Comparison of renal dynamic imaging and two plasma sample method in determining glomerular filtration rate in patients with diabetic nephropathy

被引:0
|
作者
Li, Ming-Hao [1 ]
Jiang, Nan [1 ]
机构
[1] Yanbian Univ Hosp China, Dept Nucl Med, 1327 Ju Zi St, Yanji 133000, Jilin, Peoples R China
来源
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE | 2016年 / 9卷 / 10期
关键词
Renal dynamic imaging; two plasma sample (TPS) method; glomerular filtration rate; diabetic nephropathy; CHRONIC KIDNEY-DISEASE; CHINESE PATIENTS; SCINTIGRAPHY; CLEARANCE; EQUATION;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: This study aims to compare the application significance of renal dynamic imaging (RDI) and two plasma sample (TPS) method in determining glomerular filtration rate (GFR) in patients with diabetic nephropathy. Methods: A total of 68 patients who received medical service in the Endocrinology Department of our hospital were enrolled into this study. These patients were divided into three groups: early nephropathy group (DN1 group, n=23), clinical nephropathy group (DN2 group, n=23) and uremia group (DN3 group, n=22). In addition, 22 healthy subjects were enrolled and assigned as control group (DN0 group). GFRs of all subjects were determined by both RDI and TPS method, and the correlation between results and determination methods were analyzed. Results: GFRs (gGFRs and tGFRs) in the DN0, DN1 and DN2 groups were determined by RDI and TPS, and the difference was not statistically significant (P> 0.05). Differences between gGFR and tGFR in the DN3 group was statistically significant (P< 0.05). Correlation coefficients between GFRs determined by RDI and TPS in the DN0, DN1, DN2 and DN3 groups were 0.999, 0.947, 0.925 and 0.999, respectively. All values exhibited a significant positive correlation (P< 0.05). Conclusions: Both RDI and TPS can sensitively reveal GFR changes in early and clinical nephropathy. However, RDI revealed poor accuracy and low sensitivity in the diagnosis of diabetic nephropathy in the uremic phase, and medical history combined with other examination methods should be applied in the diagnosis.
引用
收藏
页码:19919 / 19924
页数:6
相关论文
共 50 条
  • [31] Stabilization of glomerular filtration rate over 2 years in patients with diabetic nephropathy under intensified therapy regimes
    Sawicki, PT
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1997, 12 (09) : 1890 - 1899
  • [32] Glomerular filtration rate measured by 99mTc-DTPA renal dynamic imaging is significantly lower than that estimated by the CKD-EPI equation in horseshoe kidney patients
    Qi, Yan
    Hu, Panpan
    Xie, Yuansheng
    Wei, Kai
    Jin, Meiling
    Ma, Guangyu
    Li, Qinggang
    Xu, Baixuan
    Chen, Xiangmei
    NEPHROLOGY, 2016, 21 (06) : 499 - 505
  • [33] A comparison of measured and estimated glomerular filtration rate in successfully treated HIV-patients with preserved renal function
    Vrouenraets, Saskia M. E.
    Fux, Christoph A.
    Wit, Ferdinand W. N. M.
    Garcia, Evian Fernandez
    Brinkman, Kees
    Hoek, Frans J.
    van Straalen, Jan P.
    Furrer, Hansjakob
    Krediet, Ray T.
    Reiss, Peter
    CLINICAL NEPHROLOGY, 2012, 77 (04) : 311 - 320
  • [34] Comparison of Four Methods for Measuring Glomerular Filtration Rate by Inulin Clearance in Healthy Individuals and Patients with Renal Failure
    Hernandez Ocampo, J.
    Torres Rosales, A.
    Rodriguez Castellanos, F.
    NEFROLOGIA, 2010, 30 (03): : 324 - 330
  • [35] A comparison of different methods for the determination of glomerular filtration rate in elderly patients with chronic renal failure
    Beyza Macunluoğlu
    İbrahim Gökçe
    Aydın Atakan
    Münir Demirci
    Elif Arı
    Ahmet Topuzoğlu
    Ali Borazan
    International Urology and Nephrology, 2011, 43 : 257 - 263
  • [36] Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
    Itoh, K
    ANNALS OF NUCLEAR MEDICINE, 2003, 17 (07) : 561 - 565
  • [37] Comparison of glomerular filtration rate measurements with the two-plasma sample technique using Tc-99m DTPA and other methods in donor candidates for renal transplantation
    Ayan, Arif Kursad
    Varoglu, Erhan
    Keles, Mustafa
    Seven, Bedri
    Uyanik, Abdullah
    Orsal, Ebru
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2016, 46 (04) : 1025 - 1032
  • [38] Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
    Kazuo Itoh
    Annals of Nuclear Medicine, 2003, 17 : 561 - 565
  • [39] Microbial imidazole propionate affects glomerular filtration rate in patients with diabetic nephropathy through association with HSP90α
    Lv, Dan
    Zheng, Wenhan
    Zhang, Zheng
    Lin, Ziyue
    Wu, Keqian
    Liu, Handeng
    Liao, Xiaohui
    Sun, Yan
    BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR CELL RESEARCH, 2024, 1871 (04):
  • [40] Nephrotoxicity of CDDP Assessed Estimating Glomerular Filtration Rate With 99mTc-DTPA Plasma Sample Method
    Fatima, Nosheen
    Niaz, Khalid
    Maseeh-Uz-Zaman
    Kamal, Shahid
    Hameed, Abid
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2010, 20 (02): : 98 - 101