Objective: We compared blood glucose measurements at the thenar with those at the fingertip during glucose increase and decrease that was rapid enough to induce glucose differences between the forearm and the fingertip. Methods: A rapid glucose increase was induced by oral glucose; subsequently, a rapid glucose decrease was induced by intravenous insulin in 16 insulin-treated patients with diabetes. Capillary samples were taken in parallel from the thenar and fingertip. Different glucose monitors (FreeStyle(TM), OneTouch(R)Ultra, Soft-Sense T) were used. Additional samples were taken from the forearm (n = 10 patients) in order to demonstrate that the blood glucose change achieved was rapid enough to principally induce glucose differences at alternative sites. Results: Neither blood glucose at baseline (135 +/- 34 vs. 136 +/- 41 mg/dl, p = 0.86) nor glucose amplitude during increase (190 +/- 35 vs. 188 +/- 41 mg/dl, p = 0.65) or decrease (255 +/- 32 vs. 257 +/- 45 mg/dl, p = 0.83) differed significantly between the fingertip and the thenar. Intra-individual average thenar-fingertip glucose difference was -2 +/- 12 (p = 1.00) and +5 +/- 9 mg/dl (p = 0.11). In the subgroup, intra-individual average forearm-finger difference was -50 +/- 19 (p<0.01) and +45 ± 11 mg/dl (p < 0.01) during glucose-increase and decrease, respectively. There were no obvious device-specific differences. Conclusions: Blood glucose measurements at the thenar are a safe alternative to measurements at the fingertip at steady state as well as during blood glucose change that is sufficiently rapid to induce clinically relevant differences between forearm and fingertip.
引用
收藏
页码:325 / 329
页数:5
相关论文
共 50 条
  • [1] Blood glucose monitoring at the thenar matches the results at the fingertip even during rapid blood glucose changes
    Jungheim, K
    Koschinsky, T
    DIABETES, 2002, 51 : A123 - A123
  • [2] Effect of increased blood glucose availability on glucose kinetics during exercise
    Howlett, K
    Angus, D
    Proietto, J
    Hargreaves, M
    JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (04) : 1413 - 1417
  • [3] Blood glucose monitoring
    Holt, RIG
    DIABETES OBESITY & METABOLISM, 2005, 7 (05): : 619 - 620
  • [4] Evaluation of CGMS® during rapid blood glucose changes in patients with type 1 diabetes
    Wilhelm, Birgit
    Forst, Senait
    Weber, Matthias M.
    Larbig, Martin
    Pfuetzner, Andreas
    Forst, Thomas
    DIABETES TECHNOLOGY & THERAPEUTICS, 2006, 8 (02) : 146 - 155
  • [5] Comparison in the Performance of Glucose Meters in Blood Glucose Monitoring during Pregnancy
    Kong, Grace Wing Shan
    Tam, Wing Hung
    Chan, Michael Ho Ming
    So, Wing Yee
    Lam, Christopher Wai Kei
    Yiu, Ivy Po Chu
    Loo, Kit Man
    Li, Chi Yin
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 2010, 69 (04) : 264 - 269
  • [6] URINE GLUCOSE ANALYSES DURING CONTINUOUS BLOOD-GLUCOSE MONITORING
    SERVICE, FJ
    TAYLOR, WF
    MOLNAR, GD
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1972, 222 (03): : 294 - &
  • [7] CONTINUOUS MONITORING OF BLOOD GLUCOSE DURING IV GLUCOSE TOLERANCE TEST
    BROWN, GM
    QUARRING.B
    STANCER, HC
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1966, 94 (13) : 660 - &
  • [8] EVALUATION OF A RAPID METHOD FOR BLOOD GLUCOSE DETERMINATION
    TRAISMAN, HS
    NEWCOMB, AL
    ILLINOIS MEDICAL JOURNAL, 1961, 120 (02): : 90 - &
  • [9] BLOOD LIPID GLUCOSE AND BLOOD-GLUCOSE CHANGES DURING SINGLE, MULTIPLE AND REPEATED STRESS
    CERVINKA, R
    KOLLER, M
    HAIDER, M
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1980, 43 (03) : 201 - 212
  • [10] Evaluation of blood glucose fluctuation in Japanese patients with type 1 diabetes mellitus by self-monitoring of blood glucose and continuous glucose monitoring
    Kusunoki, Yoshiki
    Katsuno, Tomoyuki
    Nakae, Rie
    Watanabe, Kahori
    Akagami, Takafumi
    Ochi, Fumihiro
    Tokuda, Masaru
    Murai, Kazuki
    Miuchi, Masayuki
    Miyagawa, Jun-ichiro
    Namba, Mitsuyoshi
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2015, 108 (02) : 342 - 349