Copper hexacyanoferrate modified electrodes for hydrogen peroxide detection as studied by X-ray absorption spectroscopy

被引:17
作者
Giorgetti, Marco [1 ]
Tonelli, Domenica [1 ]
Berrettoni, Mario [2 ]
Aquilanti, Giuliana [3 ]
Minicucci, Marco [4 ]
机构
[1] Univ Bologna, INSTM, Dept Ind Chem Toso Montanari, UdR Bologna, I-40136 Bologna, Italy
[2] Univ Bologna, INSTM, UOs Unita Operat Sede, Dept Ind Chem Toso Montanari, I-40136 Bologna, Italy
[3] Sincrotrone Trieste SCpA, I-34149 Trieste, Italy
[4] Univ Camerino, Sch Sci & Technol, Div Phys, CNISM, I-62032 Camerino, MC, Italy
关键词
X-ray absorption spectroscopy; Hydrogen peroxide; Copper hexacyanoferrate; Graphite foil electrodes; Sensor; BODY DISTRIBUTION-FUNCTIONS; PRUSSIAN BLUE; CONDENSED MATTER; SOLID-STATE; IRON; ELECTROCHEMISTRY; IDENTITY;
D O I
10.1007/s10008-013-2343-5
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
X-ray absorption spectroscopy (XAS) has been used to monitor the local geometry of Fe and Cu sites of copper hexacyanoferrates (CuHCF)-modified electrodes which find application in the electrochemical detection of hydrogen peroxide. The XAS approach has permitted to check the nature of the Cu and Fe sites and to investigate their local structure around about 500 pm from the metal centres. The measurements have been done on electrodes prior and after the addition of known quantities of hydrogen peroxide at two different concentration ranges, following a protocol consisting of H2O2 addition, applied potential, and rest period. For the CuHCF-modified electrode, this protocol leads to the increasing conversion to an already present "inactive" component, which limits the usability of the sensor; whereas the electrode modified with the Cu2+-loaded CuHCF displays a better resistance to this unavoidable process. In particular, the formation of the "inactive" component takes place more slowly, confirming the capability, at molecular scale, of such Cu-enriched CuHCF used as electrode modifier to detect more efficiently hydrogen peroxide, as recently demonstrated in our previous paper.
引用
收藏
页码:965 / 973
页数:9
相关论文
共 40 条
  • [1] Porous framework of T2[Fe(CN)6]•xH2O with T = Co, Ni, Cu, Zn, and H2 storage
    Avila, M.
    Reguera, L.
    Rodriguez-Hernandez, J.
    Balmaseda, J.
    Reguera, E.
    [J]. JOURNAL OF SOLID STATE CHEMISTRY, 2008, 181 (11) : 2899 - 2907
  • [2] Synthesis and Characterization of Nanostructured Cobalt Hexacyanoferrate
    Berrettoni, Mario
    Giorgetti, Marco
    Zamponi, Silvia
    Conti, Paolo
    Ranganathan, David
    Zanotto, Antonio
    Saladino, Maria Luisa
    Caponetti, Eugenio
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (14) : 6401 - 6407
  • [3] Chen L, 2012, J MATER CHEM, V22, P22090, DOI [10.1039/c2jm34541, 10.1039/c2jm34541b]
  • [4] Metal hexacyanoferrates: Electrosynthesis, in situ characterization, and applications
    de Tacconi, NR
    Rajeshwar, K
    Lezna, RO
    [J]. CHEMISTRY OF MATERIALS, 2003, 15 (16) : 3046 - 3062
  • [5] Novel XAFS capabilities at ELETTRA synchrotron light source
    Di Cicco, Andrea
    Aquilanti, Giuliana
    Minicucci, Marco
    Principi, Emiliano
    Novello, Nicola
    Cognigni, Andrea
    Olivi, Luca
    [J]. 14TH INTERNATIONAL CONFERENCE ON X-RAY ABSORPTION FINE STRUCTURE (XAFS14), PROCEEDINGS, 2009, 190
  • [6] Straightforward Synthesis of Gold Nanoparticles Supported on Commercial Silica-Polyethyleneimine Beads
    Fazzini, Silvia
    Nanni, Daniele
    Ballarin, Barbara
    Cassani, Maria Cristina
    Giorgetti, Marco
    Maccato, Chiara
    Trapananti, Angela
    Aquilanti, Giuliana
    Ahmed, Sameh Ibrahim
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2012, 116 (48) : 25434 - 25443
  • [7] X-ray-absorption spectroscopy and n-body distribution functions in condensed matter .2. Data analysis and applications
    Filipponi, A
    DiCicco, A
    [J]. PHYSICAL REVIEW B, 1995, 52 (21): : 15135 - 15149
  • [8] X-ray-absorption spectroscopy and n-body distribution functions in condensed matter .1. Theory
    Filipponi, A
    DiCicco, A
    Natoli, CR
    [J]. PHYSICAL REVIEW B, 1995, 52 (21): : 15122 - 15134
  • [9] STATISTICAL ERRORS IN X-RAY-ABSORPTION FINE-STRUCTURE DATA-ANALYSIS
    FILIPPONI, A
    [J]. JOURNAL OF PHYSICS-CONDENSED MATTER, 1995, 7 (48) : 9343 - 9356
  • [10] The X-ray Absorption Spectroscopic Model of the Copper(II) Imidazole Complex Ion in Liquid Aqueous Solution: A Strongly Solvated Square Pyramid
    Frank, Patrick
    Benfatto, Maurizio
    Hedman, Britt
    Hodgson, Keith O.
    [J]. INORGANIC CHEMISTRY, 2012, 51 (04) : 2086 - 2096