Blood pressure measurement using finger cuff

被引:5
|
作者
Lee, J. Y. [1 ]
Choi, E. Y. [1 ]
Jeong, H. J. [1 ]
Kim, K. H. [1 ]
Park, J. C. [1 ]
机构
[1] Samsung Adv Inst Technol, Gyeonggi 449712, South Korea
关键词
D O I
10.1109/IEMBS.2005.1617252
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Many research groups have studied blood pressure measurement in finger artery because of its convenience. But, low accuracy prohibits many hypertension patients from using this device. So, we suggest measurement algorithm that measure systolic and diastolic blood pressure in finger artery. And we also develop calibration method that decreases the error from difference of finger circumference by subjects. We apply our methods for 90 subjects (age form 20 to 49, 55 male, 35 female) to test feasibility of our method by AAMI SP10 standard. The mean difference of our system is +/- 4.7mmHg for systotic pressure, +/- 4.2mmHg for systolic pressure. It proved that the feasibility of our method is clinically acceptable.(under +/- 5mmHg).
引用
收藏
页码:3575 / 3577
页数:3
相关论文
共 50 条
  • [1] EVALUATION OF OSCILLOMETRIC BLOOD PRESSURE MEASUREMENT USING A FINGER CUFF IN ANESTHETIZED CHIMPANZEES (PAN TROGLODYTES)
    Cassady, Katherine R.
    Balko, Julie A.
    Bailey, Kate M.
    Posner, Lysa P.
    Robertson, James B.
    Minter, Larry J.
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2023, 54 (01) : 16 - 22
  • [2] THE FINAPRES 2300E FINGER CUFF - THE INFLUENCE OF CUFF APPLICATION ON THE ACCURACY OF BLOOD-PRESSURE MEASUREMENT
    JONES, RDM
    KORNBERG, JP
    ROULSON, CJ
    VISRAM, AR
    IRWIN, MG
    ANAESTHESIA, 1993, 48 (07) : 611 - 615
  • [3] ROLE OF FINGER CUFF BLOOD-PRESSURE DETERMINATIONS
    ALSAYANI, M
    MEMOLI, DJ
    MYERS, KR
    BERLIN, D
    COUGHLIN, SS
    EARLL, JM
    CLINICAL RESEARCH, 1991, 39 (01): : A124 - A124
  • [4] Arm cuff in the measurement of blood pressure
    Mattoo, TK
    AMERICAN JOURNAL OF HYPERTENSION, 2002, 15 (02) : 67S - 68S
  • [5] Cuff challenges in blood pressure measurement
    Palatini, Paolo
    Asmar, Roland
    JOURNAL OF CLINICAL HYPERTENSION, 2018, 20 (07): : 1100 - 1103
  • [6] BLOOD-PRESSURE MEASUREMENT USING OSCILLOMETRIC FINGER CUFFS
    OBRIEN, E
    ATKINS, N
    ANAESTHESIA, 1995, 50 (08) : 743 - 744
  • [7] Use of a neonatal blood pressure cuff to monitor blood pressure in the adult finger comparison with a standard adult arm cuff
    Khan, SQ
    Wardlaw, JM
    Davenport, R
    Slattery, J
    Lewis, S
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1998, 14 (04) : 233 - 238
  • [8] Use of A Neonatal Blood Pressure Cuff to Monitor Blood Pressure In The Adult Finger – Comparison With A Standard Adult Arm Cuff
    Sohail Q Khan
    Joanna M. Wardlaw
    Richard Davenport
    Jim Slattery
    Stephanie Lewis
    Journal of Clinical Monitoring and Computing, 1998, 14 : 233 - 238
  • [9] Correct placement of blood pressure cuff during blood pressure measurement
    Garcia, Mary Grace Uranza
    Ang, Emily
    Ahmad, Noor Melati
    Lim, Chi Ching
    INTERNATIONAL JOURNAL OF EVIDENCE-BASED HEALTHCARE, 2012, 10 (03): : 191 - 196
  • [10] SPHYGMOMANOMETER CUFF SIZE AND BLOOD PRESSURE MEASUREMENT
    SHEKELLE, RB
    BULLETIN OF THE WORLD HEALTH ORGANIZATION, 1965, 33 (02) : 284 - &