Biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures

被引:74
|
作者
Norton, Robert P. [1 ]
Milne, Edward L. [2 ]
Kaimrajh, David N. [2 ]
Eismont, Frank J. [1 ]
Latta, Loren L. [1 ,2 ]
Williams, Seth K. [3 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Orthopaed Surg, Miami, FL 33101 USA
[2] Mt Sinai Med Ctr, Max Biedermann Inst Biomech, Dept Res, Miami Beach, FL 33140 USA
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Orthopaed & Rehabil, Madison, WI 53705 USA
来源
SPINE JOURNAL | 2014年 / 14卷 / 08期
关键词
Short-segment fusion; Axial load fracture; Pedicle screw instrumentation; Spine fracture biomechanics; Spine fracture fixation; Thoracolumbar instrumentation; BURST FRACTURES; POSTERIOR INSTRUMENTATION; SPINE FRACTURES; IN-VIVO; INTERNAL-FIXATION; LUMBAR FUSION; LONG; ADJACENT; ANTERIOR; MODEL;
D O I
10.1016/j.spinee.2014.01.035
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Conventionally, short-segment fusion involves instrumentation of one healthy vertebra above and below the injured vertebra, skipping the injured level. This short-segment construct places less surgical burden on the patient compared with long-segment constructs, but is less stable biomechanically, and thus has resulted in clinical failures. The addition of two screws placed in the fractured vertebral body represents an attempt to improve the construct stiffness without sacrificing the benefits of short-segment fusion. PURPOSE: To determine the biomechanical differences between four-and six-screw short-segment constructs for the operative management of an unstable L1 fracture. STUDY DESIGN: Biomechanical study of instrumentation in vertebral body cadaveric models simulating an L1 axial load injury pattern. METHODS: Thirteen intact spinal segments from T12 to L2 were prepared from fresh-frozen cadaver spines. An axial load fracture of at least 50% vertebral body height was produced at L1 and then instrumented with pedicle screws. Specimens were evaluated in terms of construct stiffness, motion, and rod strain. Two conditions were tested: a four-screw construct with no screws at the L1 fractured body (4S) and a six-screw construct with screws at all levels (6S). The two groups were compared statistically by paired Student t test. RESULTS: The mean stiffness in flexion-extension was increased 31% (p < .03) with the addition of the two pedicle screws in L1. Relative motion in terms of vertical and axial rotations was not significantly different between the two groups. The L1-L2 rod strain was significantly increased in the six-screw construct compared with the four-screw construct (p < .001). CONCLUSIONS: In a cadaveric L1 axial load fracture model, a six-screw construct with screws in the fractured level is more rigid than a four-screw construct that skips the injured vertebral body. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1734 / 1739
页数:6
相关论文
共 50 条
  • [41] The role of fusion in the management of burst fractures of the thoracolumbar spine treated by short segment pedicle screw fixation A prospective randomised trial
    Jindal, N.
    Sankhala, S. S.
    Bachhal, V.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (08): : 1101 - 1106
  • [42] The Retrospective Analysis of Posterior Short-Segment Pedicle Instrumentation without Fusion for Thoracolumbar Burst Fracture with Neurological Deficit
    Deng, Zhouming
    Zou, Hui
    Cai, Lin
    Ping, Ansong
    Wang, Yongzhi
    Ai, Qiyong
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [43] BIOMECHANICAL ANALYSIS OF 3 SURGICAL APPROACHES FOR LUMBAR BURST FRACTURES USING SHORT-SEGMENT INSTRUMENTATION
    GURWITZ, GS
    DAWSON, JM
    MCNAMARA, MJ
    FEDERSPIEL, CF
    SPENGLER, DM
    SPINE, 1993, 18 (08) : 977 - 982
  • [44] Comparison of short-segment pedicle fixation with versus without inclusion of the fracture level in the treatment of mild thoracolumbar burst fractures
    Sun, Chao
    Guan, Guoping
    Liu, Xinhui
    Zhang, Hailong
    Wang, Bin
    INTERNATIONAL JOURNAL OF SURGERY, 2016, 36 : 352 - 357
  • [45] Instrumentation Removal following Minimally Invasive Posterior Percutaneous Pedicle Screw-Rod Stabilization (PercStab) of Thoracolumbar Fractures Is Not Always Required
    Manson, Neil
    El-Mughayyar, Dana
    Bigney, Erin
    Richardson, Eden
    Abraham, Edward
    ADVANCES IN ORTHOPEDICS, 2020, 2020
  • [46] Unilateral versus bilateral pedicle screw fixation in short-segment lumbar spinal fusion: a meta-analysis of randomised controlled trials
    Zengfeng Xin
    Weixu Li
    International Orthopaedics, 2016, 40 : 355 - 364
  • [47] Biomechanical comparison of mono-segment transpedicular fixation with short-segment fixation for treatment of thoracolumbar fractures: A finite element analysis
    Xu, Guijun
    Fu, Xin
    Du, Changling
    Ma, Jianxiong
    Li, Zhijun
    Tian, Peng
    Zhang, Tao
    Ma, Xinlong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (10) : 1005 - 1013
  • [48] Short segment percutaneous pedicle screw fixation after direct spinal canal decompression in thoracolumbar burst fractures: An alternative option
    Park, Seon-Ho
    Kim, Sang-Deok
    Moon, Bong Ju
    Lee, Shin-Seok
    Lee, Jung-Kil
    JOURNAL OF CLINICAL NEUROSCIENCE, 2018, 53 : 48 - 54
  • [49] Long versus short segment with intermediate screw fixation for burst fractures of thoracolumbar junction: radiological and clinical results
    Rispoli, Rossella
    Abousayed, Mahmoud
    Hamed, Alaa A.
    Cappelletto, Barbara
    JOURNAL OF NEUROSURGICAL SCIENCES, 2024, 68 (05) : 567 - 573
  • [50] Transpedicular Grafting After Short-Segment Pedicle Instrumentation for Thoracolumbar Burst Fracture Calcium Sulfate Cement Versus Autogenous Iliac Bone Graft
    Liao, Jen-Chung
    Fan, Kuo-Fon
    Keorochana, Gun
    Chen, Wen-Jer
    Chen, Lih-Hui
    SPINE, 2010, 35 (15) : 1482 - 1488