Contrast Imaging in Mouse Embryos Using High-frequency Ultrasound

被引:1
|
作者
Denbeigh, Janet M. [1 ,2 ]
Nixon, Brian A. [1 ,2 ]
Puri, Mira C. [1 ,2 ,3 ]
Foster, F. Stuart [1 ,2 ]
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON M5S 1A1, Canada
[2] Sunnybrook Res Inst, Toronto, ON, Canada
[3] Mt Sinai Hosp, Lunenfeld Tanenbaum Res Inst, Toronto, ON M5G 1X5, Canada
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2015年 / 97期
关键词
Developmental Biology; Issue; 97; Micro-ultrasound; Molecular imaging; Mouse embryo; Microbubble; Ultrasound contrast agent; Perfusion; ENHANCED ULTRASOUND; DEFICIENT MICE; TARGETED MICROBUBBLES; TUMOR ANGIOGENESIS; EXPRESSION; INTEGRIN; ENDOGLIN; SYSTEM; MODEL; US;
D O I
10.3791/52520
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ultrasound contrast-enhanced imaging can convey essential quantitative information regarding tissue vascularity and perfusion and, in targeted applications, facilitate the detection and measure of vascular biomarkers at the molecular level. Within the mouse embryo, this noninvasive technique may be used to uncover basic mechanisms underlying vascular development in the early mouse circulatory system and in genetic models of cardiovascular disease. The mouse embryo also presents as an excellent model for studying the adhesion of microbubbles to angiogenic targets (including vascular endothelial growth factor receptor 2 (VEGFR2) or alpha(v)beta(3)) and for assessing the quantitative nature of molecular ultrasound. We therefore developed a method to introduce ultrasound contrast agents into the vasculature of living, isolated embryos. This allows freedom in terms of injection control and positioning, reproducibility of the imaging plane without obstruction and motion, and simplified image analysis and quantification. Late gestational stage (embryonic day (E) 16.6 and E17.5) murine embryos were isolated from the uterus, gently exteriorized from the yolk sac and microbubble contrast agents were injected into veins accessible on the chorionic surface of the placental disc. Nonlinear contrast ultrasound imaging was then employed to collect a number of basic perfusion parameters (peak enhancement, wash-in rate and time to peak) and quantify targeted microbubble binding in an endoglin mouse model. We show the successful circulation of microbubbles within living embryos and the utility of this approach in characterizing embryonic vasculature and microbubble behavior.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Contrast-enhanced molecular ultrasound differentiates endoglin genotypes in mouse embryos
    Denbeigh, J. M.
    Nixon, B. A.
    Lee, J. J. Y.
    Jerkic, M.
    Marsden, P. A.
    Letarte, M.
    Puri, M. C.
    Foster, F. S.
    ANGIOGENESIS, 2015, 18 (01) : 69 - 81
  • [2] Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and In Vivo Evaluation
    Daeichin, Verya
    van Rooij, Tom
    Skachkov, Ilya
    Ergin, Bulent
    Specht, Patricia A. C.
    Lima, Alexandre
    Ince, Can
    Bosch, Johan G.
    van der Steen, Antonius F. W.
    de Jong, Nico
    Kooiman, Klazina
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (03) : 555 - 567
  • [3] High-frequency Ultrasound Imaging of Mouse Cervical Lymph Nodes
    Walk, Elyse L.
    McLaughlin, Sarah L.
    Weed, Scott A.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (101): : 1 - 9
  • [4] Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound (30/45MHZ) System
    Touma, Marlin
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (135):
  • [5] High-frequency Ultrasound Detection Technique with Contrast Agents
    Wu, Jian-Xing
    Chao, Kuei-Hsiang
    Lai, Hsiang-Yueh
    Liu, Jian-Hung
    Chung, Howard
    Liu, Hsiao-Chuan
    SENSORS AND MATERIALS, 2019, 31 (12) : 4047 - 4059
  • [6] Analysis of Collagen Organization in Mouse Achilles Tendon Using High-Frequency Ultrasound Imaging
    Riggin, Corinne N.
    Sarver, Joseph J.
    Freedman, Benjamin R.
    Thomas, Stephen J.
    Soslowsky, Louis J.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (02):
  • [7] Contrast-enhanced high-frequency ultrasound imaging of early stage liver metastasis in a preclinical mouse model
    Horie, Sachiko
    Chen, Rui
    Li, Li
    Mori, Shiro
    Kodama, Tetsuya
    CANCER LETTERS, 2013, 339 (02) : 208 - 213
  • [8] Contrast-enhanced molecular ultrasound differentiates endoglin genotypes in mouse embryos
    J. M. Denbeigh
    B. A. Nixon
    J. J. Y. Lee
    M. Jerkic
    P. A. Marsden
    M. Letarte
    M. C. Puri
    F. S. Foster
    Angiogenesis, 2015, 18 : 69 - 81
  • [9] Optimization of ultrasound contrast agent for high frequency ultrasound molecular imaging using subharmonic oscillation
    Daeichin, V.
    Kooiman, K.
    Skachkov, I.
    Bosch, J. G.
    van der Steen, A. F. W.
    de Jong, N.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1766 - 1769
  • [10] High-Frequency Nonlinear Doppler Contrast-Enhanced Ultrasound Imaging of Blood Flow
    Bruce, Matthew
    Hannah, Alex
    Hammond, Ryan
    Khaing, Zin Z.
    Tremblay-Darveau, Charles
    Burns, Peter N.
    Hofstetter, Christoph P.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (09) : 1776 - 1784