The diagnosis of renovascular hypertension with technetium-99m-ethylenedicysteine captopril scintigraphy

被引:0
|
作者
Ugur, O [1 ]
Caner, B [1 ]
Cekirge, S [1 ]
Balkanci, F [1 ]
Ergun, EL [1 ]
Kostakoglu, L [1 ]
Bekdik, C [1 ]
机构
[1] HACETTEPE UNIV,FAC MED,DEPT RADIOL,TR-06100 ANKARA,TURKEY
关键词
renovascular hypertension; renal artery stenosis; captopril renal scintigraphy; technetium-99m-ethylenedicysteine; renal imaging;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors present preliminary findings on the diagnosis of renovascular hypertension with technetium-99m-ethylenedicysteine (Tc-99m-EC). METHODS. Thirty-nine patients referred to the nuclear medicine department with clinical evidence of renovascular hypertension were included in the study, Baseline and captopril scintigraphies were done on separate days after the injection of 185 MBq of Tc-99m-EC. All patients had angiographic correlation and 9 patients were shown to have renal artery stenosis, RESULTS. Quantitative analysis of the data showed no significant changes of perfusion index (PI), split renal function (SRF), and effective renal plasma flow (ERPF) values between pre- and postcaptopril studies in patients with significant renal artery stenosis (P > 0.05), Baseline and postcaptopril values for PI, SRF, and ERPF were measured as 128 +/- 21 and 116 +/- 12 mL/minute, 47 +/- 1 and 50 +/- 2 mL/minute, and 250 +/- 18 and 231 +/- 20 mL/minute, respectively. However, time to maximum activity (T-max), time to half maximum activity (T-1/2), time to two thirds of maximum activity (T-2/3), and residual cortical activity (RCA) values showed marked changes with a rising renogram curve (P < 0.05), Baseline and postcaptopril values for T-max, T-1/2, T-2/3, and RCA were measured as 3.1 +/- 0.1 and 20.2 +/- 1 minute, 5.4 +/- 0.4 and 45.4 +/- 3.1 minutes, 3.1 +/- 0.2 and 33.7 +/- 4.1 minutes, and 27 +/- 4 and 215 +/- 34 minutes, respectively. All scintigraphic studies showed good correlation with angiography and no false-positive or false-negative results were observed, CONCLUSIONS. This preliminary study demonstrates that Tc-99m-EC has good potential for the diagnosis of renovascular hypertension and that a single diagnostic criteria, specifically a rising renogram curve, seems adequate, However, the authors' initial results should be confirmed in a broader patient population.
引用
收藏
页码:497 / 501
页数:5
相关论文
共 50 条
  • [21] Reproducibility of technetium-99m ethylenedicysteine clearance
    Levent Kabasakal
    Metin Halaç
    Ebru Alkan
    Nihat Özçelik
    I. lhami Uslu
    European Journal of Nuclear Medicine, 1999, 26 : 900 - 902
  • [22] Reproducibility of technetium-99m ethylenedicysteine clearance
    Cerrahpaşa Medical Faculty, Department of Nuclear Medicine, Istanbul, Turkey
    不详
    Eur. J. Nucl. Med. Mol. Imaging, 8 (900-902):
  • [23] Captopril renal scintigraphy and duplex Doppler sonography in diagnosis of renovascular hypertension.
    Lantsberg, S
    Rachinsky, I
    Klimov, A
    Szendro, G
    Boguslavsky, L
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1122 - 1122
  • [24] THE ROLE OF CAPTOPRIL SCINTIGRAPHY IN THE DIAGNOSIS AND MANAGEMENT OF RENOVASCULAR HYPERTENSION - A CONSENSUS CONFERENCE - INTRODUCTION
    BLACK, HR
    NALLY, JV
    AMERICAN JOURNAL OF HYPERTENSION, 1991, 4 (12) : S661 - S662
  • [25] THE DIAGNOSIS OF RENOVASCULAR HYPERTENSION - THE ROLE OF CAPTOPRIL RENAL SCINTIGRAPHY AND RELATED ISSUES - REPLY
    PRIGENT, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (03): : 265 - 267
  • [26] CAPTOPRIL-ENHANCED (99)TC(M)-MAG3 RENAL SCINTIGRAPHY IN SUBJECTS WITH SUSPECTED RENOVASCULAR HYPERTENSION
    KAHN, D
    BENHAIM, S
    BUSHNELL, DL
    MADSEN, MT
    KIRCHNER, PT
    NUCLEAR MEDICINE COMMUNICATIONS, 1994, 15 (07) : 515 - 528
  • [27] Diagnosis of renovascular hypertension: Feasibility of captopril-sensitized dynamic MR imaging and comparison with captopril scintigraphy
    Grenier, N
    Trillaud, H
    Combe, C
    Degreze, P
    Jeandot, R
    Gosse, P
    Douws, C
    Palussiere, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) : 835 - 843
  • [28] CAPTOPRIL RENOGRAPHY IN THE DIAGNOSIS OF RENOVASCULAR HYPERTENSION
    LEE, KJ
    ROSSLEIGH, MA
    FULTON, RR
    HORVATH, JS
    MORRIS, JG
    WAUGH, R
    MAY, J
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1988, 18 (03): : 513 - 513
  • [29] Prediction of response to revascularization in patients with renal artery stenosis by Tc-99m-ethylenedicysteine captopril scintigraphy
    Uǧur Ö.
    Serdengeçti M.
    Karacalioǧlu Ö.
    Ergün E.L.
    Peksoy I.
    Çekirge S.
    Annals of Nuclear Medicine, 1999, 13 (2) : 77 - 81
  • [30] PROGNOSTIC VALUE OF CAPTOPRIL RENAL SCINTIGRAPHY IN RENOVASCULAR HYPERTENSION
    DONDI, M
    FANTI, S
    DEFABRITIIS, A
    ZUCCALA, A
    GAGGI, R
    MIRELLI, M
    STELLA, A
    MARENGO, M
    LOSINNO, F
    MONETTI, N
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (11) : 2040 - 2044