The diagnosis of renovascular hypertension with technetium-99m-ethylenedicysteine captopril scintigraphy

被引:0
|
作者
Ugur, O [1 ]
Caner, B [1 ]
Cekirge, S [1 ]
Balkanci, F [1 ]
Ergun, EL [1 ]
Kostakoglu, L [1 ]
Bekdik, C [1 ]
机构
[1] HACETTEPE UNIV,FAC MED,DEPT RADIOL,TR-06100 ANKARA,TURKEY
关键词
renovascular hypertension; renal artery stenosis; captopril renal scintigraphy; technetium-99m-ethylenedicysteine; renal imaging;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors present preliminary findings on the diagnosis of renovascular hypertension with technetium-99m-ethylenedicysteine (Tc-99m-EC). METHODS. Thirty-nine patients referred to the nuclear medicine department with clinical evidence of renovascular hypertension were included in the study, Baseline and captopril scintigraphies were done on separate days after the injection of 185 MBq of Tc-99m-EC. All patients had angiographic correlation and 9 patients were shown to have renal artery stenosis, RESULTS. Quantitative analysis of the data showed no significant changes of perfusion index (PI), split renal function (SRF), and effective renal plasma flow (ERPF) values between pre- and postcaptopril studies in patients with significant renal artery stenosis (P > 0.05), Baseline and postcaptopril values for PI, SRF, and ERPF were measured as 128 +/- 21 and 116 +/- 12 mL/minute, 47 +/- 1 and 50 +/- 2 mL/minute, and 250 +/- 18 and 231 +/- 20 mL/minute, respectively. However, time to maximum activity (T-max), time to half maximum activity (T-1/2), time to two thirds of maximum activity (T-2/3), and residual cortical activity (RCA) values showed marked changes with a rising renogram curve (P < 0.05), Baseline and postcaptopril values for T-max, T-1/2, T-2/3, and RCA were measured as 3.1 +/- 0.1 and 20.2 +/- 1 minute, 5.4 +/- 0.4 and 45.4 +/- 3.1 minutes, 3.1 +/- 0.2 and 33.7 +/- 4.1 minutes, and 27 +/- 4 and 215 +/- 34 minutes, respectively. All scintigraphic studies showed good correlation with angiography and no false-positive or false-negative results were observed, CONCLUSIONS. This preliminary study demonstrates that Tc-99m-EC has good potential for the diagnosis of renovascular hypertension and that a single diagnostic criteria, specifically a rising renogram curve, seems adequate, However, the authors' initial results should be confirmed in a broader patient population.
引用
收藏
页码:497 / 501
页数:5
相关论文
共 26 条
  • [1] Technetium-99m-ethylenedicysteine in the diagnosis and follow-up of renovascular hypertension
    Ugur, O
    Caner, B
    Cekirge, S
    Balkanci, F
    Ergun, EL
    Kostakoglu, L
    Aras, T
    Bekdik, C
    INVESTIGATIVE RADIOLOGY, 1996, 31 (06) : 378 - 381
  • [2] TC-99M-MAG3 RENAL-FUNCTION SCINTIGRAPHY AND CAPTOPRIL IN THE DIAGNOSIS OF RENOVASCULAR HYPERTENSION
    PIEPENBURG, R
    BOCKISCH, A
    ANDREAS, J
    DUBER, C
    KANN, P
    MAIER, G
    HAHN, K
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 159 (02): : 150 - 157
  • [3] THE DIAGNOSIS OF RENOVASCULAR HYPERTENSION - THE ROLE OF CAPTOPRIL RENAL SCINTIGRAPHY AND RELATED ISSUES
    PRIGENT, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1993, 20 (07): : 625 - 644
  • [4] Prediction of response to revascularization in patients with renal artery stenosis by Tc-99m-ethylenedicysteine captopril scintigraphy
    Uǧur Ö.
    Serdengeçti M.
    Karacalioǧlu Ö.
    Ergün E.L.
    Peksoy I.
    Çekirge S.
    Annals of Nuclear Medicine, 1999, 13 (2) : 77 - 81
  • [5] Prediction of response to revascularization in patients with renal artery stenosis by Tc-99m-ethylenedicysteine captopril scintigraphy
    Ugur, Ö
    Serdengeçti, M
    Karacalioglu, Ö
    Ergün, EL
    Peksoy, I
    Çekirge, S
    ANNALS OF NUCLEAR MEDICINE, 1999, 13 (02) : 77 - 81
  • [6] LIMITATIONS OF THE CAPTOPRIL TEST IN THE DIAGNOSIS OF RENOVASCULAR HYPERTENSION
    ZAHGER, D
    KOBRIN, I
    YESHURUN, D
    BENISHAY, D
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1991, 27 (02): : 67 - 69
  • [7] Free technetium: Potential pitfall in the diagnosis of renovascular hypertension
    Hunsche, A
    Grossman, GB
    Galt, JR
    Halkar, RK
    CLINICAL NUCLEAR MEDICINE, 2004, 29 (03) : 218 - 221
  • [8] EVALUATION OF CAPTOPRIL RENOGRAPHY WITH99mTc-MAG3 IN THE DIAGNOSIS OF RENOVASCULAR HYPERTENSION
    康增寿
    陈方
    王志强
    Chinese Medical Sciences Journal, 1994, (01)
  • [9] Role of captopril renography in the diagnosis of renovascular hypertension
    Mittal, BR
    Kumar, P
    Arora, P
    Kher, V
    Singhal, MK
    Maini, A
    Das, BK
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1996, 28 (02) : 209 - 213
  • [10] Captopril renography and duplex Doppler sonography in the diagnosis of renovascular hypertension
    Kaplan-Pavlovcic, S
    Nadja, C
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (02) : 313 - 317