Edge detector-based automatic segmentation of the skin layers and application to moisturization in high-resolution 3 Tesla magnetic resonance imaging

被引:5
|
作者
Ognard, Julien [1 ,2 ]
Mesrar, Jawad [1 ,2 ]
Benhoumich, Younes [2 ]
Misery, Laurent [3 ,4 ]
Burdin, Valerie [2 ,5 ]
Ben Salem, Douraied [1 ,2 ]
机构
[1] Univ Hosp Brest, Dept Radiol, Brest, France
[2] INSERM, UMR 1101, Lab Med Informat Proc LaT, Brest, France
[3] Univ Hosp Brest, Dept Dermatol, Brest, France
[4] Lab Epithelium Neurons Interact LIEN EA4685, Brest, France
[5] IMT Atlantique, Mines Telecom Inst, Plouzane, France
关键词
3T MRI; canny filter; moisturization; registration; segmentation; skin; T2; mapping; IN-VIVO; THICKNESS; IMAGES; WATER; MRI;
D O I
10.1111/srt.12654
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Introduction Previous studies have demonstrated the feasibility to explore moisturization with quantification imaging based on T2 mapping. The aim of this study was to describe and validate the first robust automated method to segment the first layers of the skin. Materials and Methods Data were picked from a previous study that included 35 healthy subjects who underwent a 3T MRI (multi spin echo calculation T2-weighted sequence) with a microscopic coil on the left heel before and one hour after moisturization. The automatic algorithm was composed of the T2 map generation, a Canny filter, a selection of boundaries, and a local regression to delimitate stratum corneum, epidermis, and dermis. An automated affine registration was applied between the exams before and after moisturization. Results The failure rate of the algorithm was below 5%. Mean computation time was 139.12s. There was a significant and strong correlation between the automatic measurements and the manual ones for the T2 values (rho: 0.905, P < 0.001) and for the thickness measurements (rho: 0.8663; P < 0.001). For registration, mean of the Dice index was 0.64 [0.47; 0.80] and of the Hausdorff distance was 0.29 mm 95% CI: [0.28; 0.30]. Conclusion The proposed automatic method to study the first skin layers in 3T MRI using micro-coils was robust and described T2 values and thickness measurements with a strong correlation to manual measurements. The use of an automated affine registration could also permit the generation of a mapping for a visual assessment of moisturization.
引用
收藏
页码:339 / 346
页数:8
相关论文
共 50 条
  • [1] In vivo skin moisturizing measurement by high-resolution 3 Tesla magnetic resonance imaging
    Mesrar, J.
    Ognard, J.
    Garetier, M.
    Chechin, D.
    Misery, L.
    Ben Salem, D.
    SKIN RESEARCH AND TECHNOLOGY, 2017, 23 (03) : 289 - 294
  • [2] High-Resolution, In Vivo Magnetic Resonance Imaging of Drosophila at 18.8 Tesla
    Null, Brian
    Liu, Corey W.
    Hedehus, Maj
    Conolly, Steven
    Davis, Ronald W.
    PLOS ONE, 2008, 3 (07):
  • [3] Automatic deep learning segmentation of the hippocampus on high-resolution diffusion magnetic resonance imaging and its application to the healthy lifespan
    Miller, Dylan
    Efird, Cory
    Solar, Kevin Grant
    Beaulieu, Christian
    Cobzas, Dana
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [4] High-resolution magnetic resonance imaging of trabecular bone in the wrist at 3 tesla: Initial results
    Ludescher, B
    Martirosian, P
    Lenk, S
    Machann, J
    Dammann, F
    Schick, F
    Claussen, C
    Schlemmer, H
    ACTA RADIOLOGICA, 2005, 46 (03) : 306 - 309
  • [5] IN-VIVO HYDRATION PROFILE IN SKIN LAYERS BY HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING
    QUERLEUX, B
    RICHARD, S
    BITTOUN, J
    JOLIVET, O
    IDYPERETTI, I
    BAZIN, R
    LEVEQUE, JL
    SKIN PHARMACOLOGY, 1994, 7 (04): : 210 - 216
  • [6] High-resolution magnetic resonance imaging reveals nuclei of the human amygdala: manual segmentation to automatic atlas
    Saygin, Z. M.
    Kliemann, D.
    Iglesias, J. E.
    van der Kouwe, A. J. W.
    Boyd, E.
    Reuter, M.
    Stevens, A.
    Van Leemput, K.
    McKee, A.
    Frosch, M. P.
    Fischl, B.
    Augustinack, J. C.
    NEUROIMAGE, 2017, 155 : 370 - 382
  • [7] Flexible 23-channel coil array for high-resolution magnetic resonance imaging at 3 Tesla
    Frass-Kriegl, Roberta
    de Lara, Lucia Isabel Navarro
    Pichler, Michael
    Sieg, Juergen
    Moser, Ewald
    Windischberger, Christian
    Laistler, Elmar
    PLOS ONE, 2018, 13 (11):
  • [8] In Vivo High-Resolution Magnetic Resonance Skin Imaging at 1.5 T and 3 T
    Barral, Joelle K.
    Bangerter, Neal K.
    Hu, Bob S.
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) : 790 - 796
  • [9] Fast and quantitative high-resolution magnetic resonance imaging of the optic nerve at 3.0 tesla
    Weigel, M
    Lagrèze, WA
    Lazzaro, A
    Hennig, JG
    Bley, TA
    INVESTIGATIVE RADIOLOGY, 2006, 41 (02) : 83 - 86
  • [10] Comparison of 1.5 and 8 Tesla high-resolution magnetic resonance imaging of lacunar infarcts
    Chakeres, DW
    Abduljalil, AM
    Novak, P
    Novak, V
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (04) : 628 - 632