Simultaneous quantitative determination of zidovudine and nevirapine in human plasma using isocratic, reverse phase high performance liquid chromatography

被引:0
|
作者
Kabra, Vibhuti [1 ]
Agrahari, Vivek [1 ]
Karthikeyan, Chandrabose [2 ]
Trivedi, Piyush [2 ]
机构
[1] Shri GS Inst Technol & Sci, Dept Pharm, Indore 452001, Madhya Pradesh, India
[2] Rajiv Gandhi Tech Univ, Sch Pharmaceut Sci, Bhopal 462036, Madhya Pradesh, India
关键词
Assay; Zidovudine; Nevirapine; Human plasma; Reverse phase high-performance liquid chromatography; SIMULTANEOUS QUANTIFICATION; ANTIRETROVIRAL THERAPY; RAPID-DETERMINATION; URINE; SERUM; METABOLITES; GLUCURONIDE; INFECTION; AGENTS;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose: To develop a sensitive and rapid reverse phase high performance liquid chromatography (HPLC) method for the measurement of the levels of zidovudine (ZVD) and nevirapine (NVP) in human plasma. Methods: Standard stock solutions for HPLC analysis were prepared by dissolving ZVD and NVP in methanol. In the HPLC measurement, sample detection was carried out at 246 nm using an ultraviolet (UV)-photo diode array (PDA) detector. Plasma sample pretreatment consisted of protein precipitation extraction with methanol. The compounds were separated using a mobile phase consisting of a pH 3.0 solution (obtained by adjusting the pH of water with orthophosphoric acid): acetonitrile (73:27 v/v) on a Phenomenex LUNA C(18), column (250x4.6 mm i.d., 5 mu m) at a flow rate of 0.9 mL min(-1). The total run time for the assay was 10.2 min. The method was validated over the range of 300-9600 ng mL(-1) and 200-6400 ng mL(-1) for ZVD and NVP, respectively. Results: The lowest limits of quantification (LLOQ) and of detection (LOD) were 300 and 63 ng mL(-1) for ZVD and 200 and 17 ng mL(-1) for NVP, respectively. The method was found to be accurate, with accuracy ranging from -10.92 to +9.57% and precise, with intra-day, inter-day as well as analyst to analyst precision of 0.68 to 9.38%. Extraction recoveries of the drugs from plasma were 91.39, 95.01, 89.51% for ZVD and 90.93, 93.26, 92.13% for NVP, for LQC (low quality control), MQC (medium quality control) and HQC (high quality control) samples, respectively. Stability data revealed that the drugs were stable in plasma under various test conditions. Conclusion: This assay can be suitably used for the determination of zidovudine (ZVD) and nevirapine (NVP) in human plasma and should be useful in HIV clinical trials and clinical therapeutic drug monitoring (TDM) programs. It would also be potentially useful in the determination of pharmacokinetic profiles and in bioequivalence studies in HIV research.
引用
收藏
页码:79 / 86
页数:8
相关论文
共 50 条
  • [21] High-performance liquid chromatography with solid-phase extraction for the quantitative determination of nilotinib in human plasma
    Miura, Masatomo
    Takahashi, Naoto
    Sawada, Ken-ichi
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (07) : 789 - 793
  • [22] SIMULTANEOUS DETERMINATION OF FELBAMATE AND 3 METABOLITES IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ROMANYSHYN, LA
    WICHMANN, JK
    KUCHARCZYK, N
    SOFIA, RD
    THERAPEUTIC DRUG MONITORING, 1994, 16 (01) : 83 - 89
  • [23] Rapid simultaneous determination of voriconazole and its N-oxide in human plasma using an isocratic high-performance liquid chromatography method and its clinical application
    Yamada, Takahiro
    Mino, Yasuaki
    Yagi, Tatsuya
    Naito, Takafumi
    Kawakami, Junichi
    CLINICAL BIOCHEMISTRY, 2012, 45 (1-2) : 134 - 138
  • [24] Ultra Performance Liquid Chromatography PDA Method for Determination of Tigecycline in Human Plasma
    D'Avolio, Antonio
    Peila, Emanuela
    Simiele, Marco
    Pensi, Debora
    Baietto, Lorena
    Cusato, Jessica
    Cinnirella, Giacoma
    De Rosa, Francesco
    Di Perri, Giovanni
    THERAPEUTIC DRUG MONITORING, 2013, 35 (06) : 853 - 858
  • [25] Simple and rapid determination of nevirapine in human serum by reversed-phase high-performance liquid chromatography
    Lopez, RM
    Pou, L
    Gomez, MR
    Ruiz, I
    Monterde, J
    JOURNAL OF CHROMATOGRAPHY B, 2001, 751 (02): : 371 - 376
  • [26] An Improved Reverse Phase High Performance Liquid Chromatography Method for Simultaneous Quantification of Levels of Imidazole Dipeptides and Their Metabolites in Human Plasma
    Shiotani, Shigenobu
    Suzuki, Takanori
    Yoneyama, Akira
    Yanai, Nobuya
    Hagiwara, Shoji
    Nabetani, Hiroshi
    JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 2017, 64 (08): : 437 - 445
  • [27] A quantitative method for the determination of bosutinib in human plasma using high-performance liquid chromatography and ultraviolet detection
    Sumimoto, Takahiro
    Nakahara, Ryosuke
    Sato, Yuhki
    Itoh, Hiroki
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (01)
  • [28] Simultaneous Determination of Lamotrigine and Carbamazepine in Plasma Using Ultrasound-Assisted Emulsification Microextraction-High Performance Liquid Chromatography
    Shahdousti, Parvin
    Aghamohammadi, Mohammad
    Fallahi, Elahe
    Kalhor, Hamideh
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (05) : 622 - 628
  • [29] SIMULTANEOUS DETERMINATION OF RUFLOXACIN AND THEOPHYLLINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY IN HUMAN PLASMA
    CARLUCCI, G
    MAZZEO, P
    PALUMBO, G
    ANALYST, 1995, 120 (10) : 2493 - 2495
  • [30] Simultaneous determination of isoniazid and pyrazinamide in plasma by high performance liquid chromatography
    Mahjoub, Abdallah A.
    Khan, Amer H.
    Sulaiman, Syed A. Syed
    Lajis, Razak
    Man, Che N.
    Ali, Irfhan A. Hyder
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2016, 15 (11) : 2475 - 2481