Quantitative analysis of 3-D conformal MRI-guided transurethral ultrasound therapy of the prostate: Theoretical simulations

被引:45
作者
Burtnyk, Mathieu [1 ]
Chopra, Rajiv
Bronskill, Michael J.
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Ultrasound; prostate; thermal therapy; MRI; adaptive; feedback control; INTENSITY FOCUSED ULTRASOUND; THERMAL THERAPY; TEMPERATURE CONTROL; ROTATIONAL CONTROL; CANCER; APPLICATORS; COAGULATION; ABLATION; HYPERTHERMIA; THERMOMETRY;
D O I
10.1080/02656730802578802
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The capability of MRI-guided transurethral ultrasound therapy to produce continuous regions of thermal coagulation that conform to human prostate geometries was evaluated using 3-D anatomical models of prostate cancer patients. Methods: Numerical simulations incorporating acoustic and biothermal modeling and a novel temperature control feedback algorithm were used to evaluate treatment accuracy of a rotating dual-frequency multi-element transducer. Treatments were simulated on twenty anatomical models obtained from the manual segmentation of the prostate and surrounding structures on MR images of prostate cancer patients obtained prior to radical prostatectomy. Results: Regions of thermal coagulation could be accurately shaped to predefined volumes within 1 mm across the vast majority of the prostates. Over- and under-treated volumes remained smaller than 4% of the corresponding prostate volumes which ranged from 14 to 60 cc. Treatment times were typically 30 min and remained below 60 min even for large 60 cc prostates. Heating of the rectal wall remained below 30 min43C in half of the patient models with only minor, superficial heating in the other cases. The simulated feedback control algorithm adjusted the ultrasound transducer parameters such that high treatment accuracy was maintained despite variable blood perfusion, changing tissue ultrasound attenuation, and practical temperature measurement noise and sampling rate. Conclusions: Numerical simulations predict that MRI-guided transurethral ultrasound therapy is capable of producing highly accurate volumes of thermal coagulation that conform to human prostate glands.
引用
收藏
页码:116 / 131
页数:16
相关论文
共 53 条
  • [1] *AM CANC SOC, 2007, AM CANC STAT
  • [2] [Anonymous], 1990, PHYS PROPERTIES TISS
  • [3] Control of thermal therapies with moving power deposition field
    Arora, D
    Minor, MA
    Skliar, M
    Roemer, RB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (05) : 1201 - 1219
  • [4] High-intensity focused ultrasound for the treatment of localized prostate cancer: 5-year experience
    Blana, A
    Walter, B
    Rogenhofer, S
    Wieland, WF
    [J]. UROLOGY, 2004, 63 (02) : 297 - 300
  • [5] Prostate tissue analysis immediately following magnetic resonance imaging guided transurethral ultrasound thermal therapy
    Boyes, Aaron
    Tang, Kee
    Yaffe, Martin
    Sugar, Linda
    Chopra, Rajiv
    Bronskill, Michael
    [J]. JOURNAL OF UROLOGY, 2007, 178 (03) : 1080 - 1085
  • [6] Prostate cancer: Evaluation of vascular characteristics with dynamic contrast-enhanced T1-weighted MR imaging - Initial experience
    Buckley, DL
    Roberts, C
    Parker, GJM
    Logue, JP
    Hutchinson, CE
    [J]. RADIOLOGY, 2004, 233 (03) : 709 - 715
  • [7] BURTNYK M, 2007, P INT S THER ULTR SE
  • [8] *CAN CANC SOC, 2007, CAN CANC STAT
  • [9] Individualized planning target volumes for intrafraction motion during hypofractionated intensity-modulated radiotherapy boost for prostate cancer
    Cheung, P
    Sixel, K
    Morton, G
    Loblaw, DA
    Tirona, R
    Pang, G
    Choo, R
    Szumacher, E
    DeBoer, G
    Pignol, JP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02): : 418 - 425
  • [10] Analysis of factors important for transurethral ultrasound prostate heating using MR temperature feedback
    Chopra, R
    Wachsmuth, J
    Burtnyk, M
    Haider, MA
    Bronskill, MJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (04) : 827 - 844