Numerical Analyses of High Concentrator Triple-Junction Solar Cell under Jet Impingement Cooling
被引:8
|
作者:
Abo-Zahhada, Essam M.
论文数: 0引用数: 0
h-index: 0
机构:
Egypt Japan Univ Sci & Technol, Alexandria 21934, Egypt
Aswan Univ, Fac Energy Engn, Mech Power Engn Dept, Aswan 81528, EgyptEgypt Japan Univ Sci & Technol, Alexandria 21934, Egypt
Abo-Zahhada, Essam M.
[1
,2
]
Ookawara, Shinichi
论文数: 0引用数: 0
h-index: 0
机构:
Tokyo Inst Technol, Dept Chem Sci & Engn, Tokyo 1528552, JapanEgypt Japan Univ Sci & Technol, Alexandria 21934, Egypt
Ookawara, Shinichi
[3
]
Radwan, Ali
论文数: 0引用数: 0
h-index: 0
机构:
Mansoura Univ, Mech Power Engn Dept, Mansoura 35516, EgyptEgypt Japan Univ Sci & Technol, Alexandria 21934, Egypt
Radwan, Ali
[4
]
El-Shazly, A. H.
论文数: 0引用数: 0
h-index: 0
机构:
Egypt Japan Univ Sci & Technol, Alexandria 21934, EgyptEgypt Japan Univ Sci & Technol, Alexandria 21934, Egypt
El-Shazly, A. H.
[1
]
论文数: 引用数:
h-index:
机构:
El-Kady, M. F.
[1
]
机构:
[1] Egypt Japan Univ Sci & Technol, Alexandria 21934, Egypt
[2] Aswan Univ, Fac Energy Engn, Mech Power Engn Dept, Aswan 81528, Egypt
[3] Tokyo Inst Technol, Dept Chem Sci & Engn, Tokyo 1528552, Japan
[4] Mansoura Univ, Mech Power Engn Dept, Mansoura 35516, Egypt
来源:
CLEANER ENERGY FOR CLEANER CITIES
|
2018年
/
152卷
关键词:
High Concentrator Photovoltaic;
Triple-Junction Solar Cell;
High Concentrations;
Thermal Stress;
PHOTOVOLTAIC CELLS;
THIN-FILMS;
PERFORMANCE;
PV;
D O I:
10.1016/j.egypro.2018.09.119
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
The triple junction III-V(TJ) solar cells are commonly used for the high concentrator photovoltaic (HCPV) arrangements as they have high efficiency and have a good response to high concentration. Nevertheless, the efficiency of solar cells decreases with an increase of temperature especially under high solar irradiance concentration ratios where the temperature of solar cells reaches to very high levels. Consequently, heat dissipation by cooling is crucial for a concentrator photovoltaic solar cell at high concentration. Moreover, significant temperature difference possibly will exist within the cell body, so it is vital to identify the presence of thermal stresses that can cause failure and deformation of the cell body. This work investigated the capability of impinging jet cooling technique to maintain a triple junction solar cell temperature under recommended operating conditions. Furthermore, thermal stress analyses were performed. The results showed that employing jet impingements cooling improved both of thermal energy and electrical generation. In addition, the thermal stress is considerably decreased with increasing the cooling inlet mass flow rate. Copyright (C) 2018 Elsevier Ltd. All rights reserved. Selection and peer-review under responsibility of the scientific committee of the CUE2018-Applied Energy Symposium and Forum 2018: Low carbon cities and urban energy systems.
机构:
Univ Salerno, Dept Ind Engn, Via Giovanni Paolo 2,132, I-84084 Salerno, ItalyUniv Salerno, Dept Ind Engn, Via Giovanni Paolo 2,132, I-84084 Salerno, Italy
Renno, C.
论文数: 引用数:
h-index:
机构:
Landi, G.
论文数: 引用数:
h-index:
机构:
Petito, F.
Neitzert, H. C.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Salerno, Dept Ind Engn, Via Giovanni Paolo 2,132, I-84084 Salerno, ItalyUniv Salerno, Dept Ind Engn, Via Giovanni Paolo 2,132, I-84084 Salerno, Italy