The Feasibility of a Smart Surgical Probe for Verification of IRE Treatments Using Electrical Impedance Spectroscopy

被引:24
作者
Bonakdar, Mohammad [1 ,2 ]
Latouche, Eduardo L. [2 ]
Mahajan, Roop L. [3 ]
Davalos, Rafael V. [4 ]
机构
[1] Virginia Tech, Ctr Intelligent Mat Syst & Struct, Blacksburg, VA 24060 USA
[2] Virginia Tech, Bioelectromech Syst Lab, Blacksburg, VA 24060 USA
[3] Virginia Tech, Inst Crit Technol & Appl Sci, Blacksburg, VA 24060 USA
[4] Virginia Tech, Dept Biomed Engn & Mech, Blacksburg, VA 24060 USA
基金
美国国家科学基金会;
关键词
Abl(a)tion monitoring; electrochemotherapy (ECT); focal ablation; impedance sensor; irreversible electroporation (IRE); microfabrication; IRREVERSIBLE ELECTROPORATION; IN-VIVO; TUMOR ABLATION; TISSUE ELECTROPORATION; DIELECTRIC EVOLUTION; CONDUCTIVITY CHANGES; THERMAL ABLATION; REAL-TIME; TOMOGRAPHY; MONITOR;
D O I
10.1109/TBME.2015.2441636
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Significance: Irreversible electroporation (IRE) is gaining popularity as a focal ablation modality for the treatment of unresectable tumors. One clinical limitation of IRE is the absence of methods for real-time treatment evaluation, namely actively monitoring the dimensions of the induced lesion. This information is critical to ensure a complete treatment and minimize collateral damage to the surrounding healthy tissue. Goal: In this study, we are taking advantage of the biophysical properties of living tissues to address this critical demand. Methods: Using advanced microfabrication techniques, we have developed an electrical impedance microsensor to collect impedance data along the length of a bipolar IRE probe for treatment verification. For probe characterization and interpretation of the readings, we used potato tuber, which is a suitable platform for IRE experiments without having the complexities of in vivo or ex vivo models. We used the impedance spectra, along with an electrical model of the tissue, to obtain critical parameters such as the conductivity of the tissue before, during, and after completion of treatment. To validate our results, we used a finite element model to simulate the electric field distribution during treatments in each potato. Results: It is shown that electrical impedance spectroscopy could be used as a technique for treatment verification, and when combined with appropriate FEM modeling can determine the lesion dimensions. Conclusions: This technique has the potential to be readily translated for use with other ablation modalities already being used in clinical settings for the treatment of malignancies.
引用
收藏
页码:2674 / 2684
页数:11
相关论文
共 67 条
[21]   A Parametric Study Delineating Irreversible Electroporation from Thermal Damage Based on a Minimally Invasive Intracranial Procedure [J].
Garcia, Paulo A. ;
Rossmeisl, John H., Jr. ;
Neal, Robert E., II ;
Ellis, Thomas L. ;
Davalos, Rafael V. .
BIOMEDICAL ENGINEERING ONLINE, 2011, 10
[22]   A new spiral microelectrode assembly for electroporation and impedance measurements of adherent cell monolayers [J].
Garcia-Sanchez, Tomas ;
Guitart, Maria ;
Rosell-Ferrer, Javier ;
Gomez-Foix, Anna M. ;
Bragos, Ramon .
BIOMEDICAL MICRODEVICES, 2014, 16 (04) :575-590
[23]   USE OF ELECTRIC-FIELDS TO MONITOR THE DYNAMIC ASPECT OF CELL BEHAVIOR IN TISSUE-CULTURE [J].
GIAEVER, I ;
KEESE, CR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) :242-247
[24]   Thermal ablation therapy for focal malignancy: A unified approach to underlying principles, techniques, and diagnostic imaging guidance [J].
Goldberg, SN ;
Gazelle, GS ;
Mueller, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :323-331
[25]   In vivo imaging of irreversible electroporation by means of electrical impedance tomography [J].
Granot, Yair ;
Ivorra, Antoni ;
Maor, Elad ;
Rubinsky, Boris .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (16) :4927-4943
[26]   In vivo electroporation for gene therapy [J].
Heller, Loree C. ;
Heller, Richard .
HUMAN GENE THERAPY, 2006, 17 (09) :890-897
[27]   Magnetic Resonance Imaging Characteristics of Nonthermal Irreversible Electroporation in Vegetable Tissue [J].
Hjouj, Mohammad ;
Rubinsky, Boris .
JOURNAL OF MEMBRANE BIOLOGY, 2010, 236 (01) :137-146
[28]   Micro-Electroporation: Improving the Efficiency and Understanding of Electrical Permeabilization of Cells [J].
Huang, Yong ;
Rubinsky, Boris .
BIOMEDICAL MICRODEVICES, 1999, 2 (02) :145-150
[29]   Bioimpedance dispersion width as a parameter to monitor living tissues [J].
Ivorra, A ;
Genescà, M ;
Sola, A ;
Palacios, L ;
Villa, R ;
Hotter, G ;
Aguiló, J .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (02) :S165-S173
[30]   Minimally invasive silicon probe for electrical impedance measurements in small animals [J].
Ivorra, A ;
Gómez, R ;
Noguera, N ;
Villa, R ;
Sola, A ;
Palacios, L ;
Hotter, G ;
Aguiló, J .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (04) :391-399