Fabrication of Nickel/nanodiamond/boron-doped diamond electrode for non-enzymatic glucose biosensor

被引:46
|
作者
Dai, Wei [1 ]
Li, Mingji [2 ]
Gao, Sumei [3 ]
Li, Hongji [4 ]
Li, Cuiping [2 ]
Xu, Sheng [1 ]
Wu, Xiaoguo [2 ]
Yang, Baohe [1 ,2 ]
机构
[1] Tianjin Univ, Sch Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Tianjin Univ Technol, Sch Elect Informat Engn, Tianjin Key Lab Film Elect & Communicate Devices, Tianjin 300384, Peoples R China
[3] Tianjin Vocat Inst, Sch Elect & Informat Engn, Tianjin 300410, Peoples R China
[4] Tianjin Univ Technol, Sch Chem & Chem Engn, Tianjin Key Lab Organ Solar Cells & Photochem Con, Tianjin 300384, Peoples R China
关键词
Nickel nanosheet; Nanodiamond; Boron-doped diamond; Non-enzymatic biosensor; Glucose; REDUCED GRAPHENE OXIDE; GLASSY-CARBON ELECTRODE; NICKEL-OXIDE; NANOPARTICLES; SENSOR; NANOWIRES; DEPOSITION; FILM; COMPOSITES; NANOFIBERS;
D O I
10.1016/j.electacta.2015.11.085
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A stable and sensitive non-enzymatic glucose sensor was prepared by modifying a boron-doped diamond (BDD) electrode with nickel (Ni) nanosheets and nanodiamonds (NDs). The NDs were electrophoretically deposited on the BDD surface, and acted as nucleation sites for the subsequent electrodeposition of Ni. The morphology and composition of the modified BDD electrodes were characterized by field-emission scanning electron microscopy and energy-dispersive X-ray spectroscopy, respectively. The Ni nanosheet-ND modified BDD electrode exhibited good current response towards the non-enzymatic oxidation of glucose in alkaline media. The NDs significantly extended the potential window. The response to glucose was linear over the 0.2-1055.4-mu M range. The limit of detection was 0.05 mu M, at a signal-to-noise ratio of 3. The Ni nanosheet-ND/BDD electrode exhibited good selectivity, reproducibility and stability. Its electrochemical performance, low cost and simple preparation make it a promising non-enzymatic glucose sensor. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:413 / 421
页数:9
相关论文
共 50 条
  • [21] Application of unmodified boron-doped diamond electrode for determination of dopamine and paracetamol
    Tyszczuk-Rotko, Katarzyna
    Jaworska, Izabela
    Jedruchniewicz, Katarzyna
    MICROCHEMICAL JOURNAL, 2019, 146 : 664 - 672
  • [22] Highly sensitive non-enzymatic lactate biosensor driven by porous nanostructured nickel oxide
    Kim, Sungjin
    Yang, Won Sik
    Kim, Hyun-Jong
    Lee, Ho-Nyun
    Park, Tae Joo
    Seo, Seok-Jun
    Park, Young Min
    CERAMICS INTERNATIONAL, 2019, 45 (17) : 23370 - 23376
  • [23] An Electrochemical Sensor of Theophylline on a Boron-Doped Diamond Electrode Modified with Nickel Nanoparticles
    Jiwanti, Prastika Krisma
    Sari, Anis Puspita
    Wafiroh, Siti
    Hartati, Yeni Wahyuni
    Gunlazuardi, Jarnuzi
    Putri, Yulia M. T. A.
    Kondo, Takeshi
    Anjani, Qonita Kurnia
    SENSORS, 2023, 23 (20)
  • [24] Electrochemical Sensor of Levofloxacin on Boron-Doped Diamond Electrode Decorated by Nickel Nanoparticles
    Jiwanti, Prastika Krisma
    Sitorus, Irfansyah Rais
    Kadja, Grandprix Thomryes Mart
    Wafiroh, Siti
    Einaga, Yasuaki
    INDONESIAN JOURNAL OF CHEMISTRY, 2022, 22 (05) : 1321 - 1329
  • [25] New CuO nanocomposite as non-enzymatic glucose biosensor
    Ghorbani, Mojtaba
    Tarlani, Aliakbar
    Taghvaei-Ganjali, Saeed
    Malekzade, Mercede
    NANOMEDICINE JOURNAL, 2025, 12 (02) : 252 - 261
  • [26] Electrochemical Imprinted Polycrystalline Nickel-Nickel Oxide Half-Nanotube-Modified Boron-Doped Diamond Electrode for the Detection of L-Serine
    Dai, Wei
    Li, Hongji
    Li, Mingji
    Li, Cuiping
    Wu, Xiaoguo
    Yang, Baohe
    ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (41) : 22858 - 22867
  • [27] Development of an amperometric biosensor based on covalent immobilization of tyrosinase on a boron-doped diamond electrode
    Zhou, YanLi
    Zhi, JinFang
    ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (12) : 1811 - 1816
  • [28] Pt-polyaniline nanocomposite on boron-doped diamond electrode for amperometic biosensor with low detection limit
    Song, Min-Jung
    Kim, Jong Hoon
    Lee, Seung Koo
    Lee, Jae-Hyun
    Lim, Dae Soon
    Hwang, Sung Woo
    Whang, Dongmok
    MICROCHIMICA ACTA, 2010, 171 (3-4) : 249 - 255
  • [29] Non-enzymatic glucose biosensor based on hyperbranched pine-like gold nanostructure
    Heli, H.
    Amirizadeh, O.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 63 : 150 - 154
  • [30] Simple fabrication of ZnO/Pt/chitosan electrode for enzymatic glucose biosensor
    Anusha, J. R.
    Kim, Hee-Je
    Fleming, Albin T.
    Das, S. Jerome
    Yu, Kook-Hyun
    Kim, Byung Chul
    Raj, C. Justin
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 : 827 - 833