Strategies for formulating appropriate MDCT techniques when imaging the chest, abdomen, and pelvis in pediatric patients

被引:79
作者
Cody, DD
Moxley, DM
Krugh, KT
O'Daniel, JC
Wagner, LK
Eftekhari, F
机构
[1] Univ Texas, MD Anderson Canc Ctr, Div Diagnost Imaging, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[3] Univ Texas, Sch Med, Dept Radiol, Houston, TX 77030 USA
关键词
D O I
10.2214/ajr.182.4.1820849
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. Our aim was to formulate appropriate MDCT chest and abdominopelvic CT scan protocols for pediatric patients. Materials and Methods. Surface radiation dose measurements from a set of anthropomorphic phantoms (nominal 1 year old, 5 year old, and 10 year old) and an adult phantom were compared with standard CT dose index measurements. Image-noise values on axial 5-mm-thick anthropomorphic phantom images were obtained as a measure of image quality. Results. Peripheral CT dose index values obtained with the standard 16-cm acrylic phantom were within approximately 10% of the CT surface dose measurements for the pediatric anthropomorphic phantoms for both chest and abdominopelvic scan protocols. The noise value for the adult phantom image acquired using a typical clinical CT technique was identified, and targeting this level of noise for pediatric CT examinations resulted in a decrease in dose of 60-90%. Initially, 80 kVp was selected for use with very small children; however, beam-hardening artifacts were severe enough to cause us to abandon this option. Current pediatric protocols at M. D. Anderson Cancer Center rely on 100- and 120-kVp settings. The display field-of-view parameter can be used as a surrogate for patient size to develop clinical pediatric CT protocol charts. Conclusion. CT dose index measurements obtained using the 16-cm standard acrylic phantom are sufficiently accurate for estimating chest and abdominopelvic CT entrance exposures for pediatric patients of the same approximate size as the anthropomorphic phantoms used in this study. Image-noise measurements can be used to adjust chest and abdominopelvic CT techniques for pediatric populations, resulting in a decrease in measured entrance dose by 60-90%.
引用
收藏
页码:849 / 859
页数:11
相关论文
共 17 条
  • [1] BLANCK C, 1998, UNDERSTANDING HELICA, P18
  • [2] Panel discussion
    Bleyer, A
    Ron, E
    Rosen, N
    Brenner, D
    Slovis, T
    Staab, E
    Berdon, W
    Strife, J
    [J]. PEDIATRIC RADIOLOGY, 2002, 32 (04) : 242 - 244
  • [3] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [4] Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital
    Donnelly, LF
    Emery, KH
    Brody, AS
    Laor, T
    Gylys-Morin, VM
    Anton, CG
    Thomas, SR
    Frush, DP
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 303 - 306
  • [5] Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients
    Frush, DP
    Slack, CC
    Hollingsworth, CL
    Bisset, GS
    Donnelly, LF
    Hsieh, J
    Lavin-Wensell, T
    Mayo, JR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) : 1107 - 1113
  • [6] On the use of pediatric phantoms in the dose evaluation during computed tomography (CT) thorax examinations
    Giacco, G
    Cannata, V
    Furetta, C
    Santopietro, F
    Fariello, G
    [J]. MEDICAL PHYSICS, 2001, 28 (02) : 199 - 204
  • [7] THE EFFECT OF MAS VARIATION UPON COMPUTED-TOMOGRAPHY IMAGE QUALITY AS EVALUATED BY INVIVO AND INVITRO STUDIES
    HAAGA, JR
    MIRALDI, F
    MACINTYRE, W
    LIPUMA, JP
    BRYAN, PJ
    WIESEN, E
    [J]. RADIOLOGY, 1981, 138 (02) : 449 - 454
  • [8] Radiation dose management: Weighing risk versus benefit
    Haaga, JR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (02) : 289 - 291
  • [9] Technique factors and image quality as functions of patient weight at abdominal CT
    Huda, W
    Scalzetti, EM
    Levin, G
    [J]. RADIOLOGY, 2000, 217 (02) : 430 - 435
  • [10] Effective doses to patients undergoing thoracic computed tomography examinations
    Huda, W
    Scalzetti, EM
    Roskopf, M
    [J]. MEDICAL PHYSICS, 2000, 27 (05) : 838 - 844