Endometrial volume measured on the day of embryo transfer is not associated with live birth rates in IVF: A prospective study and review of the literature

被引:7
作者
Boza, Aysen [1 ,2 ]
Oznur, Dundar Akin [3 ]
Mehmet, Ceyhan [1 ,2 ]
Gulumser, Aksakal [1 ,2 ]
Bulent, Urman [1 ,2 ]
机构
[1] Amer Hosp, Womens Hlth Ctr, Istanbul, Turkey
[2] Amer Hosp, Assisted Reprod Unit, Istanbul, Turkey
[3] Mem Hosp, Assisted Reprod Unit, Istanbul, Turkey
关键词
Endometrial volume; Three-dimensional ultrasonography; Embryo implantation; Live birth; IN-VITRO FERTILIZATION; POWER DOPPLER ANGIOGRAPHY; TRANSVAGINAL 3-DIMENSIONAL ULTRASONOGRAPHY; VASCULARITY MEASUREMENTS; TUMORAL ENDOMETRIA; ULTRASOUND; RECEPTIVITY; PREDICTOR;
D O I
10.1016/j.jogoh.2020.101767
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To evaluate the effect of endometrial volume (EV) on the live birth rates (LBR)s in fresh or frozen embryo transfer (ET) cycles. Material and methods: This is a prospective study including all women who underwent a fresh or frozen single blastocyst transfer between January 2017 and September 2018 in a university affiliated private hospital. Patients with advanced age (>42years), congenital uterine anomalies, endometrial or myometrial abnormalities, those with a difficult ET, those with only poor-quality blastocysts available for transfer, those in whom an optimal 3D TVUS image could not be obtained and those who were lost to follow-up were excluded. Endometrial volume was assessed using Virtual Organ Computer Aided Analysis program immediately prior to ET by two different observers using a standardized technique. The association of ET outcome and EV was evaluated by receiver operating characteristics (ROC) curve and logistic regression analysis. Results: A total of 142 patients were included in the final analysis. Patients were grouped according the EV percentiles (p); 5thp (1.7 mL), 10thp (2.2 mL), 25thp (2.9 mL), 50thp (4.3 mL) and >75thp (>5.3 mL) groups. ROC curve analysis was not predictive of LBRs, with an AUC (95 % CI) = 0.48 (0.38-0.58). There was no critical threshold, below which pregnancy was unlikely to occur. No significant association was observed between EV and any of the evaluated clinical outcomes. Conclusion(s): When controlled for potential confounders, EV assessed by 3D TVUS is not a useful tool for predicting pregnancy in single blastocyst ET cycles. (C) 2020 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:6
相关论文
共 15 条
[1]  
Aboulghar M., 2005, Middle East Fertility Society Journal, V10, P63
[2]   Endometrial volume and vascularity measurements by transvaginal 3-dimensional ultrasonography and power Doppler angiography in stimulated and tumoral endometria -: An interobserver reproducibility study [J].
Alcázar, JL ;
Mercé, LT ;
Manero, MG ;
Bau, S ;
López-García, G .
JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (08) :1091-1098
[3]   Randomized comparison of two different blastocyst grading systems [J].
Balaban, B ;
Yakin, K ;
Urman, B .
FERTILITY AND STERILITY, 2006, 85 (03) :559-563
[4]   How should we choose the 'best' embryo? A commentary on behalf of the British Fertility Society and the Association of Clinical Embryologists [J].
Bolton, Virginia N. ;
Leary, Christine ;
Harbottle, Stephen ;
Cutting, Rachel ;
Harper, Joyce C. .
HUMAN FERTILITY, 2015, 18 (03) :156-164
[5]   Conventional and modern markers of endometrial receptivity: a systematic review and meta-analysis [J].
Craciunas, Laurentiu ;
Gallos, Ioannis ;
Chu, Justin ;
Bourne, Tom ;
Quenby, Siobhan ;
Brosens, Jan J. ;
Coomarasamy, Arri .
HUMAN REPRODUCTION UPDATE, 2019, 25 (02) :202-223
[6]   The role of the endometrium and embryo in human implantation [J].
Diedrich, K. ;
Fauser, B. C. J. M. ;
Devroey, P. ;
Griesinger, G. .
HUMAN REPRODUCTION UPDATE, 2007, 13 (04) :365-377
[7]   Evaluation of endometrial receptivity during in-vitro fertilization using three-dimensional power Doppler ultrasound [J].
Järvelä, IY ;
Sladkevicius, P ;
Kelly, S ;
Ojha, K ;
Campbell, S ;
Nargund, G .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 26 (07) :765-769
[8]  
Kupesic S, 2001, J ULTRAS MED, V20, P125
[9]   Endometrial volume and vascularity measurements by transvaginal three-dimensional ultrasonography and power Doppler angiography in stimulated and tumoral endometria:: Intraobserver reproducibility [J].
Mercé, LT ;
Alcázar, JL ;
Engels, V ;
Troyano, J ;
Bau, S ;
Bajo, JM .
GYNECOLOGIC ONCOLOGY, 2006, 100 (03) :544-550
[10]   Are endometrial parameters by three-dimensional ultrasound and power Doppler angiography related to in vitro fertilization/embryo transfer outcome? [J].
Merce, Luis T. ;
Barco, Maria J. ;
Bau, Santiago ;
Troyano, Juan .
FERTILITY AND STERILITY, 2008, 89 (01) :111-117