摘要
Purpose The dosimetric properties of inverse Compton (IC) x-ray sources were investigated to determine their utility for stereotactic radiation therapy. Methods Monte Carlo simulations were performed using the egs brachy user code of EGSnrc. Nominal IC source x-ray energies of 80 and 150 keV were considered in this work. Depth-dose and lateral dose profiles in water were calculated, as was dose enhancement in the bone. Further simulations were performed for brain and spine treatment sites. The impact of gold nanoparticle doping was also investigated for the brain treatment site. Analogous dose calculations were performed in a clinical treatment planning system using a clinical 6 MV photon beam model and were compared to the Monte Carlo simulations. Results Both 80 and 150 keV IC beams were observed to have sharp 80-20 penumbra (i.e., < 0.1 mm) with broad low-dose tails in water. For reference, the calculated penumbra for the 6 MV clinical beam was 3 mm. Maximum dose enhancement factors in bone of 3.1, 1.4, and 1.1 were observed for the 80, 150 keV, and clinical 6 MV beams, respectively. The plan quality for the single brain metastasis case was similar between the IC beams and the 6 MV beam without gold nanoparticles. As the concentration of gold within the target increased, the V12 Gy to the normal brain tissue and Dmax within the target volume significantly decreased and the conformity significantly improved, which resulted in superior plan quality over the clinical 6 MV beam plan. In the spine cases, the sharp penumbra and enhanced dose to bone of the IC beams produced superior plan quality (i.e., better conformity, normal tissue sparing, and spinal cord sparing) as compared to the clinical 6 MV beam plans. Conclusions The findings from this work indicate that inverse Compton x-ray sources are well suited for stereotactic radiotherapy treatments due to their sharp penumbra and dose enhancement around high atomic number materials. Future work includes investigating the properties of intensity-modulated inverse Compton x-ray sources to improve the homogeneity within the target tissue.
引用
收藏
页码:366 / 375
页数:10
相关论文
共 37 条
  • [1] Bruni C, 2011, UVX 2010 10 C SOURC, P49
  • [2] egs_brachy: a versatile and fast Monte Carlo code for brachytherapy
    Chamberland, Marc J. P.
    Taylor, Randle E. P.
    Rogers, D. W. O.
    Thomson, Rowan M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (23) : 8214 - 8231
  • [3] Estimation of tumour dose enhancement due to gold nanoparticles during typical radiation treatments: a preliminary Monte Carlo study
    Cho, SH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (15) : N163 - N173
  • [4] Vertebral Compression Fracture (VCF) After Spine Stereotactic Body Radiation Therapy (SBRT): Analysis of Predictive Factors
    Cunha, Marcelo V. R.
    Al-Omair, Ameen
    Atenafu, Eshetu G.
    Masucci, Giuseppina Laura
    Letourneau, Daniel
    Korol, Renee
    Yu, Eugene
    Howard, Peter
    Lochray, Fiona
    da Costa, Leodante B.
    Fehlings, Michael G.
    Sahgal, Arjun
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : E343 - E349
  • [5] High-brilliance, high-flux compact inverse Compton light source
    Deitrick, K. E.
    Krafft, G. A.
    Terzic, B.
    Delayen, J. R.
    [J]. PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2018, 21 (08):
  • [6] A proof of principle experiment for microbeam radiation therapy at the Munich compact light source
    Dombrowsky, Annique C.
    Burger, Karin
    Porth, Ann-Kristin
    Stein, Marlon
    Dierolf, Martin
    Guenther, Benedikt
    Achterhold, Klaus
    Gleich, Bernhard
    Feuchtinger, Annette
    Bartzsch, Stefan
    Beyreuther, Elke
    Combs, Stephanie E.
    Pfeiffer, Franz
    Wilkens, Jan J.
    Schmid, Thomas E.
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2020, 59 (01) : 111 - 120
  • [7] Faster and safer? FLASH ultra-high dose rate in radiotherapy
    Durante, Marco
    Brauer-Krisch, Elke
    Hill, Mark
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1082)
  • [8] X-ray phase-contrast tomography with a compact laser-driven synchrotron source
    Eggl, Elena
    Schleede, Simone
    Bech, Martin
    Achterhold, Klaus
    Loewen, Roderick
    Ruth, Ronald D.
    Pfeiffer, Franz
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2015, 112 (18) : 5567 - 5572
  • [9] Status of Compact Inverse Compton Sources in Italy: BriXS and STAR.
    Faillace, L.
    Agostino, R. G.
    Bacci, A.
    Barberi, R.
    Bosotti, A.
    Broggi, F.
    Cardarelli, P.
    Cialdi, S.
    Drebot, I.
    Formoso, V.
    Gambaccini, M.
    Ghedini, G.
    Giannotti, D.
    Giove, D.
    Martire, F.
    Mettivier, G.
    Michelato, P.
    Monaco, L.
    Paparella, R.
    Paterno, G.
    Petrillo, V.
    Prelz, F.
    Puppin, Ezio
    Conti, M. Rossetti
    Rossi, A. R.
    Russo, P.
    Sarno, A.
    Sertore, D.
    Taibi, A.
    Serafini, L.
    [J]. ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS VII, 2019, 11110
  • [10] An inverse free electron laser acceleration-driven Compton scattering X-ray source
    Gadjev, I.
    Sudar, N.
    Babzien, M.
    Duris, J.
    Hoang, P.
    Fedurin, M.
    Kusche, K.
    Malone, R.
    Musumeci, P.
    Palmer, M.
    Pogorelsky, I.
    Polyanskiy, M.
    Sakai, Y.
    Swinson, C.
    Williams, O.
    Rosenzweig, J. B.
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)