Changes in ocular aberrations after instillation of artificial tears in dry-eye patients

被引:73
作者
Montés-Micó, R
Cáliz, A
Alió, JL
机构
[1] Univ Miguel Hernandez, Inst Oftalmol Alicante, Res Dev & Innovat Dept, Alicante 03015, Spain
[2] Univ Miguel Hernandez, Sch Med, Alicante 03015, Spain
关键词
D O I
10.1016/j.jcrs.2004.02.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To study the effect of artificial tear instillation on ocular aberrations in dry-eye patients. Setting. Research, Development and Innovation Department, Instituto Oftalmologico de Alicante, Alicante, Spain. Methods. Ocular aberrations (total, spherical-like, and coma-like) were measured with a Hartmann-Shack aberrometer before and after artificial tear instillation (immediately and 10 minutes later) in 15 eyes of 15 dry-eye patients. Results. Optical aberrations showed a statistically significant reduction after artificial tear instillation (P<.01). Total aberrations decreased on average by a factor of 2 to 3 times immediately after instillation; the reduction was maintained after 10 minutes (P>.01). Conclusions: After artificial tear instillation, the reduction in optical aberrations associated with an increasingly irregular tear film may cause an improvement in the optical quality of dry eyes. Wavefront analysis facilitates the evaluation of improvement in optical quality after artificial tear instillation in patients with dry eye. (C) 2004 ASCRS and ESCRS.
引用
收藏
页码:1649 / 1652
页数:4
相关论文
共 7 条
  • [1] Albarran C, 1997, Cont Lens Anterior Eye, V20, P129, DOI 10.1016/S1367-0484(97)80011-2
  • [2] Effect of artificial tears on corneal surface regularity, contrast sensitivity, and glare disability in dry eyes
    Huang, FC
    Tseng, SH
    Shih, MH
    Chen, FK
    [J]. OPHTHALMOLOGY, 2002, 109 (10) : 1934 - 1940
  • [3] Effect of tear film break-up on higher-order aberrations measured with wavefront sensor
    Koh, S
    Maeda, N
    Kuroda, T
    Hori, Y
    Watanabe, H
    Fujikado, T
    Tano, Y
    Hirohara, Y
    Mihashi, T
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (01) : 115 - 117
  • [4] Postblink changes in total and corneal ocular aberrations
    Montés-Micó, R
    Alió, JL
    Muñoz, G
    Pérez-Santonja, JJ
    Charman, WN
    [J]. OPHTHALMOLOGY, 2004, 111 (04) : 758 - 767
  • [5] Characterization of the visual performance with soft daily wear disposable contact lenses
    Pons, AM
    Lorente, A
    Albarran, C
    Montes, R
    Artigas, JM
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1998, 18 (01) : 40 - 48
  • [6] Clinical applications of the Shack-Hartmann aberrometer
    Thibos, LN
    Hong, X
    [J]. OPTOMETRY AND VISION SCIENCE, 1999, 76 (12) : 817 - 825
  • [7] Tutt R, 2000, INVEST OPHTH VIS SCI, V41, P4117