Are stentless valves superior to modern stented valves? A prospective randomized trial

被引:67
作者
Ali, A [1 ]
Halstead, JC
Cafferty, F
Sharples, L
Rose, F
Coulden, R
Lee, E
Dunning, J
Argano, V
Tsui, S
机构
[1] Papworth Hosp, Dept Cardiothorac Surg, Cambridge CB3 8RE, England
[2] Morriston Hosp, Dept Cardiothorac Surg, Swansea, W Glam, Wales
关键词
aortic stenosis; aortic valve; surgery; valve replacement; valves;
D O I
10.1161/CIRCULATIONAHA.105.000950
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - It is presumed that stentless aortic bioprostheses are hemodynamically superior to stented bioprostheses. A prospective randomized controlled trial was undertaken to compare stentless versus modern stented valves. Methods and Results - Patients with severe aortic valve stenosis ( n = 161) undergoing aortic valve replacement (AVR) were randomized intraoperatively to receive either the C-E Perimount stented bioprosthesis (n = 81) or the Prima Plus stentless bioprosthesis (n = 80). We assessed left ventricular mass (LVM) regression with transthoracic echocardiography (TTE) and magnetic resonance imaging (MRI). Transvalvular gradients were measured postoperatively by Doppler echocardiography to compare hemodynamic performance. There was no difference between groups with regard to age, symptom status, need for concomitant coronary artery bypass surgery, or baseline LVM. LVM regressed in both groups but with no significant difference between groups at 1 year. In a subset of 50 patients, MRI was also used to assess LVM regression, and again there was no significant difference between groups at 1 year. Hemodynamic performance of the 2 valves was similar with no difference in mean and peak systolic transvalvular gradients 1 year after surgery. In patients with reduced ventricular function (left ventricular ejection fraction [LVEF] < 60%), there was a significantly greater improvement in LVEF from baseline to 1 year in stentless valve recipients. Conclusions - Both stented and stentless bioprostheses are associated with excellent clinical and hemodynamic outcomes 1 year after AVR. Comparable hemodynamics and LVM regression can be achieved using a second- generation stented pericardial bioprosthesis. In patients with ventricular impairment, stentless bioprostheses may allow for greater improvement in left ventricular function postoperatively.
引用
收藏
页码:I535 / I540
页数:6
相关论文
共 18 条
  • [1] ALI A, IN PRESS J HEART VAL
  • [2] Are stentless valves hemodynamically superior to stented valves? A prospective randomized trial
    Cohen, G
    Christakis, GT
    Joyner, CD
    Morgan, CD
    Tamariz, M
    Hanayama, N
    Mallidi, H
    Szalai, JP
    Katic, M
    Rao, V
    Fremes, SE
    Goldman, BS
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (03) : 767 - 775
  • [3] David T E, 1992, J Heart Valve Dis, V1, P244
  • [4] Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis
    Dellgren, G
    David, TE
    Raanani, E
    Armstrong, S
    Ivanov, J
    Rakowski, H
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (01) : 146 - 154
  • [5] DELRIZZO DF, 1996, J THORAC CARDIOVASC, V112, P143
  • [6] Performance of stentless versus stented aortic valve bioprostheses in the elderly patient: a prospective randomized trial
    Doss, M
    Martens, S
    Wood, JP
    Aybek, T
    Kleine, P
    Greinecker, GW
    Moritz, A
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 23 (03) : 299 - 303
  • [7] Guidelines for reporting morbidity and mortality after cardiac valvular operations
    Edmunds, LH
    Clark, RE
    Cohn, LH
    Grunkemeier, GL
    Miller, DC
    Weisel, RD
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (03) : 708 - 711
  • [8] THE PROGNOSTIC ROLE OF LEFT-VENTRICULAR HYPERTROPHY IN PATIENTS WITH OR WITHOUT CORONARY-ARTERY DISEASE
    GHALI, JK
    LIAO, YL
    SIMMONS, B
    CASTANER, A
    CAO, GC
    COOPER, RS
    [J]. ANNALS OF INTERNAL MEDICINE, 1992, 117 (10) : 831 - 836
  • [9] Effects of valve substitute on changes in left ventricular function and hypertrophy after aortic valve replacement
    Jin, XY
    Zhang, ZM
    Gibson, DG
    Yacoub, MH
    Pepper, JR
    [J]. ANNALS OF THORACIC SURGERY, 1996, 62 (03) : 683 - 690
  • [10] Ten-year echocardiographic and clinical follow-up of aortic Carpentier-Edwards pericardial and supraannular prosthesis: A case-match study
    Le Tourneau, T
    Vincentelli, A
    Fayad, G
    Savoye, C
    Fabre, OH
    Prat, A
    Warembourg, H
    [J]. ANNALS OF THORACIC SURGERY, 2002, 74 (06) : 2010 - 2015