Wavelet modulus maxima method for on-line wavelength location of pulsed lidar in CO2 differential absorption lidar detection

被引:5
|
作者
Gong, Wei [1 ,2 ,3 ]
Xiang, Chengzhi [1 ]
Mao, Feiyue [1 ,2 ,3 ,4 ]
Ma, Xin [1 ]
Liang, Ailin [1 ]
机构
[1] Wuhan Univ, State Key Lab Informat Engn Surveying Mapping & R, Luoyu Rd 129, Wuhan 430079, Peoples R China
[2] Collaborat Innovat Ctr Geospatial Technol, Wuhan 430079, Peoples R China
[3] Hubei Collaborat Innovat Ctr High Efficiency Util, Wuhan 430068, Peoples R China
[4] Wuhan Univ, Sch Remote Sensing & Informat Engn, Luoyu Rd 129, Wuhan 430079, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金; 美国国家科学基金会;
关键词
CARBON-DIOXIDE; MIXING-RATIO; 1572; NM; SENSITIVITY; TRANSFORM; LASER; STABILIZATION;
D O I
10.1364/PRJ.4.000074
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Differential absorption lidar (DIAL) is an excellent technology for atmospheric CO2 detection. However, the accuracy and stability of a transmitted on-line wavelength are strictly required in a DIAL system. The fluctuation of a tunable pulsed laser system is relatively more serious than that of other laser sources, and this condition leads to a large measurement error for the lidar signal. These concerns pose a significant challenge in on-line wavelength calibration. This study proposes an alternative method based on wavelet modulus maxima for the accurate on-line wavelength calibration of a pulsed laser. Because of the different propagation characteristics of the wavelet transform modulus maxima between signal and noise, the singularities of a signal can be obtained by detection of the local modulus maxima in the wavelet transform maximum at fine scales. Simulated analysis shows that the method is more accurate than the general method such as quintic polynomial fitting and can steadily maintain high calibration precision at different signal-to-noise ratios (SNRs). Last, 16 groups of real experiments were conducted to verify the simulated analysis, which shows that the proposed method is an alternative for accurately calibrating an on-line wavelength. In addition, the proposed method is able to suppress noises in the process of wavelength calibration, which gives it an advantage in accurate on-line wavelength calibration with a low SNR. (C) 2016 Chinese Laser Press
引用
收藏
页码:74 / 83
页数:10
相关论文
共 50 条
  • [31] On-line wavelength calibration of pulsed laser for CO2 DIAL sensing
    Ge Han
    Wei Gong
    Hong Lin
    Xin Ma
    Chengzhi Xiang
    Applied Physics B, 2014, 117 : 1041 - 1053
  • [32] Development of Differential Absorption Lidar (DIAL) for Detection of CO2, CH4 and PM in Alberta
    Wojcik, Michael
    Crowther, Blake
    Lemon, Robert
    Valupadas, Prasad
    Fu, Long
    Leung, Bonnie
    Yang, Zheng
    Huda, Quamrul
    Chambers, Allan
    ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES XII, 2015, 9486
  • [33] Chemical detection results from ground testing of an airborne CO2 differential absorption lidar system
    Senft, DC
    Fox, MJ
    Hamilton, CM
    Richter, DA
    Higdon, NS
    Kelly, BT
    Babnick, RD
    Pierrottet, DF
    AIR MONITORING AND DETECTION OF CHEMICAL AND BIOLOGICAL AGENTS II, 1999, 3855 : 144 - 156
  • [34] Remote Measurement of Chemical Warfare Agents by Differential Absorption CO2 Lidar
    Geiko P.P.
    Tikhomirov A.
    Optical Memory and Neural Networks, 2011, 20 (1) : 71 - 75
  • [35] Differential absorption lidar for volcanic CO2 sensing tested in an unstable atmosphere
    Queisser, Manuel
    Burton, Mike
    Fiorani, Luca
    OPTICS EXPRESS, 2015, 23 (05): : 6634 - 6644
  • [36] Operating range of a differential-absorption lidar based on a CO2 laser
    Ivashchenko, MV
    Sherstov, IV
    QUANTUM ELECTRONICS, 2000, 30 (08) : 747 - 752
  • [37] Analysis of energy monitoring for a double-pulsed CO2 integrated path differential absorption lidar at 1.57 μm
    Hu, Wenyi
    Liu, Jiqiao
    Zhu, Yadan
    Dong, Junfa
    Ma, Xiuhua
    Li, Shiguang
    Zhang, Junxuan
    Zhu, Xiaopeng
    Chen, Weibiao
    APPLIED OPTICS, 2019, 58 (03) : 616 - 625
  • [38] Airborne 2-micron double-pulsed integrated path differential absorption lidar for column CO2 measurement
    Singh, Upendra N.
    Yu, Jirong
    Petros, Mulugeta
    Refaat, Tamer F.
    Remus, Ruben G.
    Fay, James J.
    Reithmaier, Karl
    LIDAR TECHNOLOGIES, TECHNIQUES, AND MEASUREMENTS FOR ATMOSPHERIC REMOTE SENSING X, 2014, 9246
  • [39] Detection and classification of atmospheric aerosols using multi-wavelength CO2 lidar
    Warren, Russell E.
    Vanderbeek, Richard G.
    CHEMICAL AND BIOLOGICAL SENSING VIII, 2007, 6554
  • [40] A ground-based differential absorption lidar for atmospheric vertical CO2 profiling
    Han Ge
    Gong Wei
    Ma Xin
    Xiang Cheng-Zhi
    Liang Ai-Lin
    Zheng Yu-Xin
    ACTA PHYSICA SINICA, 2015, 64 (24)