Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams

被引:220
|
作者
McEwen, Malcolm [1 ]
DeWerd, Larry [2 ]
Ibbott, Geoffrey [3 ]
Followill, David [4 ]
Rogers, David W. O. [5 ]
Seltzer, Stephen [6 ]
Seuntjens, Jan [7 ]
机构
[1] CNR, Ottawa, ON, Canada
[2] Univ Wisconsin, Madison, WI 53705 USA
[3] Univ Texas Houston, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[4] IROC Houston QA Ctr, Radiol Phys Ctr, Houston, TX 77054 USA
[5] Carleton Univ, Dept Phys, Carleton Lab Radiotherapy Phys, Ottawa, ON K1S 5B6, Canada
[6] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
[7] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
关键词
photon beams; dosimetry protocol; ionization chamber; beam quality conversion factors; kQ; uncertainty analysis; absorbed dose calibration coefficients; CYLINDRICAL IONIZATION CHAMBERS; QUALITY CORRECTION FACTORS; ION RECOMBINATION CORRECTIONS; MONTE-CARLO-SIMULATION; ABSORBED-DOSE RATIOS; AIR CAVITY SIZE; EFFECTIVE POINT; ELECTRON DOSIMETRY; AMBIENT-PRESSURE; PLANE-PARALLEL;
D O I
10.1118/1.4866223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An addendum to the AAPM's TG-51 protocol for the determination of absorbed dose to water in megavoltage photon beams is presented. This addendum continues the procedure laid out in TG-51 but new k(Q) data for photon beams, based on Monte Carlo simulations, are presented and recommendations are given to improve the accuracy and consistency of the protocol's implementation. The components of the uncertainty budget in determining absorbed dose to water at the reference point are introduced and the magnitude of each component discussed. Finally, the consistency of experimental determination of N-D,N-w coefficients is discussed. It is expected that the implementation of this addendum will be straightforward, assuming that the user is already familiar with TG-51. The changes introduced by this report are generally minor, although new recommendations could result in procedural changes for individual users. It is expected that the effort on the medical physicist's part to implement this addendum will not be significant and could be done as part of the annual linac calibration. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:20
相关论文
共 14 条
  • [1] AAPM WGTG51 Report 385: Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy electron beams
    Muir, Bryan
    Davis, Stephen
    Dhanesar, Sandeep
    Hillman, Yair
    Iakovenko, Viktor
    Kim, Grace Gwe-Ya
    Alves, Victor Gabriel Leandro
    Lei, Yu
    Lowenstein, Jessica
    Renaud, James
    Sarfehnia, Arman
    Siebers, Jeffrey
    Tantot, Laurent
    MEDICAL PHYSICS, 2024, 51 (09) : 5840 - 5857
  • [2] AAPM WGTG51 Report 374: Guidance for TG-51 reference dosimetry
    Muir, Bryan
    Culberson, Wesley
    Davis, Stephen
    Kim, Grace Gwe-Ya
    Lee, Sung-Woo
    Lowenstein, Jessica
    Renaud, James
    Sarfehnia, Arman
    Siebers, Jeffrey
    Tantot, Laurent
    Tolani, Naresh
    MEDICAL PHYSICS, 2022, 49 (11) : 6739 - 6764
  • [3] Comparison of AAPM Addendum to TG-51, IAEA TRS-398, and JS']JSMP 12: Calibration of photon beams in water
    Kinoshita, Naoki
    Oguchi, Hiroshi
    Nishimoto, Yasuhiro
    Adachi, Toshiki
    Shioura, Hiroki
    Kimura, Hirohiko
    Doi, Kunio
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 271 - 278
  • [4] TG-51 reference dosimetry for the Halcyon™: A clinical experience
    Lloyd, Samantha A. M.
    Lim, Tze Yee
    Fave, Xenia
    Flores-Martinez, Everardo
    Atwood, Todd F.
    Moiseenko, Vitali
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 98 - 102
  • [5] Effect of ICRU report 90 recommendations on Monte Carlo calculated kQ for ionization chambers listed in the Addendum to AAPM's TG-51 protocol
    Kawachi, Toru
    Saitoh, Hidetoshi
    Katayose, Tetsurou
    Tohyama, Naoki
    Miyasaka, Ryohei
    Cho, Sang Yong
    Iwase, Tsutomu
    Hara, Ryusuke
    MEDICAL PHYSICS, 2019, 46 (11) : 5185 - 5194
  • [6] Technical note: Consistency of IAEA's TRS-483 and AAPM's extended TG-51 protocols for clinical reference dosimetry of the CyberKnife M6 machine
    Duchaine, Jasmine
    Markel, Daniel
    Ley, Jean-Luc
    Beliveau-Nadeau, Dominique
    Zerouali, Karim
    Doucet, Robert
    Bouchard, Hugo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (05):
  • [7] Reference dosimetry for MRI-Linacs: an addendum to the 2020 IPEM code of practice for high-energy photon therapy dosimetry
    Billas, Ilias
    Budgell, Geoff
    George, Ben
    Thomas, Russell A. S.
    Duane, Simon
    Eaton, David J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (08)
  • [8] CALIBRATION OF HIGH-ENERGY PHOTON AND ELECTRON-BEAMS FOR RADIOTHERAPY USING AAPM-1983 AND IAEA-1987 DOSIMETRY PROTOCOLS
    HUQ, MS
    AGOSTINELLI, AG
    NATH, R
    MEDICAL PHYSICS, 1993, 20 (02) : 293 - 298
  • [9] COMPARISON OF FERROUS SULFATE (FRICKE) AND IONIZATION DOSIMETRY FOR HIGH-ENERGY PHOTON AND ELECTRON-BEAMS
    KWA, W
    KORNELSEN, RO
    MEDICAL PHYSICS, 1990, 17 (04) : 602 - 606
  • [10] Experimental study of humidity effect on charge measurement of reference ionization chambers in clinical high-energy photon beams
    Sato, Yuuki
    Shimizu, Morihito
    Morishita, Yuichiro
    Sato, Masanori
    Hoshina, Masao
    MEDICAL PHYSICS, 2019, 46 (09) : 4177 - 4183