Automated pipeline for anatomical phenotyping of mouse embryos using micro-CT

被引:41
作者
Wong, Michael D. [1 ]
Maezawa, Yoshiro [2 ]
Lerch, Jason P. [1 ,3 ]
Henkelman, R. Mark [1 ,3 ]
机构
[1] Hosp Sick Children, Mouse Imaging Ctr, Toronto, ON M5T 3H7, Canada
[2] Mt Sinai Hosp, Lunenfeld Tanenbaum Res Inst, Toronto, ON M5G 1X5, Canada
[3] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 1L7, Canada
来源
DEVELOPMENT | 2014年 / 141卷 / 12期
基金
美国国家卫生研究院;
关键词
Micro-CT; Embryo; 3D; Imaging; Phenotyping; GENE; MODEL; REGISTRATION; SATB2; RESOURCE;
D O I
10.1242/dev.107722
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The International Mouse Phenotyping Consortium (IMPC) plans to phenotype 20,000 single-gene knockout mice to gain an insight into gene function. Approximately 30% of these knockout mouse lines will be embryonic or perinatal lethal. The IMPC has selected three-dimensional (3D) imaging to phenotype these mouse lines at relevant stages of embryonic development in an attempt to discover the cause of lethality using detailed anatomical information. Rate of throughput is paramount as IMPC production centers have been given the ambitious task of completing this phenotyping project by 2021. Sifting through the wealth of data within high-resolution 3D mouse embryo data sets by trained human experts is infeasible at this scale. Here, we present a phenotyping pipeline that identifies statistically significant anatomical differences in the knockout, in comparison with the wild type, through a computer-automated image registration algorithm. This phenotyping pipeline consists of three analyses (intensity, deformation, and atlas based) that can detect missing anatomical structures and differences in volume of whole organs as well as on the voxel level. This phenotyping pipeline was applied to micro-CT images of two perinatal lethal mouse lines: a hypomorphic mutation of the Tcf21 gene (Tcf21-hypo) and a knockout of the Satb2 gene. With the proposed pipeline we were able to identify the majority of morphological phenotypes previously published for both the Tcf21-hypo and Satb2 mutant mouse embryos in addition to novel phenotypes. This phenotyping pipeline is an unbiased, automated method that highlights only those structural abnormalities that survive statistical scrutiny and illustrates them in a straightforward fashion.
引用
收藏
页码:2533 / 2541
页数:9
相关论文
共 50 条
  • [31] Anatomical Variations of the Human Cochlea Determined from Micro-CT and High-Resolution CT Imaging and Reconstruction
    Tang, Jie
    Tang, Xianglong
    Li, Zhenhua
    Liu, Yikang
    Tan, Songhua
    Li, Heng
    Ke, Rongdan
    Wang, Zhi
    Gong, Li
    Tang, Anzhou
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2018, 301 (06): : 1086 - 1095
  • [32] Micro-CT evaluation of rheumatoid arthritis mouse model disease progression: Manual tracings versus semi-automated routines
    Antill, A. C.
    Ballard, D. H.
    Hollister, A. M.
    Rogers, E. J.
    Yang, S.
    Lokitz, S. J.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (06) : 651 - 655
  • [33] Estimation of Mouse Organ Locations Through Registration of a Statistical Mouse Atlas With Micro-CT Images
    Wang, Hongkai
    Stout, David B.
    Chatziioannou, Arion F.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (01) : 88 - 102
  • [34] Beauty is more than skin deep: a non-invasive protocol for invivo anatomical study using micro-CT
    Broeckhoven, Chris
    du Plessis, Anton
    le Roux, Stephan Gerhard
    Mouton, Pieter le Fras Nortier
    Hui, Cang
    METHODS IN ECOLOGY AND EVOLUTION, 2017, 8 (03): : 358 - 369
  • [35] THREE-DIMENSIONAL SEGMENTATION, RECONSTRUCTION AND PHENOTYPING ANALYSIS OF MAIZE KERNEL BASED ON MICRO-CT IMAGES
    Zhang, Ying
    Du, Jianjun
    Ma, Liming
    Pan, Xiaodi
    Wang, Jinglu
    Guo, Xinyu
    FRESENIUS ENVIRONMENTAL BULLETIN, 2018, 27 (06): : 3965 - 3969
  • [36] Micro-imaging of implanted scaffolds using combined MRI and micro-CT
    Klodowski, K.
    Kaminski, J.
    Nowicka, K.
    Tarasiuk, J.
    Wronski, S.
    Swietek, M.
    Blazewicz, M.
    Figiel, H.
    Turek, K.
    Szponder, T.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2014, 38 (06) : 458 - 468
  • [37] Synchrotron X-ray micro-CT as a validation dataset for diffusion MRI in whole mouse brain
    Trinkle, Scott
    Foxley, Sean
    Kasthuri, Narayanan
    La Riviere, Patrick
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (02) : 1067 - 1076
  • [38] Vascular Casting of Adult and Early Postnatal Mouse Lungs for Micro-CT Imaging
    Knutsen, Russell H.
    Gober, Leah M.
    Sukinik, Joseph R.
    Donahue, Danielle R.
    Kronquist, Elise K.
    Levin, Mark D.
    McLean, Sean E.
    Kozel, Beth A.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (160): : 1 - 22
  • [39] Morphological study of the mandibular second molar using a micro-CT
    Chun, Keyoung Jin
    Yoo, Oui Sik
    Lee, Jong Yeop
    PROCEEDINGS OF THE FIFTH IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2007, : 24 - +
  • [40] Interpreting pathologies in extant and extinct archosaurs using micro-CT
    Anne, Jennifer
    Garwood, Russell J.
    Lowe, Tristan
    Withers, Philip J.
    Manning, Phillip L.
    PEERJ, 2015, 3