Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT - a comparison to fixed kV with mAs modulation alone

被引:29
作者
Frellesen, Claudia [1 ]
Stock, Wenzel [1 ]
Kerl, J. Matthias [1 ]
Lehnert, Thomas [1 ]
Wichmann, Julian L. [1 ]
Nau, Christoph [2 ]
Geiger, Emanuel [2 ]
Wutzler, Sebastian [2 ]
Beeres, Martin [1 ]
Schulz, Boris [1 ]
Bodelle, Boris [1 ]
Ackermann, Hanns [3 ]
Vogl, Thomas J. [1 ]
Bauer, Ralf W. [1 ,4 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Clin Goethe Univ, Dept Trauma Hand & Reconstruct Surg, D-60590 Frankfurt, Germany
[3] Clin Goethe Univ, Dept Biostat & Math Modelling, D-60590 Frankfurt, Germany
[4] Klinikum Goethe Univ, Inst Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
Automated tube potential selection; Automated mA modulation; Polytrauma; Thoraco-abdominal CT; Dose reduction; BODY COMPUTED-TOMOGRAPHY; SEVERE BLUNT TRAUMA; IMAGE-QUALITY; RADIATION-EXPOSURE; MULTIPLE TRAUMA; DOSE REDUCTION; ABDOMINAL CT; MANAGEMENT; CANCER; RISKS;
D O I
10.1007/s00330-014-3197-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate the impact of automated attenuation-based tube potential selection on image quality and exposure parameters in polytrauma patients undergoing contrast-enhanced thoraco-abdominal CT. One hundred patients were examined on a 16-slice device at 120 kV with 190 ref.mAs and automated mA modulation only. Another 100 patients underwent 128-slice CT with automated mA modulation and topogram-based automated tube potential selection (autokV) at 100, 120 or 140 kV. Volume CT dose index (CTDIvol), dose-length product (DLP), body diameters, noise, signal-to-noise ratio (SNR) and subjective image quality were compared. In the autokV group, 100 kV was automatically selected in 82 patients, 120 kV in 12 patients and 140 kV in 6 patients. Patient diameters increased with higher kV settings. The median CTDIvol (8.3 vs. 12.4 mGy; -33 %) and DLP (594 vs. 909 mGy cm; -35 %) in the entire autokV group were significantly lower than in the group with fixed 120 kV (p < 0.05 for both). Image quality remained at a constantly high level at any selected kV level. Topogram-based automated selection of the tube potential allows for significant dose savings in thoraco-abdominal trauma CT while image quality remains at a constantly high level. aEuro cent Automated kV selection in thoraco-abdominal trauma CT results in significant dose savings aEuro cent Most patients benefit from a 100-kV protocol with relevant DLP reduction aEuro cent Constantly good image quality is ensured aEuro cent Image quality benefits from higher kV when arms are positioned downward.
引用
收藏
页码:1725 / 1734
页数:10
相关论文
共 26 条
[21]   Cancer Risks After Radiation Exposure in Middle Age [J].
Shuryak, Igor ;
Sachs, Rainer K. ;
Brenner, David J. .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2010, 102 (21) :1628-1636
[22]   The effect of different adaptation strengths on image quality and radiation dose using Siemens Care Dose 4D [J].
Soderberg, Marcus ;
Gunnarsson, Mikael .
RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) :173-179
[23]   Impact on survival of whole-body computed tomography before emergency bleeding control in patients with severe blunt trauma [J].
Wada, Daiki ;
Nakamori, Yasushi ;
Yamakawa, Kazuma ;
Yoshikawa, Yoshiaki ;
Kiguchi, Takeyuki ;
Tasaki, Osamu ;
Ogura, Hiroshi ;
Kuwagata, Yasuyuki ;
Shimazu, Takeshi ;
Hamasaki, Toshimitsu ;
Fujimi, Satoshi .
CRITICAL CARE, 2013, 17 (04)
[24]   Whole-body multislice computed tomography (MSCT) improves trauma care in patients requiring surgery after multiple trauma [J].
Wurmb, T. E. ;
Quaisser, C. ;
Balling, H. ;
Kredel, M. ;
Muellenbach, R. ;
Kenn, W. ;
Roewer, N. ;
Brederlau, J. .
EMERGENCY MEDICINE JOURNAL, 2011, 28 (04) :300-304
[25]   Whole-Body Multislice Computed Tomography as the First Line Diagnostic Tool in Patients With Multiple Injuries: The Focus on Time [J].
Wurmb, Thomas Erik ;
Fruehwald, Peter ;
Hopfner, Witiko ;
Keil, Thorsten ;
Kredel, Markus ;
Brederlau, Joerg ;
Roewer, Norbert ;
Kuhnigk, Herbert .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (03) :658-665
[26]   Impact of whole-body computed tomography on mortality and surgical management of severe blunt trauma [J].
Yeguiayan, Jean-Michel ;
Yap, Anabelle ;
Freysz, Marc ;
Garrigue, Delphine ;
Jacquot, Claude ;
Martin, Claude ;
Binquet, Christine ;
Riou, Bruno ;
Bonithon-Kopp, Claire .
CRITICAL CARE, 2012, 16 (03)