The properties of SIRT, TVM, and DART for 3D imaging of tubular domains in nanocomposite thin-films and sections

被引:41
作者
Chen, Delei [1 ,2 ]
Goris, Bart [3 ]
Bleichrodt, Folkert [4 ]
Mezerji, Hamed Heidari [3 ]
Bals, Sara [3 ]
Batenburg, Kees Joost [4 ]
de With, Gijsbertus [1 ]
Friedrich, Heiner [1 ]
机构
[1] Eindhoven Univ Technol, Dept Chem Engn & Chem, Lab Mat & Interface Chem, NL-5612 AZ Eindhoven, Netherlands
[2] DPI, NL-5600 AX Eindhoven, Netherlands
[3] Univ Antwerp, EMAT, B-2020 Antwerp, Belgium
[4] Ctr Wiskunde & Informat, NL-1098 XG Amsterdam, Netherlands
关键词
Electron tomography; Reconstruction algorithm; Simultaneous iterative reconstruction technique (SIRT); Total variation minimization (TVM); Discrete algebraic reconstruction (DART); Beam-sensitive material; TRANSMISSION ELECTRON MICROTOMOGRAPHY; 3-DIMENSIONAL RECONSTRUCTION; MISSING WEDGE; TOMOGRAPHY; MICROSCOPY; MORPHOLOGY; RESOLUTION; PARTICLES; ART;
D O I
10.1016/j.ultramic.2014.08.005
中图分类号
TH742 [显微镜];
学科分类号
摘要
In electron tomography, the fidelity of the 3D reconstruction strongly depends on the employed reconstruction algorithm. In this paper, the properties of SIRT, TVM and DART reconstructions are studied with respect to having only a limited number of electrons available for imaging and applying different angular sampling schemes. A well-defined realistic model is generated, which consists of tubular domains within a matrix having slab-geometry. Subsequently, the electron tomography work-flow is simulated from calculated Lilt-series over experimental effects to reconstruction. In comparison with the model, the fidelity of each reconstruction method is evaluated qualitatively and quantitatively based on global and local edge profiles and resolvable distance between particles. Results show that the performance of all reconstruction methods declines with the total electron dose. Overall. SIRT algorithm is the most stable method and insensitive to changes in angular sampling. TVM algorithm yields significantly sharper edges in the reconstruction, but the edge positions are strongly influenced by the tilt scheme and the tubular objects become thinned. The DART algorithm markedly suppresses the elongation artifacts along the beam direction and moreover segments the reconstruction which can be considered a significant advantage for quantification. Finally, no advantage of TVM and DART to deal better with fewer projections was observed. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 148
页数:12
相关论文
共 62 条
  • [1] SIMULTANEOUS ALGEBRAIC RECONSTRUCTION TECHNIQUE (SART) - A SUPERIOR IMPLEMENTATION OF THE ART ALGORITHM
    ANDERSEN, AH
    KAK, AC
    [J]. ULTRASONIC IMAGING, 1984, 6 (01) : 81 - 94
  • [2] [Anonymous], 2008, Springer Ser. Opt. Sci.
  • [3] Balakrishnan N., 1992, HDB LOGISTIC DISTRIB
  • [4] Quantitative three-dimensional reconstruction of catalyst particles for bamboo-like carbon nanotubes
    Bals, Sara
    Batenburg, K. Joost
    Verbeeck, Jo
    Sijbers, Jan
    Van Tendeloo, Gustaaf
    [J]. NANO LETTERS, 2007, 7 (12) : 3669 - 3674
  • [5] High resolution electron tomography
    Bals, Sara
    Van Aert, Sandra
    Van Tendeloo, Gustaaf
    [J]. CURRENT OPINION IN SOLID STATE & MATERIALS SCIENCE, 2013, 17 (03) : 107 - 114
  • [6] Quantitative Three-Dimensional Modeling of Zeotile Through Discrete Electron Tomography
    Bals, Sara
    Batenburg, K. Joost
    Liang, Duoduo
    Lebedev, Oleg
    Van Tendeloo, Gustaaf
    Aerts, Alexander
    Martens, Johan A.
    Kirschhock, Christine E. A.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (13) : 4769 - 4773
  • [7] 3D imaging of nanomaterials by discrete tomography
    Batenburg, K. J.
    Bals, S.
    Sijbers, J.
    Kuebel, C.
    Midgley, P. A.
    Hernandez, J. C.
    Kaiser, U.
    Encina, E. R.
    Coronado, E. A.
    Van Tendeloo, G.
    [J]. ULTRAMICROSCOPY, 2009, 109 (06) : 730 - 740
  • [8] DART: A Practical Reconstruction Algorithm for Discrete Tomography
    Batenburg, Kees Joost
    Sijbers, Jan
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2011, 20 (09) : 2542 - 2553
  • [9] Benson TM, 2005, IEEE NUCL SCI CONF R, P2715
  • [10] On Resolution in Electron Tomography of Beam Sensitive Materials
    Chen, Delei
    Friedrich, Heiner
    de With, Gijsbertus
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2014, 118 (02) : 1248 - 1257