Ex-vivo machine perfusion for kidney preservation

被引:42
作者
Hamar, Matyas [1 ]
Selzner, Markus [1 ]
机构
[1] Toronto Gen Hosp, Multi Organ Transplant Program, Dept Surg, 11 PMB 178,585 Univ Ave, Toronto, ON M5G 2N2, Canada
关键词
hypothermic; kidney transplantation; machine perfusion; normothermic; preservation; ISCHEMIA-REPERFUSION INJURY; DECLINED HUMAN KIDNEYS; STATIC COLD-STORAGE; NORMOTHERMIC PERFUSION; CARDIAC DEATH; PORCINE KIDNEYS; RENAL-TRANSPLANTATION; QUALITY ASSESSMENT; DONATION; DONORS;
D O I
10.1097/MOT.0000000000000524
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Purpose of reviewMachine perfusion is a novel strategy to decrease preservation injury, improve graft assessment, and increase organ acceptance for transplantation. This review summarizes the current advances in ex-vivo machine-based kidney preservation technologies over the last year.Recent findingsEx-vivo perfusion technologies, such as hypothermic and normothermic machine perfusion and controlled oxygenated rewarming, have gained high interest in the field of organ preservation. Keeping kidney grafts functionally and metabolically active during the preservation period offers a unique chance for viability assessment, reconditioning, and organ repair. Normothermic ex-vivo kidney perfusion has been recently translated into clinical practice. Preclinical results suggest that prolonged warm perfusion appears superior than a brief end-ischemic reconditioning in terms of renal function and injury. An established standardized protocol for continuous warm perfusion is still not available for human grafts.SummaryEx-vivo machine perfusion represents a superior organ preservation method over static cold storage. There is still an urgent need for the optimization of the perfusion fluid and machine technology and to identify the optimal indication in kidney transplantation. Recent research is focusing on graft assessment and therapeutic strategies.
引用
收藏
页码:369 / 374
页数:6
相关论文
共 43 条
[1]  
Adams TD, 2017, TRANSPLANT DIRECT, V3, DOI 10.1097/TXD.0000000000000655
[2]   Comparison of normothermic and hypothermic perfusion in porcine kidneys donated after cardiac death [J].
Blum, Matthew F. ;
Liu, Qiang ;
Soliman, Basem ;
Dreher, Paul ;
Okamoto, Toshihiro ;
Poggio, Emilio D. ;
Goldfarb, David A. ;
Baldwin, William M., III ;
Quintini, Cristiano .
JOURNAL OF SURGICAL RESEARCH, 2017, 216 :35-45
[3]   Evaluation of quality of kidneys from donation after circulatory death/expanded criteria donors by parameters of machine perfusion [J].
Chen, Guodong ;
Wang, Chang ;
Zhao, Yi ;
Qiu, Longhui ;
Yuan, Xiaopeng ;
Qiu, Jiang ;
Wang, Changxi ;
He, Xiaoshun ;
Chen, Lizhong .
NEPHROLOGY, 2018, 23 (02) :103-106
[4]   The effect of the use of a TNF-alpha inhibitor in hypothermic machine perfusion on kidney function after transplantation [J].
Diuwe, Piotr ;
Domagala, Piotr ;
Durlik, Magdalena ;
Trzebicki, Janusz ;
Chmura, Andrzej ;
Kwiatkowski, Artur .
CONTEMPORARY CLINICAL TRIALS, 2017, 59 :44-50
[5]   Reconditioning by end-ischemic hypothermic in-house machine perfusion: A promising strategy to improve outcome in expanded criteria donors kidney transplantation [J].
Gallinat, Anja ;
Amrillaeva, Vera ;
Hoyer, Dieter P. ;
Kocabayoglu, Peri ;
Benko, Tamas ;
Treckmann, Juergen W. ;
van Meel, Marieke ;
Samuel, Undine ;
Minor, Thomas ;
Paul, Andreas .
CLINICAL TRANSPLANTATION, 2017, 31 (03)
[6]   Perfusion of isolated rat kidney with Mesenchymal Stromal Cells/Extracellular Vesicles prevents ischaemic injury [J].
Gregorini, Marilena ;
Corradetti, Valeria ;
Pattonieri, Eleonora Francesca ;
Rocca, Chiara ;
Milanesi, Samantha ;
Peloso, Andrea ;
Canevari, Silvana ;
De Cecco, Loris ;
Dugo, Matteo ;
Avanzini, Maria Antonietta ;
Mantelli, Melissa ;
Maestri, Marcello ;
Esposito, Pasquale ;
Bruno, Stefania ;
Libetta, Carmelo ;
Dal Canton, Antonio ;
Rampino, Teresa .
JOURNAL OF CELLULAR AND MOLECULAR MEDICINE, 2017, 21 (12) :3381-3393
[7]   An ex vivo comparison of adenosine and lidocaine solution and University of Wisconsin solution for hypothermic machine perfusion of porcine kidneys: potential for development [J].
Hamaoui, Karim ;
Aftab, Adeel ;
Gowers, Sally ;
Boutelle, Martyn ;
Cook, Terry ;
Rudd, Donna ;
Dobson, Geoffrey P. ;
Papalois, Vassilios .
JOURNAL OF SURGICAL RESEARCH, 2017, 208 :219-229
[8]   Organ Pretreatment With Cytotopic Endothelial Localizing Peptides to Ameliorate Microvascular Thrombosis and Perfusion Deficits in Ex Vivo Renal Hemoreperfusion Models [J].
Hamaoui, Karim ;
Gowers, Sally ;
Boutelle, Martyn ;
Cook, Terry H. ;
Hanna, George ;
Darzi, Ara ;
Smith, Richard ;
Dorling, Anthony ;
Papalois, Vassilios .
TRANSPLANTATION, 2016, 100 (12) :E128-E139
[9]   Maximizing kidneys for transplantation using machine perfusion: from the past to the future: A comprehensive systematic review and meta-analysis [J].
Hameed, Ahmer M. ;
Pleass, Henry C. ;
Wong, Germaine ;
Hawthorne, Wayne J. .
MEDICINE, 2016, 95 (40)
[10]   Hypothermic Machine Perfusion's Protection on Porcine Kidney Graft Uncovers Greater Akt-Erk Phosphorylation [J].
He, N. ;
Li, J. -H. ;
Jia, J. -J. ;
Xu, K. -D. ;
Zhou, Y. -F. ;
Jiang, L. ;
Lu, H. -H. ;
Yin, S. -Y. ;
Xie, H. -Y. ;
Zhou, L. ;
Zheng, S. -S. .
TRANSPLANTATION PROCEEDINGS, 2017, 49 (08) :1923-1929