Blood pressure measurement using finger cuff

被引:5
|
作者
Lee, J. Y. [1 ]
Choi, E. Y. [1 ]
Jeong, H. J. [1 ]
Kim, K. H. [1 ]
Park, J. C. [1 ]
机构
[1] Samsung Adv Inst Technol, Gyeonggi 449712, South Korea
关键词
D O I
10.1109/IEMBS.2005.1617252
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Many research groups have studied blood pressure measurement in finger artery because of its convenience. But, low accuracy prohibits many hypertension patients from using this device. So, we suggest measurement algorithm that measure systolic and diastolic blood pressure in finger artery. And we also develop calibration method that decreases the error from difference of finger circumference by subjects. We apply our methods for 90 subjects (age form 20 to 49, 55 male, 35 female) to test feasibility of our method by AAMI SP10 standard. The mean difference of our system is +/- 4.7mmHg for systotic pressure, +/- 4.2mmHg for systolic pressure. It proved that the feasibility of our method is clinically acceptable.(under +/- 5mmHg).
引用
收藏
页码:3575 / 3577
页数:3
相关论文
共 50 条
  • [31] Noninvasive Blood Pressure Measurement in Maintenance Hemodialysis Patients: Comparison of Agreement between Oscillometric and Finger-Cuff Methods
    Alfano, Gaetano
    Fontana, Francesco
    Cappelli, Gianni
    NEPHRON, 2017, 136 (04) : 309 - 317
  • [32] Novel Method of Automatic Auscultation for Blood Pressure Measurement Using Pulses in Cuff Pressure and Korotkoff Sound
    Park, D. K.
    Oh, H. S.
    Kang, J. H.
    Kim, I. Y.
    Chee, Y. J.
    Lee, J. S.
    COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2, 2008, : 181 - +
  • [33] Continuous blood pressure monitoring with a finger cuff is unreliable in chronic hemodialysis patients
    Chaara, Sabrine
    Rootjes, Paul
    Wijngaarden, Gertrude
    Nube, Menso
    van Zuijdewijn, Camiel de Roij
    Grooteman, Muriel
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39
  • [34] Continuous blood pressure monitoring with a finger cuff is unreliable in chronic hemodialysis patients
    Chaara, Sabrine
    Rootjes, Paul
    Wijngaarden, Gertrude
    Nube, Menso
    van Zuijdewijn, Camiel de Roij
    Grooteman, Muriel
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39 : I1242 - I1243
  • [35] RELEVANCE OF THE WATERFALL PHENOMENON IN CONTINUOUS FINGER CUFF BLOOD-PRESSURE MEASUREMENTS
    KOBLER, H
    CEJNAR, M
    HUNYOR, SN
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1991, 18 (05): : 323 - 326
  • [36] Accuracy improvement of noninvasive finger blood pressure measurement
    Lackovic, I
    Santic, A
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 281 - 284
  • [37] Recent advances in blood pressure measurement technology: normalized blood pressure measurement with a double-cuff sphygmotonometer
    Tochikubo, O
    Kimura, K
    BLOOD PRESSURE MONITORING, 2001, 6 (06) : 297 - 301
  • [38] Effect of altering vasoactivity on the measurement of finger blood pressure
    Jagomägi, K
    Raamat, R
    Talts, J
    BLOOD PRESSURE MONITORING, 2001, 6 (01) : 33 - 40
  • [39] A Hydrostatic Pressure Approach to Assess Accuracy of Finger Blood Pressure Measurement
    Raamat, Rein
    Jagomagi, Kersti
    Talts, Jaak
    Kivastik, Jana
    2009 9TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, 2009, : 221 - 224
  • [40] A Hydrostatic Pressure Approach to Assess Accuracy of Finger Blood Pressure Measurement
    Raamat, Rein
    Jagomagi, Kersti
    Talts, Jaak
    Kivastik, Jana
    2009 9TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, 2009, : 36 - 39