Specific compliance and gas exchange during high-frequency oscillatory ventilation

被引:5
作者
Wood, B
Karna, P
Adams, A
机构
[1] Sparrow Hosp, Lansing, MI 48909 USA
[2] Mission St Josephs Med Ctr, Asheville, NC USA
[3] Kings Daughters Childrens Hosp, Norfolk, VA USA
关键词
high-frequency oscillatory ventilation; functional residual capacity; compliance; surfactant deficient;
D O I
10.1097/00003246-200207000-00021
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To evaluate the use of specific compliance (static compliance/functional residual capacity) to adjust mean airway pressure, resulting in optimal gas exchange during high-frequency oscillatory ventilation in a surfactant-deficient newborn piglet. Design: Prospective controlled animal study. Setting: Laboratory. Subjects: Eight newborn piglets at 5 days of age. Background: High-frequency oscillatory ventilation enables the use of relatively high mean airway pressures without the lung damage associated with conventional positive pressure ventilation. Mean airway pressures can be increased, resulting in static lung expansion that approaches total lung capacity with its negative impact on venous return. Therefore, knowledge of lung volume is important for safe patient management. A simple, noninvasive technique to enable the clinician to determine the optimal mean airway pressure likely would improve patient management. Interventions: The lungs were lavaged after placement of central catheters and tracheostomy to lower respiratory system compliance and worsen ventilation perfusion matching. The animals were ventilated with high-frequency oscillatory ventilation at the same mean airway pressure as before lung lavage. Mean airway pressures then were increased in a step-wise fashion up to 30 cm H(2)0 or until clinical deterioration occurred. All other ventilator variables, F10(2), frequency, and pressure amplitude were constant throughout the experiment. Measurements and Main Results: Before lavage and at each level of mean airway pressure after lung lavage, respiratory system compliance and functional residual capacity were measured. Additionally, central arterial pressure, central venous pressure, heart rate, arterial blood gas, and pulse oximetric saturation were recorded. Lung lavage significantly lowered respiratory system compliance (static as well as specific compliance) and worsened ventilation perfusion matching as evidenced by an increase in Pac0(2) and a decreased arterial to alveolar oxygen ratio. With increasing mean airway pressures, static/specific compliance improved and then peaked before declining, functional residual capacity increased, and blood gas improved until reaching the flat portion of the pressure-volume relationship of the lung. Optimal gas exchange as reflected by the highest arterial to alveolar oxygen ratio and lowest Pac0(2) at constant ventilation was found at a mean airway pressure that maintained the functional residual capacity and static respiratory system compliance at the same level as the preinjury levels ("normalized" functional residual capacity and respiratory system compliance). Conclusions., These results suggest that specific compliance measurement that incorporates static respiratory system compliance and functional residual capacity during high-frequency oscillatory ventilation can be used to adjust mean airway pressure and achieve "normalized" functional residual capacity, static compliance, and gas exchange. These measurements may provide a simple method to optimize lung volume in a surfactant-deficient patient during high-frequency oscillatory ventilation.
引用
收藏
页码:1523 / 1527
页数:5
相关论文
共 32 条
[1]  
BALSAN MJ, 1993, AM REV RESPIR DIS, V147, pA422
[2]  
BAR-YISHAY E, 1991, American Review of Respiratory Disease, V143, pA129
[3]   RAPID IMPROVEMENT OF STATIC COMPLIANCE AFTER SURFACTANT TREATMENT IN PRETERM INFANTS WITH RESPIRATORY-DISTRESS SYNDROME [J].
BARALDI, E ;
PETTENAZZO, A ;
FILIPPONE, M ;
MAGAGNIN, GP ;
SAIA, OS ;
ZACCHELLO, F .
PEDIATRIC PULMONOLOGY, 1993, 15 (03) :157-162
[4]   VOLUME RECRUITMENT MANEUVERS ARE LESS DELETERIOUS THAN PERSISTENT LOW LUNG-VOLUMES IN THE ATELECTASIS-PRONE RABBIT LUNG DURING HIGH-FREQUENCY OSCILLATION [J].
BOND, DM ;
FROESE, AB .
CRITICAL CARE MEDICINE, 1993, 21 (03) :402-412
[5]   REFLEX CARDIOVASCULAR DEPRESSION DURING UNILATERAL LUNG HYPER-INFLATION IN THE DOG [J].
CASSIDY, SS ;
ESCHENBACHER, WL ;
JOHNSON, RL .
JOURNAL OF CLINICAL INVESTIGATION, 1979, 64 (02) :620-626
[6]   Ventilator-induced lung injury - Lessons from experimental studies [J].
Dreyfuss, D ;
Saumon, G .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (01) :294-323
[7]   LUNG-INFLATION, LUNG SOLUTE PERMEABILITY, AND ALVEOLAR EDEMA [J].
EGAN, EA .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (01) :121-125
[8]   A SIMPLE METHOD FOR MEASURING FUNCTIONAL RESIDUAL CAPACITY BY N-2 WASHOUT IN SMALL ANIMALS AND NEWBORN-INFANTS [J].
GERHARDT, T ;
HEHRE, D ;
BANCALARI, E ;
WATSON, H .
PEDIATRIC RESEARCH, 1985, 19 (11) :1165-1169
[9]   PROXIMAL, TRACHEAL, AND ALVEOLAR PRESSURES DURING HIGH-FREQUENCY OSCILLATORY VENTILATION IN A NORMAL RABBIT MODEL [J].
GERSTMANN, DR ;
FOUKE, JM ;
WINTER, DC ;
TAYLOR, AF ;
DELEMOS, RA .
PEDIATRIC RESEARCH, 1990, 28 (04) :367-374
[10]  
HIFI Study Group, 1989, N Engl J Med, V320, P88