Glucose Sensing in the Peritoneal Space Offers Faster Kinetics Than Sensing in the Subcutaneous Space

被引:41
作者
Burnett, Daniel R. [1 ]
Huyett, Lauren M. [2 ]
Zisser, Howard C. [2 ,3 ]
Doyle, Francis J., III [2 ]
Mensh, Brett D. [1 ,4 ]
机构
[1] Theranova LLC, San Francisco, CA 94107 USA
[2] Univ Calif Santa Barbara, Dept Chem Engn, Santa Barbara, CA 93106 USA
[3] Sansum Diabet Res Inst, Santa Barbara, CA USA
[4] Howard Hughes Med Inst, Ashburn, VA USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
CARBON-DIOXIDE TENSIONS; NOCTURNAL HYPOGLYCEMIA; ADIPOSE-TISSUE; MICRODIALYSIS; BLOOD; OXYGEN;
D O I
10.2337/db13-1649
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The paramount goal in the treatment of type 1 diabetes is the maintenance of normoglycemia. Continuous glucose monitoring (CGM) technologies enable frequent sensing of glucose to inform exogenous insulin delivery timing and dosages. The most commonly available CGMs are limited by the physiology of the subcutaneous space in which they reside. The very same advantages of this minimally invasive approach are disadvantages with respect to speed. Because subcutaneous blood flow is sensitive to local fluctuations (e. g., temperature, mechanical pressure), subcutaneous sensing can be slow and variable. We propose the use of a more central, physiologically stable body space for CGM: the intraperitoneal space. We compared the temporal response characteristics of simultaneously placed subcutaneous and intraperitoneal sensors during intravenous glucose tolerance tests in eight swine. Using compartmental modeling based on simultaneous intravenous sensing, blood draws, and intraarterial sensing, we found that intraperitoneal kinetics were more than twice as fast as subcutaneous kinetics (mean time constant of 5.6 min for intraperitoneal vs. 12.4 min for subcutaneous). Combined with the known faster kinetics of intraperitoneal insulin delivery over subcutaneous delivery, our findings suggest that artificial pancreas technologies may be optimized by sensing glucose and delivering insulin in the intraperitoneal space.
引用
收藏
页码:2498 / 2505
页数:8
相关论文
共 46 条
[21]   Surgical aspects and complications of continuous intraperitoneal insulin infusion with an implantable pump [J].
Haveman, Jan Willem ;
Logtenberg, Susan J. J. ;
Kleefstra, Nanne ;
Groenier, Klaas H. ;
Bilo, Henk J. G. ;
Blomme, Adri M. .
LANGENBECKS ARCHIVES OF SURGERY, 2010, 395 (01) :65-71
[22]  
Helton Kristen L, 2011, J Diabetes Sci Technol, V5, P647
[23]   Effects of glucose and insulin levels on adipose tissue glucose measurement by microdialysis probes retained for three weeks in Type 1 diabetic patients [J].
Hullegie, LM ;
Lutgers, HL ;
Dullaart, RPF ;
Sluiter, WJ ;
Wientjes, KJ ;
Schoonen, AJM ;
Hoogenberg, K .
NETHERLANDS JOURNAL OF MEDICINE, 2000, 57 (01) :13-19
[24]   Decreased epinephrine responses to hypoglycemia during sleep [J].
Jones, TW ;
Porter, P ;
Sherwin, RS ;
Davis, EA ;
O'Leary, P ;
Frazer, F ;
Byrne, G ;
Stick, S ;
Tamborlane, WV .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (23) :1657-1662
[25]   Subcutaneous a continuous glucose monitoring - Feasibility of a new microdialysis-based glucose sensor system [J].
Jungheim, K ;
Wientjes, KJ ;
Heinemann, L ;
Lodwig, V ;
Koschinsky, T ;
Koschinsky, T ;
Schoonen, AJ .
DIABETES CARE, 2001, 24 (09) :1696-1697
[26]  
Keenan D Barry, 2009, J Diabetes Sci Technol, V3, P1207
[27]  
King Christopher, 2007, J Diabetes Sci Technol, V1, P317
[28]   OXYGEN AND CARBON-DIOXIDE TENSIONS IN ABDOMINAL-CAVITY AND COLONIC WALL OF RABBIT [J].
KLOSSNER, J ;
KIVISAARI, J ;
NIINIKOSKI, J .
AMERICAN JOURNAL OF SURGERY, 1974, 127 (06) :711-715
[29]   Microdialysis measurement of glucose in subcutaneous adipose tissue up to three weeks in Type 1 diabetic patients [J].
Lutgers, HL ;
Hullegie, LM ;
Hoogenberg, K ;
Sluiter, WJ ;
Dullaart, RPF ;
Wientjes, KJ ;
Schoonen, AJM .
NETHERLANDS JOURNAL OF MEDICINE, 2000, 57 (01) :7-12
[30]   Spurious reporting of nocturnal hypoglycemia by CGMS in patients with tightly controlled type I diabetes [J].
McGowan, K ;
Thomas, W ;
Moran, A .
DIABETES CARE, 2002, 25 (09) :1499-1503