Relationship between Measurement Errors in Myocardial T1 Mapping and Heart Rate

被引:3
|
作者
Amano, Yasuo [1 ]
Omori, Yuko [1 ]
Yanagisawa, Fumi [1 ]
Ando, Chisato [2 ]
Shinoda, Naoki [2 ]
Suzuki, Yasuyuki [3 ]
Yamamoto, Hiroshi [2 ]
Matsumoto, Naoya [3 ]
机构
[1] Nihon Univ Hosp, Dept Radiol, Tokyo, Japan
[2] Nihon Univ Hosp, Div Radiol Technol, Tokyo, Japan
[3] Nihon Univ Hosp, Dept Cardiol, Tokyo, Japan
基金
日本学术振兴会;
关键词
Myocardium; native T-1 mapping; modified Look-Locker inversion recovery (MOLLI); measurement error; hear rate; CARDIOVASCULAR MAGNETIC-RESONANCE; SENSITIVE INVERSION-RECOVERY;
D O I
10.2463/mrms.mp.2019-0166
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Modified Look-Locker inversion recovery (MOLLI) using a 5s(3s)3s scheme is robust to tachycardia, but some errors are occasionally observed in myocardial T-1 mapping. We sought to evaluate the relationship between measurement errors in T-1 mapping and heart rate (HR) using a confidence map. Methods: We enrolled 69 male patients with normal native T-1 values of the septal myocardium measured by a 5s(3s)3s MOLLI. The degree of measurement errors in the septal myocardium was assessed by two independent observers on a confidence map using a 4-point scale: 0, no errors; 1, errors located on the myocardial contour; 2, errors extended into the myocardial contour; and 3, errors extended into the midwall. We compared the scores of measurement errors and the average, maximum, minimum or variability of the HR indicated during the MOLLI scan (iHR), image phases of MOLLI or left ventricular ejection fraction (LVEF). Results: Patients with score >1 for the septal myocardium had significantly lower minimum iHR than those with a score <= 1 P < 0.01; 49.8 +/- 10.1 vs. 59.6 +/- 9.7 beat per min). Conclusion: The confidence map shows more measurement errors in patients with lower minimum iHR. The myocardial T-1, values should be measured carefully in patients with bradycardia during MOLLI scanning.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 50 条
  • [21] MOLLI and AIR T1 mapping pulse sequences yield different myocardial T1 and ECV measurements
    Hong, KyungPyo
    Kim, Daniel
    NMR IN BIOMEDICINE, 2014, 27 (11) : 1419 - 1426
  • [22] Myocardial T1 Mapping at 3 T: Reference Values and Influencing Factors
    Zhao, Lei
    Li, Song-Nan
    Wang, Lu
    Lin, Hui
    Wen, Song-Nan
    Ning, Man
    Ma, Xiao-Hai
    Yu, Rong-Hui
    Long, De-Yong
    Tang, Ri-Bo
    Sang, Cai-Hua
    Jiang, Chen-Xi
    Du, Xin
    Dong, Jian-Zeng
    Fan, Zhan-Ming
    Ma, Chang-Sheng
    CIRCULATION, 2015, 132
  • [23] Accurate and robust systolic myocardial T1 mapping using saturation recovery with individualized delay time: comparison with diastolic T1 mapping
    Arai H.
    Kawakubo M.
    Sanui K.
    Nishimura H.
    Kadokami T.
    Radiological Physics and Technology, 2018, 11 (4) : 415 - 422
  • [24] Endogenous assessment of chronic myocardial infarction with T1ρ-mapping in patients
    Joep WM van Oorschot
    Hamza El Aidi
    Sanne J Jansen of Lorkeers
    Johannes MIH Gho
    Martijn Froeling
    Fredy Visser
    Steven AJ Chamuleau
    Pieter A Doevendans
    Peter R Luijten
    Tim Leiner
    Jaco JM Zwanenburg
    Journal of Cardiovascular Magnetic Resonance, 16
  • [25] Endogenous Assessment of Diffuse Myocardial Fibrosis in Patients With T1ρ-Mapping
    van Oorschot, Joep W. M.
    Guclu, Fatih
    de Jong, Sanne
    Chamuleau, Steven A. J.
    Luijten, Peter R.
    Leiner, Tim
    Zwanenburg, Jaco J. M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (01) : 132 - 138
  • [26] Myocardial T1 and extracellular volume fraction mapping at 3 tesla
    Jason J Lee
    Songtao Liu
    Marcelo S Nacif
    Martin Ugander
    Jing Han
    Nadine Kawel
    Christopher T Sibley
    Peter Kellman
    Andrew E Arai
    David A Bluemke
    Journal of Cardiovascular Magnetic Resonance, 13
  • [27] Fast myocardial T1 mapping using cardiac motion correction
    Becker, Kirsten M.
    Blaszczyk, Edyta
    Funk, Stephanie
    Nuesslein, Andre
    Schulz-Menger, Jeanette
    Schaeffter, Tobias
    Kolbitsch, Christoph
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (02) : 438 - 451
  • [28] The Value of T1 Mapping Techniques in the Assessment of Myocardial Interstitial Fibrosis
    Andrade Gomes, Helder Jorge
    Vieira Alves, Vinicius de Padua
    Nacif, Marcelo Souto
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2019, 27 (03) : 563 - +
  • [29] Myocardial T1 and Extracellular Volume Fraction Mapping at 3 Tesla
    Lee, Jason J.
    Liu, Songtao
    Nacif, Marcelo S.
    Ugander, Martin
    Han, Jing
    Kawel, Nadine
    Sibley, Christopher T.
    Kellman, Peter
    Arai, Andrew E.
    Bluemke, David A.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13
  • [30] Endogenous assessment of chronic myocardial infarction with T1ρ-mapping in patients
    van Oorschot, Joep W. M.
    El Aidi, Hamza
    Sanne J. Jansen of Lorkeers
    Gho, Johannes M. I. H.
    Froeling, Martijn
    Visser, Fredy
    Chamuleau, Steven A. J.
    Doevendans, Pieter A.
    Luijten, Peter R.
    Leiner, Tim
    Zwanenburg, Jaco J. M.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16