In order to improve the biocompatibility of metallic implants, bioactive components are often used as coatings so that a real bond with the surrounding bone tissue can be formed. We prepared ethyl cellulose/carbonated hydroxyapatite composite coatings (ECHCs) on Ti6Al4V substrates with carbonated hydroxyapatite coatings (CHACs) without ethyl cellulose as controls. The inorganic constituent on the CHACs and ECHCs is calcium-deficient carbonated hydroxyapatite with a flaky texture and a low degree of crystallinity. The flaky carbonated hydroxyapatite plates aggregate to form macropores with an aperture size of around 0.5-2.0 mu m. The presence of ethyl cellulose provides superior morphology, contact angle, and biocompatibility characteristics. In comparison to CHACs, ECHCs exhibit a smoother, crack-free surface because the cracks are filled by ethyl cellulose. Moreover, the contact angle of ECHCs is 37.3A degrees, greater than that of CHACs (13.0A degrees). Surface biocompatibility was investigated by using human bone mesenchymal stem cells (hBMSCs). The attachment, spreadability, viability and proliferation of hBMSCs on ECHCs are superior to those on CHACs. Thus, the crack-free ECHCs have excellent biocompatibility and are appropriate for use as biological implants.
机构:
Hong Kong Polytech Univ, Dept Ind & Syst Engn, Hong Kong, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Dept Appl Phys, Hong Kong, Hong Kong, Peoples R China
机构:
Washington State Univ, WM Keck Biomed Mat Res Lab, Sch Mech & Mat Engn, Pullman, WA 99164 USAWashington State Univ, WM Keck Biomed Mat Res Lab, Sch Mech & Mat Engn, Pullman, WA 99164 USA
Balla, Vamsi Krishna
Bhat, Abhimanyu
论文数: 0引用数: 0
h-index: 0
机构:
Washington State Univ, WM Keck Biomed Mat Res Lab, Sch Mech & Mat Engn, Pullman, WA 99164 USAWashington State Univ, WM Keck Biomed Mat Res Lab, Sch Mech & Mat Engn, Pullman, WA 99164 USA
Bhat, Abhimanyu
Bose, Susmita
论文数: 0引用数: 0
h-index: 0
机构:
Washington State Univ, WM Keck Biomed Mat Res Lab, Sch Mech & Mat Engn, Pullman, WA 99164 USAWashington State Univ, WM Keck Biomed Mat Res Lab, Sch Mech & Mat Engn, Pullman, WA 99164 USA
Bose, Susmita
Bandyopadhyay, Amit
论文数: 0引用数: 0
h-index: 0
机构:
Washington State Univ, WM Keck Biomed Mat Res Lab, Sch Mech & Mat Engn, Pullman, WA 99164 USAWashington State Univ, WM Keck Biomed Mat Res Lab, Sch Mech & Mat Engn, Pullman, WA 99164 USA
机构:
Univ Teknol Malaysia, Fac Biosci & Bioengn, Med Implant Technol Grp, Utm Johor Bahru 81310, Johor, Malaysia
Int Islamic Univ Malaysia, Kuantan 25200, MalaysiaUniv Teknol Malaysia, Fac Biosci & Bioengn, Med Implant Technol Grp, Utm Johor Bahru 81310, Johor, Malaysia
Yusoff, Mohd Faiz Mohd
Kadir, Mohammed Rafiq Abdul
论文数: 0引用数: 0
h-index: 0
机构:
Univ Teknol Malaysia, Fac Biosci & Bioengn, Med Implant Technol Grp, Utm Johor Bahru 81310, Johor, MalaysiaUniv Teknol Malaysia, Fac Biosci & Bioengn, Med Implant Technol Grp, Utm Johor Bahru 81310, Johor, Malaysia
Kadir, Mohammed Rafiq Abdul
Iqbal, Nida
论文数: 0引用数: 0
h-index: 0
机构:
Univ Teknol Malaysia, Fac Biosci & Bioengn, Med Implant Technol Grp, Utm Johor Bahru 81310, Johor, MalaysiaUniv Teknol Malaysia, Fac Biosci & Bioengn, Med Implant Technol Grp, Utm Johor Bahru 81310, Johor, Malaysia
Iqbal, Nida
Hassan, Mas Ayu
论文数: 0引用数: 0
h-index: 0
机构:
Univ Malaysia Pahang, Fac Mech Engn, Pekan 26600, Pahang, MalaysiaUniv Teknol Malaysia, Fac Biosci & Bioengn, Med Implant Technol Grp, Utm Johor Bahru 81310, Johor, Malaysia
Hassan, Mas Ayu
Hussain, Rafaqat
论文数: 0引用数: 0
h-index: 0
机构:
Univ Teknol Malaysia, Ibnu Sina Inst Fundamental Sci Studies, Utm Johor Bahru 81310, Johor, MalaysiaUniv Teknol Malaysia, Fac Biosci & Bioengn, Med Implant Technol Grp, Utm Johor Bahru 81310, Johor, Malaysia