Biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures

被引:74
|
作者
Norton, Robert P. [1 ]
Milne, Edward L. [2 ]
Kaimrajh, David N. [2 ]
Eismont, Frank J. [1 ]
Latta, Loren L. [1 ,2 ]
Williams, Seth K. [3 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Orthopaed Surg, Miami, FL 33101 USA
[2] Mt Sinai Med Ctr, Max Biedermann Inst Biomech, Dept Res, Miami Beach, FL 33140 USA
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Orthopaed & Rehabil, Madison, WI 53705 USA
来源
SPINE JOURNAL | 2014年 / 14卷 / 08期
关键词
Short-segment fusion; Axial load fracture; Pedicle screw instrumentation; Spine fracture biomechanics; Spine fracture fixation; Thoracolumbar instrumentation; BURST FRACTURES; POSTERIOR INSTRUMENTATION; SPINE FRACTURES; IN-VIVO; INTERNAL-FIXATION; LUMBAR FUSION; LONG; ADJACENT; ANTERIOR; MODEL;
D O I
10.1016/j.spinee.2014.01.035
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Conventionally, short-segment fusion involves instrumentation of one healthy vertebra above and below the injured vertebra, skipping the injured level. This short-segment construct places less surgical burden on the patient compared with long-segment constructs, but is less stable biomechanically, and thus has resulted in clinical failures. The addition of two screws placed in the fractured vertebral body represents an attempt to improve the construct stiffness without sacrificing the benefits of short-segment fusion. PURPOSE: To determine the biomechanical differences between four-and six-screw short-segment constructs for the operative management of an unstable L1 fracture. STUDY DESIGN: Biomechanical study of instrumentation in vertebral body cadaveric models simulating an L1 axial load injury pattern. METHODS: Thirteen intact spinal segments from T12 to L2 were prepared from fresh-frozen cadaver spines. An axial load fracture of at least 50% vertebral body height was produced at L1 and then instrumented with pedicle screws. Specimens were evaluated in terms of construct stiffness, motion, and rod strain. Two conditions were tested: a four-screw construct with no screws at the L1 fractured body (4S) and a six-screw construct with screws at all levels (6S). The two groups were compared statistically by paired Student t test. RESULTS: The mean stiffness in flexion-extension was increased 31% (p < .03) with the addition of the two pedicle screws in L1. Relative motion in terms of vertical and axial rotations was not significantly different between the two groups. The L1-L2 rod strain was significantly increased in the six-screw construct compared with the four-screw construct (p < .001). CONCLUSIONS: In a cadaveric L1 axial load fracture model, a six-screw construct with screws in the fractured level is more rigid than a four-screw construct that skips the injured vertebral body. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1734 / 1739
页数:6
相关论文
共 50 条
  • [21] Short-Segment Fixation With Percutaneous Pedicle Screws in the Treatment of Unstable Thoracolumbar Vertebral Body Fractures
    Sahai, Nikil
    Faloon, Michael J.
    Dunn, Conor J.
    Issa, Kimona
    Sinha, Kumar
    Hwang, Ki Soo
    Emami, Arash
    ORTHOPEDICS, 2018, 41 (06) : E802 - E806
  • [22] Should the level of the posterior instrumentation combined with the intermediate screw be a short segment or a long segment in thoracolumbar fractures with fusion to the fractured segment?
    Suer, Onur
    Aydemir, Selahaddin
    Kilicli, Bunyamin
    Akcali, Omer
    Ozturk, Anil Murat
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2024, 50 (04) : 1753 - 1763
  • [23] Biomechanical Evaluation of Short-Segment Posterior Instrumentation With and Without Crosslinks in a Human Cadaveric Unstable Thoracolumbar Burst Fracture Model
    Wahba, George M.
    Bhatia, Nitin
    Bui, Christopher N. H.
    Lee, Kenneth H.
    Lee, Thay Q.
    SPINE, 2010, 35 (03) : 278 - 285
  • [24] Transpedicular Fixation in Management of Thoracolumbar Burst Fractures Monosegmental Fixation Versus Short-Segment Instrumentation
    Wei, Fu-Xin
    Liu, Shao-Yu
    Liang, Chun-Xiang
    Li, Hao-Miao
    Long, Hou-Qing
    Yu, Bin-Sheng
    Chen, Bai-Ling
    Chen, Ke-Bing
    SPINE, 2010, 35 (15) : E714 - E720
  • [25] Pedicle screw fixation of thoracolumbar fractures: conventional short segment versus short segment with intermediate screws at the fracture level-a systematic review and meta-analysis
    Kapoen, Carolijn
    Liu, Yang
    Bloemers, Frank W.
    Deunk, Jaap
    EUROPEAN SPINE JOURNAL, 2020, 29 (10) : 2491 - 2504
  • [26] Short segment pedicle screw instrumentation and augmentation vertebroplasty in lumbar burst fractures: an experience
    Afzal, Suhail
    Akbar, Saleem
    Dhar, Shabir A.
    EUROPEAN SPINE JOURNAL, 2008, 17 (03) : 336 - 341
  • [27] Short segment pedicle screw instrumentation and augmentation vertebroplasty in lumbar burst fractures: an experience
    Suhail Afzal
    Saleem Akbar
    Shabir A. Dhar
    European Spine Journal, 2008, 17 : 336 - 341
  • [28] Retrospective analysis of treatment of thoracolumbar burst fracture using mono-segment pedicle instrumentation compared with short-segment pedicle instrumentation
    Li, Xilei
    Ma, Yiqun
    Dong, Jian
    Zhou, Xiao-gang
    Li, Juan
    EUROPEAN SPINE JOURNAL, 2012, 21 (10) : 2034 - 2042
  • [29] Treatment of thoracolumbar burst fractures by short-segment pedicle screw fixation using a combination of two additional pedicle screws and vertebroplasty at the level of the fracture: a finite element analysis
    Jen-Chung Liao
    Weng-Pin Chen
    Hao Wang
    BMC Musculoskeletal Disorders, 18
  • [30] Treatment of thoracolumbar burst fractures by short-segment pedicle screw fixation using a combination of two additional pedicle screws and vertebroplasty at the level of the fracture: a finite element analysis
    Liao, Jen-Chung
    Chen, Weng-Pin
    Wang, Hao
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18