Comparison of Circular and Polygonal Planar Orbits for Pinhole and Slit-Slat SPECT

被引:1
作者
Accorsi, Roberto [1 ]
Ayan, Ahmet S. [2 ]
Metzler, Scott D. [2 ]
机构
[1] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
Gamma-ray cameras; medical imaging; SPECT; IMAGE-RECONSTRUCTION; RESOLUTION; SENSITIVITY; LINOGRAMS; IMPLEMENTATION; PROJECTIONS; COLLIMATION; ACQUISITION; ANGLE;
D O I
10.1109/TNS.2009.2013465
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Analytic formulas and Monte Carlo simulation are used to calculate and compare the sensitivity of circular and polygonal orbits at different points in the Field of View (FoV) for both pinhole and slit-slat collimation. Results show that for a given slit-slat collimator an N-sided polygonal orbit tangent to the FoV generally provides average sensitivity lower than the tightest circular orbit consistent with the same aperture angle, but with better spatial resolution that can be traded for sensitivity for a constant-resolution comparison. This generally results in a slight advantage for the polygonal orbit. However, this advantage depends on the clearance that must be allowed between the orbit and the FoV and decreases quickly, vanishing when even a few millimeters of space are left, which in practice is necessary to accommodate mechanical constraints. For a pinhole collimator the advantage for the tangent polygonal orbit is more consistent, but similar conclusions are reached again when clearance is considered. A direct comparison at constant resolution between slit-slat and pinhole collimation in a single transverse plane is shown to be possible with parameters typical of small-animal imaging applications only for detectors with excellent intrinsic resolution; in this case, pinhole collimation is shown to be more sensitive in magnifying geometries, but reduced axial FoV and increased axial blurring should also be considered for a more complete comparison.
引用
收藏
页码:694 / 703
页数:10
相关论文
共 13 条
[1]   Resolution-effective diameters for asymmetric-knife-edge pinhole collimators [J].
Accorsi, R ;
Metzler, SD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (12) :1637-1646
[2]   Derivation and validation of a sensitivity formula for slit-slat collimation [J].
Accorsi, Roberto ;
Novak, John R. ;
Ayan, Ahmet S. ;
Metzler, Scott D. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (05) :709-722
[3]  
Anger H.O., 1967, INSTRUMENTATION NUCL, V1, P485
[4]   IMAGE-RECONSTRUCTION FROM LINOGRAMS - IMPLEMENTATION AND EVALUATION [J].
EDHOLM, P ;
HERMAN, GT ;
ROBERTS, DA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (03) :239-246
[5]   LINOGRAMS IN IMAGE-RECONSTRUCTION FROM PROJECTIONS [J].
EDHOLM, PR ;
HERMAN, GT .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (04) :301-307
[6]   SOLID ANGLE SUBTENDED BY A RECTANGULAR SLIT [J].
GOTOH, H ;
YAGI, H .
NUCLEAR INSTRUMENTS & METHODS, 1971, 96 (03) :485-&
[7]  
Metzler SD, 2006, J NUCL MED, V47, P1884
[8]   Verification of the sensitivity and resolution dependence on the incidence angle for slit-slat collimation [J].
Novak, J. R. ;
Ayan, A. S. ;
Accorsi, R. ;
Metzler, S. D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (04) :953-966
[9]  
Orlov S. S., 1976, Soviet Physics - Crystallography, V20, P312
[10]  
Rogers W L, 1982, IEEE Trans Med Imaging, V1, P63, DOI 10.1109/TMI.1982.4307549