Tibial component rotation in total knee arthroplasty

被引:19
|
作者
Feczko, Peter Z. [1 ]
Pijls, Bart G. [1 ]
van Steijn, Michael J. [1 ]
van Rhijn, Lodewijk W. [1 ]
Arts, Jacobus J. [1 ]
Emans, Peter J. [1 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Orthopaed Surg, POB 5800, NL-6202 AZ Maastricht, Netherlands
来源
关键词
Total knee arthroplasty; Tibial rotation; ROM technique; TTL technique; Computer navigation; FEMORAL COMPONENT; ALIGNMENT; REPLACEMENT; ACCURACY; EVENTS; TRAY; MALROTATION; PROSTHESIS; TOURNIQUET; REGRESSION;
D O I
10.1186/s12891-016-0940-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Both the range of motion (ROM) technique and the tibial tubercle landmark (TTL) technique are frequently used to align the tibial component into proper rotational position during total knee arthroplasty (TKA). The aim of the study was to assess the intra-operative differences in tibial rotation position during computer-navigated primary TKA using either the TTL or ROM techniques. The ROM technique was hypothesized to be a repeatable method and to produce different tibial rotation positions compared to the TTL technique. Methods: A prospective, observational study was performed to evaluate the antero-posterior axis of the cut proximal tibia using both the ROM and the TTL technique during primary TKA without postoperative clinical assessment. Computer navigation was used to measure this difference in 20 consecutive knees of 20 patients who underwent a posterior stabilized total knee arthroplasty with a fixed-bearing polyethylene insert and a patella resurfacing. Results: The ROM technique is a repeatable method with an interclass correlation coefficient (ICC2) of 0.84 (p < 0.001). The trial tibial baseplate was on average 4.56 degrees externally rotated compared to the tubercle landmark. This difference was statistically significant (p = 0.028). The amount of maximum intra-operative flexion and the pre-operative mechanical axis were positively correlated with the magnitude of difference between the two methods. Conclusions: It is important for the orthopaedic surgeon to realise that there is a significant difference between the TTL technique and ROM technique when positioning the tibial component in a rotational position. This difference is correlated with high maximum flexion and mechanical axis deviations.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Tibial component rotation in total knee arthroplasty
    Peter Z. Feczko
    Bart G. Pijls
    Michael J. van Steijn
    Lodewijk W. van Rhijn
    Jacobus J. Arts
    Peter J. Emans
    BMC Musculoskeletal Disorders, 17
  • [2] The effect of femoral component external rotation on tibial rotation in total knee arthroplasty
    Sherwood, CP
    Zhang, AX
    Petrella, AJ
    Miller, MC
    Berger, RA
    Rubash, HE
    PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 311 - 312
  • [3] Internal Rotation of the Tibial Component is Frequent in Stiff Total Knee Arthroplasty
    Bedard, Martin
    Vince, Kelly G.
    Redfern, John
    Collen, Stacy R.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (08) : 2346 - 2355
  • [4] Femoral and tibial component rotation in total knee arthroplasty METHODS AND CONSEQUENCES
    Scott, R. D.
    BONE & JOINT JOURNAL, 2013, 95B (11): : 140 - 143
  • [5] Correlation of tibial component size and rotation with outcomes after total knee arthroplasty
    Antonio Klasan
    Joshua G. Twiggs
    Brett A. Fritsch
    Brad P. Miles
    Thomas J. Heyse
    Michael Solomon
    David A. Parker
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1819 - 1824
  • [6] Reliability of frames of reference used for tibial component rotation in total knee arthroplasty
    Page, Stephen R.
    Deakin, Angela H.
    Payne, Anthony P.
    Picard, Frederic
    COMPUTER AIDED SURGERY, 2011, 16 (02) : 86 - 92
  • [7] A new landmark for measuring tibial component rotation after total knee arthroplasty
    Mahmood, Fand F.
    Holloway, Nicholas J.
    Deakin, Angela H.
    Clarke, Jon V.
    Picard, Frederic
    KNEE, 2019, 26 (03): : 779 - 786
  • [8] Correlation of tibial component size and rotation with outcomes after total knee arthroplasty
    Klasan, Antonio
    Twiggs, Joshua G.
    Fritsch, Brett A.
    Miles, Brad P.
    Heyse, Thomas J.
    Solomon, Michael
    Parker, David A.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (11) : 1819 - 1824
  • [9] Cementing the Tibial Component in Total Knee Arthroplasty
    Vanlommel, Jan
    Luyckx, Jean Philippe
    Labey, Luc
    Innocenti, Bernardo
    De Corte, Ronny
    Bellemans, Johan
    JOURNAL OF ARTHROPLASTY, 2011, 26 (03): : 492 - 496
  • [10] Medial parapatellar approach leads to internal rotation of tibial component in total knee arthroplasty
    Schiapparelli, Filippo-Franco
    Amsler, Felix
    Hirschmann, Michael T.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (05) : 1564 - 1570