Calibration of the 10HS Soil Moisture Sensor for Southwest Florida Agricultural Soils

被引:28
作者
Spelman, David [1 ]
Kinzli, Kristoph-Dietrich [2 ]
Kunberger, Tanya [2 ]
机构
[1] Univ Florida, Gainesville, FL 32611 USA
[2] Florida Gulf Coast Univ, Whitaker Coll Engn, Ft Myers, FL 33965 USA
关键词
Irrigation; Soil water; Calibration; Water use; Florida; Agriculture; Probe instruments; Irrigation practices; WATER;
D O I
10.1061/(ASCE)IR.1943-4774.0000647
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Precision irrigation is crucial in decreasing water demands of irrigated agriculture, which account for the largest source of water withdrawal in most regions. One necessity of precision irrigation is the knowledge of soil moisture content in the root zone of irrigated crops. Dielectric soil moisture sensors can provide this information at a relatively low cost ($100) compared with other techniques; however, their accuracy cannot be guaranteed in all soils without site-specific calibration, the need for which has limited the use of these sensors. This study examined the Decagon 10HS soil moisture sensor in order to determine the accuracy of the manufacturer-supplied calibration equation on southwest Florida (SWFL) agricultural soils, and analyze whether it performs consistently in different soils found in SWFL. Laboratory calibration of the 10HS was done on four SWFL soils that represent the majority of agricultural land in the region and regression calibration equations were obtained. It was found that the manufacturer calibration equation does not accurately predict soil volumetric water content (VWC) within the +/- 3% accuracy range specified for the sensor, meriting the need for site-specific calibration. Additionally, it was found that all tested soils behave very similarly, allowing the development of a single calibration equation for use of the 10HS in all SWFL agricultural applications. The calibration equation developed during this research for SWFL could allow a more widespread use of the 10HS in the region. (C) 2013 American Society of Civil Engineers.
引用
收藏
页码:965 / 971
页数:7
相关论文
共 15 条
[1]  
[Anonymous], 10HS VOLUME SENSITIV
[2]  
Cobos D., 2010, VIRTUAL SEMINAR WHY
[3]  
Cobos D.R., 2010, Calibrating ECH2O soil moisture sensors
[4]  
Decagon Devices, 2008, 10HS SOIL MOIST SENS
[5]   Comparison of three dielectric moisture sensors for measurement of water in saline sandy soil [J].
Inoue, M. ;
Ahmed, B. A. Ould ;
Saito, T. ;
Irshad, M. ;
Uzoma, K. C. .
SOIL USE AND MANAGEMENT, 2008, 24 (02) :156-162
[6]   Comparison of Laboratory and Field Calibration of a Soil-Moisture Capacitance Probe for Various Soils [J].
Kinzli, Kristoph-Dietrich ;
Manana, Nkosinathi ;
Oad, Ramchand .
JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 2012, 138 (04) :310-321
[7]   Frequency, electrical conductivity and temperature analysis of a low-cost capacitance soil moisture sensor [J].
Kizito, F. ;
Campbell, C. S. ;
Campbell, G. S. ;
Cobos, D. R. ;
Teare, B. L. ;
Carter, B. ;
Hopmans, J. W. .
JOURNAL OF HYDROLOGY, 2008, 352 (3-4) :367-378
[8]   Comparison of four soil moisture sensor types under field conditions in Switzerland [J].
Mittelbach, Heidi ;
Lehner, Irene ;
Seneviratne, Sonia I. .
JOURNAL OF HYDROLOGY, 2012, 430 :39-49
[9]  
Obreza T.A., 2002, COMMON SOILS USED CI, P193
[10]   In situ comparison of three dielectric soil moisture sensors in drip irrigated sandy soils [J].
Plauborg, F ;
Iversen, BV ;
Lærke, PE .
VADOSE ZONE JOURNAL, 2005, 4 (04) :1037-1047