016 in our hospital were retrospectively evaluated. Patients were monitored with a mean follow-up of 17.3 +/- 4.1 months (range 12-24 months). The mechanism of injury was ground level falls in all patients. All fractures were classified as closed fractures. American Orthopedic Foot and Ankle Society's (AOFAS) scale and the visual analog scale (VAS) were used to evaluate the clinical results during the final follow-up. Bone union and a possible loss of reduction were assessed with serial radiographs. Potential complications including revision surgery and infection were recorded and reported. There were 11 patients (4 female, 7 male) with a mean age of 41 +/- 21.9 years (range 20-78 years). Six patients had Herscovici type C and five patients had type B fractures. At the final follow-up the mean AOFAS score was 94.9 +/- 5.7 points (range 85-100 points) and the mean VAS score was 0.4 +/- 1.2 points (range 0-4 points). Radiographic solid union was achieved in all cases. No complications were seen during the follow-up. No patients required implant removal or revision surgery. This is the first study that investigates the use of bioabsorbable magnesium compression screws in medial malleolar fractures. The results of this study revealed that fixation of medial malleolar fractures with bioabsorbable magnesium compression screws provides adequate fixation with good functional results. Level IV, therapeutic, retrospective case series.
引用
收藏
页码:1069 / 1075
页数:7
相关论文
共 25 条
[1]  
[Anonymous], 1991, MANUAL INTERNAL FIXA
[2]   A clinical evaluation of alternative fixation techniques for medial malleolus fractures [J].
Barnes, Hayley ;
Cannada, Lisa K. ;
Watson, J. Tracy .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (09) :1365-1367
[3]  
Biber R., 2016, CASE REP ORTHOP, V2016, DOI 10.1155/2016/9673174
[4]  
Biber Roland, 2017, Trauma Case Rep, V8, P11, DOI 10.1016/j.tcr.2017.01.012
[5]   Routine implant removal after fracture surgery: A potentially reducible consumer of hospital resources in trauma units [J].
Bostman, O ;
Pihlajamaki, H .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 41 (05) :846-849
[6]  
Bostman OM, 1996, CLIN ORTHOP RELAT R, P233
[7]   Incidence of hardware-related pain and its effect on functional outcomes after open reduction and internal fixation of ankle fractures [J].
Brown, OL ;
Dirschl, DR ;
Obremskey, WT .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (04) :271-274
[8]  
Collinge C, 2016, SURG TREATMENT ORTHO, P1018
[9]   Epidemiology of adult fractures: A review [J].
Court-Brown, Charles M. ;
Caesar, Ben .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (08) :691-697
[10]   The functional outcome and quality of life after treatment of isolated medial malleolar fractures [J].
Hanhisuanto, Sini ;
Kortekangas, Tero ;
Pakarinen, Harri ;
Flinkkila, Tapio ;
Leskela, Hannu-Ville .
FOOT AND ANKLE SURGERY, 2017, 23 (04) :225-229