Titanium Niobium Nitride Mobile-Bearing Unicompartmental Knee Arthroplasty Results in Good to Excellent Clinical and Radiographic Outcomes in Metal Allergy Patients With Medial Knee Osteoarthritis

被引:11
作者
D'Ambrosi, Riccardo [1 ]
Nuara, Alessandro [1 ,2 ]
Mariani, Ilaria [3 ]
Di Feo, Fabrizio [1 ]
Ursino, Nicola [1 ]
Hirschmann, Michael [4 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, Via Galeazzi 4, I-20161 Milan, Italy
[2] Univ Milan, Milan, Italy
[3] Univ Milano Bicocca, Milan, Italy
[4] Kantonsspital Baselland, Dept Orthopaed Surg & Traumatol, Baselland, Switzerland
关键词
unicompartmental knee arthroplasty; unicondylar; hypoallergenic; metal hypersensitivity; mobile bearing; TiNbN; SURGICAL INSTRUMENTATION; OXIDIZED ZIRCONIUM; FEMORAL COMPONENTS; HYPERSENSITIVITY; POLYETHYLENE; IMPLANTS; REVISION; RISK; WEAR; HIP;
D O I
10.1016/j.arth.2020.07.028
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The main purpose of the present study was to analyze the clinical and radiological outcomes of patients with positive skin patch tests who underwent medial mobile-bearing titanium niobium nitride unicompartmental knee arthroplasty (UKA) during a mid-term follow-up. Methods: Thirty-seven patients with positive skin patch tests were included in this prospective study. The clinical evaluation consisted of Oxford Knee Score and Knee Society Score (KSS) reports. Each patient was clinically evaluated the day before surgery (T-0) as well as at T-1 (11.9 +/- 1.3 months) and during the final follow-up T-2 (67.2 +/- 19.1 months). The positioning of the UKA was evaluated during the final follow-up using standardized radiographs (T-2 : 67.2 +/- 19.1 months). Results: Oxford and KSS ranged from a respective mean preoperative value of 23.0 +/- 2.7 and 51.5 +/- 5.0 to 42.1 +/- 1.7 and 87.6 +/- 2.2, respectively, at T-1 (P < .001) and to the final values of 45.0 +/- 1.9 and 91.9 +/- 3.4, respectively, at T-2 (P < .001 both vs T-1 and T-2). At T-2, the mean femoral angle was 7.0 degrees +/- 4.5 degrees, mean tibial angle was 3.0 degrees +/- 2.1 degrees, and mean tibial slope was 5.1 degrees +/- 3.2 degrees. A significant difference was found between KSS and Oxford with ANOVA for repeated measures over time (P < .001). The Oxford and KSS scores showed significant improvements during each follow-up. No complications were found, and not a single patient required a revision surgery during the follow-up period. Conclusion: The hypoallergenic titanium niobium nitride mobile-bearing UKA showed comparable results to standard CoCr UKA regardless of the gender, age, BMI, and implant size of metal allergy patients with medial knee osteoarthritis. Careful patient selection processes and accurate medical histories played key roles in the choice of hypersensitivity-friendly implants. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:140 / +
页数:10
相关论文
共 45 条
  • [1] Metal allergy in total-joint arthroplasty Case report and literature review
    Bao, Wei
    He, Yao
    Fan, Yuanjun
    Liao, Yueming
    [J]. MEDICINE, 2018, 97 (38)
  • [2] Midterm Results After Coated and Uncoated TKA: A Randomized Controlled Study
    Beyer, Franziska
    Luetzner, Cornelia
    Kirschner, Stephan
    Luetzner, Joerg
    [J]. ORTHOPEDICS, 2016, 39 (03) : S13 - S17
  • [3] No Increased Risk of Knee Arthroplasty Failure in Patients With Positive Skin Patch Testing for Metal Hypersensitivity: A Matched Cohort Study
    Bravo, Dalibel
    Wagner, Eric R.
    Larson, Dirk R.
    Davis, Mark P.
    Pagnano, Mark W.
    Sierra, Rafael J.
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (08) : 1717 - 1721
  • [4] Minimum 10-year outcomes of a fixed bearing all-polyethylene unicompartmental knee arthroplasty used to treat medial osteoarthritis
    Bruce, David J.
    Hassaballa, Mohammed
    Robinson, James R.
    Porteous, Andrew J.
    Murray, James R.
    Newman, John H.
    [J]. KNEE, 2020, 27 (03) : 1018 - 1027
  • [5] Mid-term survivorship and patient-reported outcomes of robotic-arm assisted partial knee arthroplasty A SINGLE-SURGEON STUDY OF 1,018 KNEES
    Burger, J. A.
    Kleeblad, L. J.
    Laas, N.
    Pearle, A. D.
    [J]. BONE & JOINT JOURNAL, 2020, 102B (01) : 108 - 116
  • [6] Cho Kye-Youl, 2018, Knee Surg Relat Res, V30, P23, DOI 10.5792/ksrr.17.042
  • [7] Prevalence of metal hypersensitivity in total knee replacement
    Desai, Mohan M.
    Shah, Kunal Ajitkumar
    Mohapatra, Anuradha
    Patel, Digen C.
    [J]. JOURNAL OF ORTHOPAEDICS, 2019, 16 (06) : 468 - 472
  • [8] Mid-term Clinical and Radiological Results of Oxford Phase 3 Medial Unicompartmental Knee Arthroplasty
    Erdem, Yusuf
    Neyisci, Cagri
    Yildiz, Cemil
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (09)
  • [9] Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator
    Ezzet, KA
    Hermida, JC
    Colwell, CW
    D'Lima, DD
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) : 120 - 124
  • [10] Faschingbauer Martin, 2017, HSS J, V13, P12, DOI 10.1007/s11420-016-9514-8