Biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures

被引:74
|
作者
Norton, Robert P. [1 ]
Milne, Edward L. [2 ]
Kaimrajh, David N. [2 ]
Eismont, Frank J. [1 ]
Latta, Loren L. [1 ,2 ]
Williams, Seth K. [3 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Orthopaed Surg, Miami, FL 33101 USA
[2] Mt Sinai Med Ctr, Max Biedermann Inst Biomech, Dept Res, Miami Beach, FL 33140 USA
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Orthopaed & Rehabil, Madison, WI 53705 USA
来源
SPINE JOURNAL | 2014年 / 14卷 / 08期
关键词
Short-segment fusion; Axial load fracture; Pedicle screw instrumentation; Spine fracture biomechanics; Spine fracture fixation; Thoracolumbar instrumentation; BURST FRACTURES; POSTERIOR INSTRUMENTATION; SPINE FRACTURES; IN-VIVO; INTERNAL-FIXATION; LUMBAR FUSION; LONG; ADJACENT; ANTERIOR; MODEL;
D O I
10.1016/j.spinee.2014.01.035
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Conventionally, short-segment fusion involves instrumentation of one healthy vertebra above and below the injured vertebra, skipping the injured level. This short-segment construct places less surgical burden on the patient compared with long-segment constructs, but is less stable biomechanically, and thus has resulted in clinical failures. The addition of two screws placed in the fractured vertebral body represents an attempt to improve the construct stiffness without sacrificing the benefits of short-segment fusion. PURPOSE: To determine the biomechanical differences between four-and six-screw short-segment constructs for the operative management of an unstable L1 fracture. STUDY DESIGN: Biomechanical study of instrumentation in vertebral body cadaveric models simulating an L1 axial load injury pattern. METHODS: Thirteen intact spinal segments from T12 to L2 were prepared from fresh-frozen cadaver spines. An axial load fracture of at least 50% vertebral body height was produced at L1 and then instrumented with pedicle screws. Specimens were evaluated in terms of construct stiffness, motion, and rod strain. Two conditions were tested: a four-screw construct with no screws at the L1 fractured body (4S) and a six-screw construct with screws at all levels (6S). The two groups were compared statistically by paired Student t test. RESULTS: The mean stiffness in flexion-extension was increased 31% (p < .03) with the addition of the two pedicle screws in L1. Relative motion in terms of vertical and axial rotations was not significantly different between the two groups. The L1-L2 rod strain was significantly increased in the six-screw construct compared with the four-screw construct (p < .001). CONCLUSIONS: In a cadaveric L1 axial load fracture model, a six-screw construct with screws in the fractured level is more rigid than a four-screw construct that skips the injured vertebral body. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1734 / 1739
页数:6
相关论文
共 50 条
  • [31] Posterior fixation of thoracolumbar burst fracture - Short-segment pedicle fixation versus long-segment instrumentation
    Tezeren, G
    Kuru, I
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 (06): : 485 - 488
  • [32] Treatment of Thoracolumbar Fractures Through Different Short Segment Pedicle Screw Fixation Techniques: A Finite Element Analysis
    Wang, Tie-nan
    Wu, Bao-lin
    Duan, Rui-meng
    Yuan, Ya-shuai
    Qu, Ming-jia
    Zhang, Shuo
    Huang, Wei
    Liu, Tao
    Yu, Xiao-bing
    ORTHOPAEDIC SURGERY, 2020, 12 (02) : 601 - 608
  • [33] Posterior short-segment fixation with implanting pedicle screw in the fractured level as a feasible method for treatment of thoracolumbar fracture
    Adawi, Mohammed Mustafa
    Aboulfetouh, Islam
    Saleh, Ahmed
    Younis, Walid
    EGYPTIAN JOURNAL OF NEUROSURGERY, 2019, 34 (01)
  • [34] Short-segment pedicle instrumentation of thoracolumbar burst-compression fractures; Short term follow-up results
    Shin, Tae-Sob
    Kim, Hyun-Woo
    Park, Keung-Suk
    Kim, Jae-Myung
    Jung, Chul-Ku
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2007, 42 (04) : 265 - 270
  • [35] Comparison of four-versus six-pedicle screw without fusion for thoracolumbar mono-segment compression fracture: removal implants more than 1 year
    Wang, Tao
    Wang, Hui
    Ding, Wen-Yuan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 9473 - 9478
  • [36] Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review
    Wang, Hongwei
    Zhao, Yiwen
    Mo, Zhongjun
    Han, Jianda
    Chen, Yu
    Yu, Hailong
    Wang, Qi
    Liu, Jun
    Li, Changqing
    Zhou, Yue
    Xiang, Liangbi
    CLINICS, 2017, 72 (10) : 609 - 617
  • [37] The Radiological Complications of Short-Segment Pedicle Screw Fixation Combined with Transforaminal Interbody Fusion in the Treatment of Unstable Thoracolumbar Burst Fracture: A Retrospective Case Series Study in Vietnam
    Ngoc Quyen Nguyen
    Trong Hau Phan
    ORTHOPEDIC RESEARCH AND REVIEWS, 2022, 14 : 91 - 99
  • [38] Biomechanical advantage of the index-level pedicle screw in unstable thoracolumbar junction fractures Presented at the 2010 Joint Spine Section Meeting Laboratory investigation
    Baaj, Ali A.
    Reyes, Phillip M.
    Yaqoobi, Ali S.
    Uribe, Juan S.
    Vale, Fernando L.
    Theodore, Nicholas
    Sonntag, Volker K. H.
    Crawford, Neil R.
    JOURNAL OF NEUROSURGERY-SPINE, 2011, 14 (02) : 192 - 197
  • [39] Unilateral versus bilateral pedicle screw fixation in short-segment lumbar spinal fusion: a meta-analysis of randomised controlled trials
    Xin, Zengfeng
    Li, Weixu
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (02) : 355 - 364
  • [40] Hybrid kyphoplasty with short-versus intermediate- and long-segment pedicle screw fixations for the management of thoracolumbar burst fractures
    Chou, Kuan-Nien
    Wang, Peng-Wei
    Chung, Ming-Hsuan
    Ju, Da-Tong