Assessment of blind source separation techniques for video-based cardiac pulse extraction

被引:17
作者
Wedekind, Daniel [1 ]
Trumpp, Alexander [1 ]
Gaetjen, Frederik [2 ]
Rasche, Stefan [2 ]
Matschke, Klaus [2 ]
Malberg, Hagen [1 ]
Zaunseder, Sebastian [1 ]
机构
[1] Tech Univ Dresden, Inst Biomed Engn, Dresden, Germany
[2] Tech Univ Dresden, Univ Hosp Carl Gustav Carus Dresden, Herzzentrum Dresdem GmbH, Dresden, Germany
关键词
blind source separation; independent component analysis; principal component analysis; video-based vital signs monitoring; camera-based photoplethysmogram; signal-to-noise ratio; EFFECT SIZE; NONCONTACT;
D O I
10.1117/1.JBO.22.3.035002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Blind source separation (BSS) aims at separating useful signal content from distortions. In the contactless acquisition of vital signs by means of the camera-based photoplethysmogram (cbPPG), BSS has evolved the most widely used approach to extract the cardiac pulse. Despite its frequent application, there is no consensus about the optimal usage of BSS and its general benefit. This contribution investigates the performance of BSS to enhance the cardiac pulse from cbPPGs in dependency to varying input data characteristics. The BSS input conditions are controlled by an automated spatial preselection routine of regions of interest. Input data of different characteristics (wavelength, dominant frequency, and signal quality) from 18 postoperative cardiovascular patients are processed with standard BSS techniques, namely principal component analysis (PCA) and independent component analysis (ICA). The effect of BSS is assessed by the spectral signal-tonoise ratio (SNR) of the cardiac pulse. The preselection of cbPPGs, appears beneficial providing higher SNR compared to standard cbPPGs. Both, PCA and ICA yielded better outcomes by using monochrome inputs (green wavelength) instead of inputs of different wavelengths. PCA outperforms ICA for more homogeneous input signals. Moreover, for high input SNR, the application of ICA using standard contrast is likely to decrease the SNR. (C) 2017 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:14
相关论文
共 40 条
[1]   An open-source framework for stress-testing non-invasive foetal ECG extraction algorithms [J].
Andreotti, Fernando ;
Behar, Joachim ;
Zaunseder, Sebastian ;
Oster, Julien ;
Clifford, Gari D. .
PHYSIOLOGICAL MEASUREMENT, 2016, 37 (05) :627-648
[2]  
[Anonymous], 2002, ANSI/AAMI EC13-2002-Cardiac Monitors, Heart Rate Meters, and Alarms
[3]   Detecting Pulse from Head Motions in Video [J].
Balakrishnan, Guha ;
Durand, Fredo ;
Guttag, John .
2013 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2013, :3430-3437
[4]   Ambient and unobtrusive cardiorespiratory monitoring techniques [J].
Brüser, Christoph ;
Antink, Christoph Hoog ;
Wartzek, Tobias ;
Walter, Marian ;
Leonhardt, Steffen .
IEEE Reviews in Biomedical Engineering, 2015, 8 :30-43
[5]   High-order contrasts for independent component analysis [J].
Cardoso, JF .
NEURAL COMPUTATION, 1999, 11 (01) :157-192
[6]  
Christinaki E, 2014, 2014 EAI 4TH INTERNATIONAL CONFERENCE ON WIRELESS MOBILE COMMUNICATION AND HEALTHCARE (MOBIHEALTH), P339, DOI 10.1109/MOBIHEALTH.2014.7015980
[7]   INDEPENDENT COMPONENT ANALYSIS, A NEW CONCEPT [J].
COMON, P .
SIGNAL PROCESSING, 1994, 36 (03) :287-314
[8]   Improved motion robustness of remote-PPG by using the blood volume pulse signature [J].
de Haan, G. ;
van Leest, A. .
PHYSIOLOGICAL MEASUREMENT, 2014, 35 (09) :1913-1926
[9]   Robust Pulse Rate From Chrominance-Based rPPG [J].
de Haan, Gerard ;
Jeanne, Vincent .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (10) :2878-2886
[10]  
Feng LT, 2014, INT CONF DIGIT SIG, P18, DOI 10.1109/ICDSP.2014.6900813