Fast Current-Only Based Fault Detection Method in Transmission Line

被引:43
作者
Jarrahi, Mohammad Amin [1 ]
Samet, Haidar [1 ]
Ghanbari, Teymoor [2 ]
机构
[1] Shiraz Univ, Sch Elect & Comp Engn, Shiraz 7134851154, Iran
[2] Shiraz Univ, Sch Adv Technol, Shiraz 7194684636, Iran
来源
IEEE SYSTEMS JOURNAL | 2019年 / 13卷 / 02期
关键词
Distance relay; fault detection; moving average; transmission line (TL); CLASSIFICATION; PROTECTION; IDENTIFICATION; DIAGNOSIS; SCHEME;
D O I
10.1109/JSYST.2018.2822549
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
When a fault occurs in transmission lines, first, it is detected, then classified, and finally, located by a distance protection. Having a fast fault detection approach helps saving the required time for the whole protection procedure. In this paper, a novel method for fault detection of transmission lines based on the summation of squared three-phase currents (SSC) and a moving average technique is proposed. The SSC is constant during a normal condition of the network, while it has considerable variation under a fault condition. Using a moving average concept, a criterion is defined, by which fault occurrence can be detected. The proposed fault detection method is evaluated in four different systems: a typical 5-bus system, a typical double-circuit transmission line, WSCC 9-bus system, and a laboratory small-scaled system. The results confirm a high degree of accuracy and speed of the proposed approach. Moreover, the performance of the method is compared with some other similar methods from different aspects.
引用
收藏
页码:1725 / 1736
页数:12
相关论文
共 41 条
[1]   Fault Detection and Classification Based on Co-training of Semisupervised Machine Learning [J].
Abdelgayed, Tamer S. ;
Morsi, Walid G. ;
Sidhu, Tarlochan S. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (02) :1595-1605
[2]   A novel single end measuring system based fast identification scheme for transmission line faults [J].
Adly, Ahmed R. ;
El Sehiemy, Ragab A. ;
Abdelaziz, Almoataz Y. .
MEASUREMENT, 2017, 103 :263-274
[3]   Transmission lines differential protection based on an alternative incremental complex power alpha plane [J].
Almeida, Maria Leonor S. ;
Silva, Kleber M. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (01) :10-17
[4]  
[Anonymous], 2008, POWER SYSTEM RELAYIN
[5]  
[Anonymous], 2011, NUMERICAL DISTANCE P
[6]  
[Anonymous], 2009, COMPUTER RELAYING PO
[7]  
Baghace HR, 2008, PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, VOL I, P209
[8]   Fault detection, classification and location for transmission lines and distribution systems: a review on the methods [J].
Chen, Kunjin ;
Huang, Caowei ;
He, Jinliang .
HIGH VOLTAGE, 2016, 1 (01) :25-33
[9]   Two-Terminal Traveling-Wave-Based Transmission-Line Protection [J].
Costa, F. B. ;
Monti, A. ;
Lopes, F. V. ;
Silva, K. M. ;
Jamborsalamati, P. ;
Sadu, A. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (03) :1382-1393
[10]   Distance protection of shunt compensated transmission line using a sparse S-transform [J].
Dash, Pradipta Kishore ;
Das, Sahasransu ;
Moirangthem, Joymala .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (12) :1264-1274